DATA SHEET
カタログの1ページ目を開く- The Aeroleaf and the solar Petal - General Specifications - Electrical Specifications 3. Installation - General Principle - Electrical Connection 4. Summary APPENDIX WindBush anchor
カタログの2ページ目を開くThe Windbush is composed of 12 Aeroleaf equiped with solar petal mounted on 4 trunks connected to each other. The set up has been optimized to collect as much wind and sun power as possible. This hybrid solution is a first in the world. The Windbush becomes very relevant in sunny sites without much oen area. The Windbush can be installed in rows,, in alleys or borders or simply in your backyard. Installed Power Capacity: 4200 W Number of Aeroleaf : 12 Number of Petal PV : 16 Maximum Power per Aeroleaf : 300 W Nominal Power per petal : 36 Wc Elegantly designed and modestly sized, The...
カタログの3ページ目を開くN e w Wo r l d W i n d o ff e r s n o w a h i g h performance photovoltaic Petal in order to add a second source of power to the Aeroleaf. The Petal is positioned at the bottom of each leaf and provides up to 36 Wc to be added to the 300 W from the Aeroleaf. . NWW Micro Generator Proprietary technology with electronic regula>on card embedded in each leaf for a maximum efficiency Monocrystalline semi-flexible film mounted on the petal Each petal has 23 cells for an area of 0.3 m2. That is more 4,8 m2 of photovoltaic area per Windbush. The solar Petal is light and thin (800g and 3mm). Besides, it...
カタログの4ページ目を開くGen eral spec ificat ions Power curve by Aeroleaf (without petal) Voltage / Power / Rota>on speed
カタログの5ページ目を開くThe power produced by the photovoltaic Petals is added to the Aeroleaves electric bus. The electricity is routed through each branch to the control cabinet. The power sum is made through the Inverter. New World Wind provides an electrical cabinet compliant with the electrical standards in France/Europe. We will comply to your country requirements. The Electrical cabinet is made of: • A battery, allowing to temporarily regulate the electricity production to limit peaks and solely for short time needs. It is not for storage. • A specific inverter dedicated to self-consump>on that connects...
カタログの6ページ目を開くInstallation can be carried out by NWW teams or by the customer, subject to compliance with the recommendations established by NWW. . The Installation requires a lifting mechanism of 12 m span to position the Aeroleaves and the solar Petals at the end of each branch. The client shall however prepare: - Earthworks - Small concrete block (according to attached appendix) - The trench + Installation of sleeves between the Windbush and the electrical cabinet (20 meters max) - Grounding the Aeroleaf - The Anchoring base for the electrical cabinet (if needed) A security perimeter of 8 meters...
カタログの7ページ目を開くThe Windbush is based on the concept of on---site generation and self consumption of the electricity in the connected building/area. NEW WORLD WIND Electrical cabinet surge arrester CLIENT Customer facili>es differen>al circuit breaker ba]eries SCHEMATIC OF ELECTRIC INSTALLATION The Windbush is connected to the local grid through the NewWorldWind electrical cabinet. A dedicated space should be prepared for the cabinet, within a maximum distance of 20 meters. In addition to the WindTree and its electrical cabinet, NewWorldWind is also providing the electrical wires between the WindTree and...
カタログの8ページ目を開くSUM MAR Y MECHANICAL SPECIFICATIONS Height Diameter Windbush Height Aeroleaf Total Weight Number of Aeroleaves AEROLEAF SPECIFICATIONS Starting speed Maximum Power per Aeroleaf Maximum Wind PETAL SPECIFICATIONS Power per solar Petal Total photovoltaic power per Bush Solar petal weight (support + photovoltaic film) ELECTRICAL SPECIFICATIONS Installed capacity Voltage required Inverter voltage output SITE INSTALLATION Installation Timeframe Maximum Distance between the Windbush and the electrical Cabinet from 1 to 2 days depending on the site 20 m
カタログの9ページ目を開くRESPONSIBILITIES Preparation of underground Sleeves Earthworks + small concrete block Client Client Installation of the Windbush and Aeroleaves Installation of the Electrical Cabinet Connection between the Windbush and the electrical cabinet Connection between the NWW cabinet and the customer facilities New World Wind Client - The Windbush doesn’t require a declaration of site works under the French standards, other local regulations would have to be respected - simplicity of implementation - Possibility to mount the Bush yourself (subject to NWW recommendat