カタログの抜粋

AIR CURTAINSOVERVIEW CHARACTERISTICS XLF SERIES Overview The door air curtain XLF allows the effective separation of two adjacent areas with different climatic conditions, typically: interior and exterior environments of the tertiary sector. It is particularly suitable for installation in shopping centers, banks, hotels, office buildings, conference rooms, restaurants, etc.. T echnical charatteristics Maximum installation height from 4 up to 5 m Available lengths1.0, 1.5, 2.0 2.5 m Color white RAL 9010 Versions with hating coil electrica or by water Regulation of the air flow:3 speeds SM version manual control 2 level electrical resistance control door opening contact connection DM version wireless connection manual control one external control control electrical resistance at two levels control water coil on / off + valve ZV3 connection with contact of opening doors connectable to the room thermostat off delay door closing DA version manual / automatic control more external controls control electrical resistance at three levels control water coil mixing + valve MV3 connection contact opening doors internal and external temperature sensors * indicative value, valid only in the absence of transverse currents of air through the door
カタログの1ページ目を開く
OVERVIEW CHARACTERISTICS Value refers to the maximum range of the fans, the maximum power of the heater and air inlet temperature 18 ° C
カタログの2ページ目を開く
AIR CURTAINS CONTROL SYSTEMS
カタログの3ページ目を開く
AIR CURTAINS WATER HEATING XLF SERIES Water exchanger parameters for water temperature gradient of 90/70 °C Temperature of intake air: +18 °C 1 KPa = 102 mm water column
カタログの4ページ目を開く
DK-1, Door contact for barriers with control DM DS, Door contact for barriers with control SM - RF TER-P, Room thermostat SH-TM-848, Timer with a weekly program Wall mounting bracket Bracket designed for mounting the air curtain to the wall. 1 Bracket 2 Hanging strip 3 Securing screw VCS4-KONZ-STR set for B and C air curtains (2 pcs.) wall mounting bracket Ceiling holder The holder is designed for attaching the air curtain to a ceiling 1 Ceiling bracket 2 2 Hanging strip 3 3 Securing screw VCS4-KONZ-STR set for B and C air curtains (2 pcs.) ceiling holder
カタログの5ページ目を開く
Valve V135-3 / 4B with capillary The thermostatic valve V135-3 / 4B regulates the flow diverting water to the coil or to the return circuit in the boiler, depending on the temperature detected from the capillary outlet of the coil. The housing of the valve capillary is located after the water coil. Necessary to install a valve for each curtain ZV3 Valve with servo motor The three-way valve ZV3 with actuator receives the signal from the room thermostat TER-P; the valve channels water to the coil or to the return circuit in the boiler in function of ambient temperature. Necessary to install a...
カタログの6ページ目を開くMP3のすべてのカタログと技術パンフレット
-
UV SERIES
6 ページ
-
FLEXIBLE DUCTS
18 ページ
-
floor diffusers
30 ページ
-
AT-RPR Series
7 ページ
-
TT Series
6 ページ
-
SA2 Series
5 ページ
-
SAC Series
5 ページ
-
XRC Series
26 ページ
-
XXP Series
4 ページ
-
XTE Series
2 ページ
-
AS-TN Series
6 ページ
-
XZO Series
4 ページ
-
XE Series
2 ページ
-
XZJ Series
2 ページ
-
XSR Series
4 ページ
-
FTR Series
2 ページ
-
PP 30F Series
4 ページ
-
FA Series
2 ページ
-
FP
1 ページ
-
FTF
2 ページ
-
XUM
4 ページ
-
XLA-C
2 ページ
-
VENTILATION GRILLES
24 ページ
-
diffusion
30 ページ
-
VAV and CAV
82 ページ
-
Regulation
38 ページ
-
Air curtain barrier
42 ページ
-
floor diffusers
22 ページ
-
Recuperators
26 ページ
-
Air-curtain barrier
18 ページ
-
Humidifiers
6 ページ
-
Fans
58 ページ
-
Silenciers
20 ページ
-
Filtering
26 ページ
カタログアーカイブ
-
silencers
20 ページ
-
VAV & CAV
48 ページ
-
diffusion
132 ページ
-
regulation
20 ページ
-
fire protection
12 ページ
-
air-curtain barriers
10 ページ
-
fans
32 ページ
-
humidification
4 ページ
-
recuperators
6 ページ