Description GE Premium 3 is a ventilation unit consisting of a counter current heat exchanger, a heat pump, supply and extract air fans, F7 supply air filter, G4 extract air filter, complete Optima 300 automatics, control panel and comfort cooling option. GE Premium 3 can be delivered with the following options: -- Water or electrical reheater for Ø200 mm duct -- Water frost sensor for water reheater -- Thermostat or motor valve for water reheater -- Electrical preheater for Ø200 mm duct -- Summer box GE Premium 3 is suitable in ventilation systems where balanced ventilation, heat recovery and warm/cool supply air is needed. At first the heat will be recovered in the counter current heat exchanger and then further heat or cooling will be supplied to the supply air by the heat pump. During the summer the heat pump can switched to a cooling mode which means that the heat pump will supply comfort cooling to the supply air. GE Premium 3 can deliver an air volume of up to appr. 550 m3/h at an external pressure of 100 Pa. Types GE Premium 3 - H (right hand) & V (left hand) Dimensions GE Premium 3 Dimension in mm. HØJREVENDT AGGREGAT SET FORFRA UDEN FRONTLÅGE 233 07. Extract air fan 08. Filter, extract air 7: Filter, supply air 09. Udsugningsventilator 8: Udsugningsfilter 10. Friskluftfilter 9. Compressor 11. Kompressor 10: Evaporator 12. Fordamper 11: Condensator 12: Kondensator 01. Fresh air Ø200 02. Exhaust air Ø200 1: Extract 03. Frisk luft air Ø200 2: Supply air Ø200 04. Afkast luft (fraluft) 3: Udsugning 05. Indblæsning (tilluft 4: Counter current heat exch. 06. Modstrømsvarmeveksler 5: Supply air fan 6: Indblæsningsventilator 13. High-pressure gov. 14. Process valve 13: 15. Cable entry Højtykspressostat 14: 16. Electrical box Procesventil 15: Kabelindføring 16: 17. Condensat.conn. Ø15 El-kasse 17: 18. Condensation tubs Kondensvandsafløb Ø15 18: Kondensvandsbakker 19. Supply boss, back Ø100 20. Switch 19: Indblæsningsstuds bagud 21. Magnetic valve defrosting 20: Afbryder 22. Thermovalve condenser 21: Magnetventil afrimning 23. Thermovalve evaporater 22: Termoventil kondensator 24. Sensor for extract 23: Termoventil fordamper air 24: Føler udsugning 25. Sensor for fresh air 26. Sensor for supply air 25: Føler friskluft before cooling coil 27. Sensor 26: Føler indblæsning 28. Sensor for cooling coil 27: Føler før køleflade 29. Sensor for 28: Føler køleflade exhaust air 30. Four-way valve 29: Føler afkast 30: 4-vejs ventil OR Subject to technical modifications of GE Premium 3 datasheet
カタログの1ページ目を開く
Technical data Control panel Electrical connections (Input power supply): Without electrical heating and preheating coil 1 x 230V + N + PE + 10 A, 50 Hz With electrical heating and preheating coil Max 1.2 + 1.0 kW 1 x 230V + N + PE + 16 A, 50 Hz Fans: R3G 220AE 50 Motor: EC motor with integrated electronics Insulation class (fans): B Fan protection class: IP 44 Fan speed (Max. per motor): 3510 Rpm Fan power input (Max. per motor): 157W Fan current (Max. per motor): 0.10 A Fan speed regulation: Individually the fans can be set to 3 different speeds The working area of the heat pump:...
カタログの2ページ目を開く
Size: (h x l x d) ex. connecting pieces and electric box 600 x 1186 x 735 mm GE Premium 3’ capacity varies with air quantity and outdoor air temperature Cabinet: Fully closed hot galvanised plate with 30 mm Isolation. Plastic-coated white RAL 9010. GE Premium 3 VPC - kapacitet v. luftmængde 395 Duct connection: Ø200 mm with rubber ring seal Front: Front with quick locks for filter service Heat exchanger: See water resistant aluminium [W] Condensation tub: Stainless steel Condensation connection: Stainless steel Ø15 mm Filters: Fresh air: F7 filter Exhaust air: G4 filter Udetemperatur [°C]...
カタログの3ページ目を開く
The capacity lines are based on an average of the supply and extract air volume in a unit with filters Total power consumption For both fans and control. 1 = 100 % 2 = 85 % 3 = 70 % 3 = 50 % 4 = 40 % Heat recovery rate Heat recovery rate, flow min = mout Icing of the heat exchanger at low outdoor temperatures has been left out of account. 01. = Temp: RF.: Temperature efficiency (%) våd temperaturvirkningsgrad (den kolde side) Subject to technical modifications of GE Premium 3 datasheet
カタログの4ページ目を開くGenvexのすべてのカタログと技術パンフレット
-
COMBI 185 BP
6 ページ
-
ECO 400 2022
6 ページ
-
ECO 375
6 ページ
-
ECO 360 R
6 ページ
-
ECO 275
6 ページ
-
ECO 190 XL
6 ページ
-
VANVEX R + / RS +
52 ページ
-
GENVEX CONNECT
2 ページ
-
ELECTRIC DUCT HEATER
2 ページ
-
ELECTRIC PREHEATER
3 ページ
-
GES Energy M
3 ページ
-
GE Energy 2
3 ページ
-
GE Energy 3
3 ページ
-
GES Premium 1/1L
4 ページ
-
GE Premium 1/1L
4 ページ
-
Premium Preheat 300
4 ページ
-
Premium Preheat 500
4 ページ
-
Vanvex 185/S 285/S
2 ページ
-
Vanvex R
3 ページ
-
Vanvex RS
3 ページ
-
GS-4
3 ページ
-
GE Premium 2
4 ページ
-
GES Premium 1/1
4 ページ
-
GE Energy 1
3 ページ
-
GES Energy S
3 ページ
カタログアーカイブ
-
ECO 400 2019
20 ページ