カタログの抜粋
Installation manual Matrix 800/400 I,II,III Matrix 1050/400 I,II,III Matrix 1300/400 I,II,III ENG
カタログの1ページ目を開くInstallation manual MatriX 800-1050-1300/400 I,II,III *With non-combustible materials and ventilated chimney breast. * With non-combustible materials and ventilated chimney breast *With non-combustible materials and ventilated chimney breast
カタログの2ページ目を開くInstallation manual MatriX 800-1050-1300/400 I,II,III
カタログの3ページ目を開くInstallation manual MatriX 800-1050-1300/400 I,II,III
カタログの4ページ目を開くInstallation manual MatriX 800-1050-1300/400 I,II,III
カタログの5ページ目を開くInstallation manual MatriX 800-1050-1300/400 I,II,III
カタログの6ページ目を開くInstallation manual MatriX 800-1050-1300/400 I,II,III
カタログの7ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III 1 Dear user Congratulations on your purchase of a Faber fire! A quality product from which you will experience warmth and atmosphere for many years. We recommend that you read this manual carefully before using the fireplace. If any problem arises despite our strict quality control, you can always contact your dealer or Glen Dimplex Benelux B.V. For any warranty claims, it is essential you first register your fireplace. During this registration, you'll find all information regarding our warranty. > Please note! The details of your...
カタログの8ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III 3.1 Appliance • This appliance may not be installed in a chlorine-containing environment. (Pools etc.) • This appliance must be built into an existing or new false chimney. • For transport reasons, for appliances with flexible gas pipes, the control unit (Fig. 1.3) is mounted at the bottom of the crate. Detach and mount it together with the Control box and Remote access door in as low as possible position in the false chimney. (see supplied instruction manual, 40011721). (To prevent damage to cables and pipes during transport, they are...
カタログの9ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III 4.1 Gas connection The gas connection must comply with the applicable local standards. > Please note! • Provide a flexible gas connection with at least 0,5m extra length, so that the control unit can be removed for installation and service! • Calculate the gas pipe so that no pressure drop occurs. We advise using a gas connection directly from the gas meter to the appliance, with a shut-off valve in the proximity of the appliance, which must always be freely accessible. Position the gas connection so that it is easily accessible for...
カタログの10ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III Ventilation Correct ventilation prevents damaging overheating of the gas regulator block and its electronics and also limits the temperature of the convection air. Use the supplied Faber ventilation grids or a similar alternative with a minimum free passage of 200cm2 per grid, in the space above the fire, when building the false chimney. Within the false chimney, a horizontal screen plate, made of noncombustible material, must be installed just above the ventilation openings. (see A in fig. 1.0, 1.1 or 1.2) Installation and finishing >...
カタログの11ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III 5.2 Side glass For cleaning only it's not necessary to remove the side glass. Matrix II and III: • Remove the front glass (chapter 5.1) • Remove the glass strip at the top (fig. 3.6 and 3.7). • Place a suction cup and remove the side glass (fig. 3.8). For replacing the glass repeat the steps in reverse order. > Please note! Avoid fingerprints on the glass; these are no longer removable once the fire is used. 6 Placing decoration material > Please note! • Place the supplied ionization cover at the burner (see fig. 4a, b and c). • Place the...
カタログの12ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III 7.1 Checking the flame image Let the fireplace burn for at least 20 minutes at highest setting and check the flame for: • flame distribution; • colour of the flames. If one or both points are not acceptable then check: • The position of the logs and/or the amount of chips/glass granulates. • The pipe connections for leaks. (in case of blue flames); • That the correct flue restrictor is fitted (see fig. 1.6-F); • The outlet: o Wall terminal has the correct position and side up; o Roof terminal has the correct position. • If the maximum...
カタログの13ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III 10 Conversion to other gas types This can only be done by replacing the burner. To do so, please contact your dealer. Always provide the type and serial number of the appliance when ordering. 11 Flue calculation A simple way to calculate whether the exhaust configuration is possible in combination with your fireplace, use the "Faber Flue App V2": This is available free of charge and can be downloaded via: Internet: Android and PC (Windows Store, (Windows 10)). App Store: iPhone, iPad and Mac. Google Play: Android smart phones and Android...
カタログの14ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
カタログの15ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
カタログの16ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
カタログの17ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
カタログの18ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
カタログの19ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
カタログの20ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
カタログの21ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III Start length (STL) Vertical (TVH) and Horizontal (THL)
カタログの22ページ目を開くInstallation manual Matrix 800-1050-1300/4001,II,III
カタログの23ページ目を開くInstallation manual MatriX 800-1050-1300/400 I,II,III 13 Calculation sheet Starter length (STL) First part on top of the appliance Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m Flue length from 1,5m till 2m Flue length 2m or more Roof terminal Wall terminal Total Vertical Height (TVH) measured height rounded value Total Horizontal Length (THL) Calculation Part Total Length in meters 90° Bend, vertical to horizontal 45° Bend, vertical to horizontal 90° Bend in horizontal direction 45° Bend in horizontal direction flue pipes at an angle in...
カタログの24ページ目を開くFaberのすべてのカタログと技術パンフレット
-
MATRIX 800-500 ST
2 ページ
-
Skive
1 ページ
-
Faber Brochure_Gas_21-22
132 ページ
-
Gas fires
51 ページ
-
special wood
8 ページ
-
special outdoor
8 ページ
-
faber collection 2013
86 ページ
カタログアーカイブ
-
SPECIAL GAS 2010
4 ページ
-
THE BUZZ 2010
2 ページ
-
Special Gas 2009-2010
54 ページ
-
Special Wood 2009
7 ページ