OMNIZONE? 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps
1 / 80ページ

{{requestButtons}}

カタログの抜粋

OMNIZONE? 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps - 1

Product Data OMNIZONE™ 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizoneBWLogo Omnizone 50BV units offer: • Available with R-22 or Puron® (R-410A) refrigerant • Modular units break down to fit through a standard, 36-in. doorway • Either two or four high-efficiency scroll compressors for efficient part load control, quiet operation and system redundancy • Suction and discharge Schrader valves on manifold gage connections Features/Benefits a50-7409ef Omnizone 50BV units are self-contained, water-cooled indoor cooling units, remote air-cooled units, or water source heat pumps. 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE UNIT Flexible, efficient and economical ASHRAElogo a50-74010ef 50BVT,U,V,W,X034-064 MODULAR OMNIZONE UNIT Copyright 2008 Carrier Corporation Units are available for either constant volume (CV) or variable air volume (VAV) applications (with the exception of heat pumps) in both modular and single-piece construction. Single-piece units are completely factory wired, piped and charged, ready for installation. Units with Puron refrigerant have EERs up to 14.8, while units with R-22 have EERs up to 14.6. Units include a direct expansion evaporator coil, compressors, and watercooled cleanable condensers (unless remote air-cooled). The VAV units include a single or multiple belt drive evaporator fan(s) with VFD (variable frequency drive) controlled motor and complete microprocessor control system. Optional water economizers and hot water heating may also be added. Form 50BV-4PD

カタログの1ページ目を開く
OMNIZONE? 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps - 2

Features/Benefits (cont) These vertical package units offer flexible economical air conditioning for today’s office environment. Compressors are mounted on vibration isolators. Each compressor is equipped with a coaxial tube-in-tube condenser for maximum heat transfer efficiency and performance. All condensers are rated at 450 psig operating refrigerant pressures (600 psig for Puron® refrigerant models) and 400 psig water-side pressures. Evaporators are enhanced fin, rifled tube type for maximum performance. Large face areas ensure low airside pressure drops and reduced face velocities to...

カタログの2ページ目を開く
OMNIZONE? 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps - 3

Model number nomenclature A/C CV VAV W/C — — — — LEGEND Air-Cooled Constant Volume Variable Air Volume Water-Cooled *Refer to 50BV price pages or contact your local Carrier representative for a list of factory-installed options. †BVC,E,Q may select -, B, C, or D; 50BVT,U,V may select D or E; 50BVJ,K may select C only, 50BVW,X may select E only; 50BVT, U,W,X,V (low-boy) may select C or D only. **Horsepower ratings are per motor. Most 50BV units have two indoor-fan motors. See price pages for additional information. a50-8234 3

カタログの3ページ目を開く
OMNIZONE? 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps - 5

Physical data — 50BVC,E,J,K,Q units UNIT 50BVC,E,J,K,Q NOMINAL CAPACITY (Tons) SHIPPING WEIGHT (lb) 50BVC,Q…50BVJ 50BVE…50BVK COMPRESSOR Quantity Number of Refrigerant Circuits Oil (ounces) Ckt 1…Ckt 2 REFRIGERANT TYPE Expansion Device Operating Charge (lb) Ckt 1…Ckt 2 CONDENSER (50BVC,Q,J only) Quantity of Manifolded Circuits Nominal Flow Rate (GPM) Water Flow Range (GPM) Max. Water Working Pressure (PSIG) Max. Refrig. Working Pressure (PSIG) Min. Entering Water Temp. (F) Max. Entering Water Temp. (F) Waterside Volume (gal) EVAPORATOR COIL Rows…Fins/in. Total Face Area (sq ft) EVAPORATOR...

カタログの5ページ目を開く
OMNIZONE? 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps - 7

Factory-installed options Waterside economizer — A condenser water pre-cooling coil located before the direct expansion cooling coils allows the use of the condenser water to provide free cooling. When the condenser water temperature is less than an adjustable set point or more below the return-air temperature, condenser water is directed to the economizer coil to obtain free cooling. When free cooling is available the economizer coil functions as the first stage of cooling. The economizer coil valve can be modulated to control discharge-air temperature when the economizer can meet or...

カタログの7ページ目を開く
OMNIZONE? 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps - 8

Dimensions 50BVC,J,Q020-034 NOTES: 1. Dimensions in inches [mm]. 2. VAV models (50BVJ) are rear return, top supply only. 3. Compressor, controls, and condenser access are through front panels. 4. Field power connections are 1-3/4 inches. Control connections are 7/8 inches. 5. Optional blower orientation is selected in model number nomenclature as option 9 in FIOP section (digits 15 and 16). Shows recommended minimum service clearances. OPTIONAL BLOWER ORIENTATION STANDARD BLOWER ORIENTATION OPTIONAL BLOWER ORIENTATION STANDARD BLOWER ORIENTATION a50-8199 8

カタログの8ページ目を開く
OMNIZONE? 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps - 9

50BVE,K020-034 NOTES: 1. Dimensions in inches [mm]. 2. VAV models (50BVK) are rear return, top supply only. 3. Compressor, controls, and condenser access are through front panels. 4. Field power connections are 1-3/4 inches. Control connections are 7/8 inches. 5. Discharge (hot gas) connections are 1-1/8 in. OD. 6. Liquid line connections are 7/8 in. OD. 7. Optional blower orientation is selected in model number nomenclature as option 9 in FIOP section (digits 15 and 16). RECOMMENDED CONDENSER MATCHES: 50BV020 one (1) 09DK020 (50/50 split each) 50BV024 one (1) 09DK024 (50/50 split each)...

カタログの9ページ目を開く
OMNIZONE? 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps - 10

Dimensions (cont) 50BVT,V,W034 (High-Boy) 69.50 SHIPPING SECTION 2.00 65.50 2.00 2.88 BLOWER SECTION ACCESS BLOWER SECTION ACCESS 31.00 STANDARD DISCHARGE EVAPORATOR ACCESS 54.75 54.38 81.50 80.00 3.75 15.00 COMPRESSOR ACCESS 13.00 10.75 8.75 5.00 LIFTING SUPPORT RAIL 23.25 REAR VIEW RETURN AIR VIEW 51.63 9.88 LEFT SIDE VIEW 49.75 21.75 5.50 18.75 EVAPORATOR ACCESS 23.75 REAR DISCHARGE (Optional) 3.19 EVAPORATOR ACCESS FILTER ACCESS ECONO COIL (Optional) DIRECT EXPANSION EVAPORATOR COMPRESSOR ACCESS 1.50 D A C NOTES: 1. Dimensions in inches [mm]. 2. All units are rear return airflow...

カタログの10ページ目を開く
OMNIZONE? 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps - 11

50BVT,V,W034 (Low-Boy) STANDARD DISCHARGE BLOWER SECTION ACCESS EVAPORATOR ACCESS ELECTRICAL COMPRESSOR ACCESS LIFTING SUPPORT RAIL FILTER ACCESS FRONT DISCHARGE (OPTIONAL) ECONO COIL (OPTIONAL) DIRECT EXPANSION EVAPORATOR REHEAT COIL (OPTIONAL) BLOWER SECTION ACCESS FILTER ACCESS ECONO COIL (OPTIONAL) DIRECT EXPANSION EVAPORATOR EVAPORATOR ACCESS REHEAT COIL (OPTIONAL) WATER IN (ECONO COIL OPTIONAL) D C B A CONNECTIONS A WATER OUT 2-1/2 in. FPT B WATER IN 2-1/2 in. FPT C CONDENSATE DRAIN 1-1/4 in. FPT D ECONOMIZER DRAIN 1-1/4 in. FPT REPLACEMENT FILTERS : EIGHT (8) AT 17 x 27 x 4 INCHES....

カタログの11ページ目を開く

CARRIER commercialのすべてのカタログと技術パンフレット

  1. 40UV-UH-14SI

    32 ページ

  2. 42B-6SI

    24 ページ

  3. A WORLD OF COMFORT

    20 ページ

  4. A World of Comfort

    2 ページ

  5. 19DV

    32 ページ

  6. 30XA

    136 ページ

  7. 30RAP

    104 ページ

  8. Carrier VRF

    44 ページ

  9. A World of Comfort

    2 ページ

  10. ComfortVIEW 3

    6 ページ

  11. VVT Zoning System

    8 ページ

  12. Comfort? Series

    2 ページ

  13. GEMINI? 38AKS028-044

    40 ページ

カタログアーカイブ