カタログの抜粋

:DEN THE BELDEN BRICK COMPANY THE FOUNDATION TO BUILD YOUR NEXT MASTERPIECE
カタログの1ページ目を開く
TECHNICAL DATA - BELDEN THRU-WALL UNITS RVALUE 6 INCH THRU-WALL 8 INCH THRU-WALL Hollow ASTM C 652 R =. 95 Hollow ASTM C 652 R = 1.10 These two values are calculated using the dual path procedure outlined in Brick Industry Association (BIA) Technical Notes 4. (Path A was through the face shells and webs, Path B was through the face shells and cells. A weighted average was then determined for each path Higher value may be obtained by calculating the walls' U-Value, taking into account outside and inside air films. STC RATING 6 INCH THRU-WALL 8 INCH THRU-WALL Unit Weight = 16 lbs. Unit...
カタログの2ページ目を開く
WALL HEIGHT COMPARISONS • Modest Loading • Comparable Grout and Reinforcing From a cost comparison standpoint, we are compar- ing installed costs of various Reinforced Brick Masonry (RBM) and Concrete Masonry Unit (CMU) single wythe systems. In comparing 6" TTW brick and 8" half high CMU, in a days time, a mason and tender will install ap- proximately 350 CMU. In that same time, 365 brick would be installed. Productivity differences are due to unit size and weight. Similar productivity differences by other size TTW Brick in corresponding size CMU are also seen. 6 INCH 8 INCH 8 INCH 12 INCH...
カタログの3ページ目を開く
ISOMETRIC VIEW II I II II II II I II II I_ _ _ _uiii~i~ii~i~ii_ _ _ _~luil~ II II II II III ~~~iiiwi FRONT VIEW TOP VIEW ISOMETRIC VIEW FRONT VIEW 7-5/8" BED BOND BEAM SIDE VIEW
カタログの4ページ目を開く
ISOMETRIC VIEW iiiiiiii ~~----~~~----~~ FRONT VIEW ISOMETRIC VIEW FRONT VIEW 13/4 in [44 mm) 5-5/8" BED BOND BEAM (39.1% VOID) SIDE VIEW
カタログの5ページ目を開く
FRONT VIEW ISOMETRIC VIEW III I II IIII IIII IIII '" FRONT VIEW ISOMETRIC VIEW SIDE VIEW
カタログの6ページ目を開く
FRONT VIEW ISOMETRIC VIEW ISOMETRIC VIEW FRONT VIEW 5-5/8" BED BOND BEAM (39.1% VOID)
カタログの7ページ目を開く
COMPRESSIVE STRENGTH AVERAGE % VOID COMPRESSIVE STRENGTH AVERAGE % VOID COMPRESSIVE STRENGTH AVERAGE % VOID The brick represented by the test results shown here comply with the standards listed below: ASTM C 652 Standard Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale) Grade: SW.MW with absorption alternate in section 5.1.2 :: Class: H60V
カタログの8ページ目を開く
COMPRESSIVE STRENGTH AVERAGE % VOID MOMENT OF INERTIA (I) AND RADIUS OF GYRATION ® TABLE INERTIA PER LINEAR FOOT GYRATION PER LINEAR FOOT MOMENT OF INERTIA (I) AND RADIUS OF GYRATION ® TABLE INERTIA PER LINEAR FOOT GYRATION PER LINEAR FOOT BRICK MASONRY STRENGTH The net compression strength of masonry (f m) can be found in Table 1 of ACI 53.1 (Specification for Masonry Structures) when the compressive strength of the unit and mortar are known. The Thru-Wall units shown in this brochure will have the following f'm values when using Type S mortar. *Strength of the grout will control the F'm...
カタログの9ページ目を開く
Reinforced brick masonry is not a new wall system. Reinforcing steel and grout have been used with brick masonry for over 100 years. With brick masonry's high compressive strength, reinforcing makes for an economical, high- strength wall in comparison to other reinforced masonry systems. DOUBLE MONARCH THRU-WALL Thru-Wall Brick offer: • Greater design flexibility. • Reduced backup requirements. • Reduced number of tie connections, which provides a more continuous moisture barrier. • Greater seismic resistance and more ductility. • Less restrictive deflection requirements of the backup...
カタログの11ページ目を開く
THE BELDEN BRICK COMPANY An ISO 9001:2008 Registered Quality Management System An IS0 14001:2004 Environmental Management System
カタログの12ページ目を開くBelden Brickのすべてのカタログと技術パンフレット
-
Plank Pavers Series
2 ページ
-
Concept Catalog
16 ページ
-
Brick Sculptures
4 ページ
-
Brick Chips
1 ページ
-
Belden Roman Brick
1 ページ
-
Belden Brick History
8 ページ
-
Brick Pavers
12 ページ
-
Thin Brick
24 ページ
-
Landmarks in Brick
5 ページ
-
Sculpture
4 ページ
-
Special Shapes 2012
40 ページ
-
The Great American Home
39 ページ
カタログアーカイブ
-
Pavement catalogue
2 ページ
-
Bricks catalogue
8 ページ