METAL CELLS TRIGON Open cell Trigon: Product not available in France. | Produit non disponible en France. PANELS DIMENSIONS ~693x1386 mm rhomboidal shaped Meshes Open area OPEN CELL ELEMENTS Base 10 H41 interlocking profiles INTEGRATED STRUCTURE Main profiles: 2771,3 mm Spacer: 1380 mm Photo by Damir Kopezhanov on Unsplash |Render Atena S.p.A. OPEN CELL MATERIALS 5/10 Aluminum HANGERS Standard double hanger Ø4 mm with spring 12 WALL ANGLES “C” 25x42x10 mm wall angle with the same material and finishing of the open cell COLORS Atena standard white and silver pre-painted aluminum Wood effect pre-painted aluminum RAL/NCS Post-painting ACCESSORIES Lighting adapters Technical Data Sheet atena s.p.a. has a quality management system certificated by rina in compliance with ISO 9001 ELEMENT QUANTITY PER MODULE 600x1200 PIECES/SQM LM/SQM LOWER ELEMENTS INTERM. ELEMENTS SUPERIOR ELEMENTS * For specific project requirements, the hanger incidence may vary. Please check with the Atena S.p.A technical department. WOOD ATENA RANGE ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 1 of 6 Weights kg/m2, without hanger

カタログの1ページ目を開く
Atena_Trigon_Ds_Eng - 2

ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 2 of 6 TECHNICAL PERFORMANCES FLEXION RESISTANCE Maximum span mm 1200 - 1 Class EN13964 CORROSION RESISTANCE Galvanized steel products: C2 Class Pre-painted galvanized steel products: C3 Class Post-painted galvanized steel products: C4 Class Pre/post-painted aluminum products: C5 Class (RH%) RELATIVE HUMIDITY RESISTANCE Galvanized steel products: ≤ 90% Pre/post-painted galvanized steel products: > 90% Stainless steel and aluminium products: > 90% Wet cloth with warm water and neutral non-abrasive detergents. COLOR...

カタログの2ページ目を開く
Atena_Trigon_Ds_Eng - 3

ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 3 of 6 SECTION VIEW *verify interaxes and hanger models according to the load at m 2 the antiseimic report and particular conditions when required.The fastening must be checked with regard to the loads, the anchoring base features and the installation accuracy, in order not to compromise the stability of the metal ceiling system. Lightings, accessories and systems must not weigh on the metal ceiling system, but must be independently suspended. WALL ANGLE COMPONENT INCIDENCES OPEN CELL PANEL WALL ANGLE - pcs/sqm...

カタログの3ページ目を開く
Atena_Trigon_Ds_Eng - 4

ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 4 of 6 1/2 Draw the lines of the primeter frame. Determine the height of the ceiling with a level and mark it with a string. Install the wall angles with mails, screws and/or plugs suitable to the wall material. 3 Fix the hangers according to the type of ceiling to be installed*. Hook 2771 mm main profiles on the hangers*. Proceeed with the installation of spacers with a 693 mm interaxe. Lay the assembled open cell panels on the structure. *verify interaxes and hanger models according to the load at m 2 the...

カタログの4ページ目を開く
Atena_Trigon_Ds_Eng - 5

ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 5 of 6 CLEANING, MAINTENANCE AND REMOVAL INSTRUCTIONS Cleaning and maintenance require some attention and care even though are easy to make and don’t take much time. It is necessary to use warm water and neutral and non-abrasive detergents. Metal ceilings maintenance usually refers to: placement, alignment or replacement of damaged or broken modules (panels, staves, baffles, open cells) which can be also removed for restoration or maintenence of the system below. In order to ensure an excellent results, the...

カタログの5ページ目を開く
Atena_Trigon_Ds_Eng - 6

ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 6 of 6 NORMATIVE REQUIREMENTS Atena S.p.A. has adopted a quality management system in compliance with the UNI EN ISO 9001 standard. All Atena metal ceilings are produced for indoor applications, in compliance with Technical Standards for Construction NTC 2018 and relative circular requirements, the Minimum Environmental Criteria CAM (Ministerial Decree 11 October 2017), the specific technical standards applicable UNI EN 13964 and 14195. Each Atena S.p.A. product has its own DOP (CE Declaration of Performance)...

カタログの6ページ目を開く

Atena spaのすべてのカタログと技術パンフレット

  1. EXPANDED METAL

    8 ページ

  2. FORMAL

    9 ページ

  3. METAL CELLS

    29 ページ

  4. METAL BAFFLE

    35 ページ

  5. ATENA H+

    27 ページ

  6. BOOK

    43 ページ

  7. Atena Façades

    13 ページ

  8. ATENA ENJOY

    5 ページ

  9. ENIGMA TRIM

    6 ページ

  10. METAL MESH

    47 ページ

  11. HOSPITAL SYSTEMS

    32 ページ

  12. BAFFLE SYNCRO UP

    8 ページ

  13. doghe - grigliati

    41 ページ

  14. vivi

    49 ページ

  15. STEEL STRONG

    21 ページ

  16. Metal Shapes

    79 ページ

  17. Metal Series

    47 ページ

  18. MULTILEVEL 3D cube

    2 ページ

  19. Flexit newsletter

    2 ページ

  20. ATENA EnigmaLink

    7 ページ

  21. Atena Cat Navale

    11 ページ

  22. ATENA ANTISISMICO

    28 ページ

  23. Atena Naval sector

    11 ページ

  24. Atena Metal Sound

    34 ページ

  25. Atena References

    76 ページ

  26. ATENA SILVER SEA

    5 ページ