カタログの抜粋

METAL CELLS TRIGON Open cell Trigon: Product not available in France. | Produit non disponible en France. PANELS DIMENSIONS ~693x1386 mm rhomboidal shaped Meshes Open area OPEN CELL ELEMENTS Base 10 H41 interlocking profiles INTEGRATED STRUCTURE Main profiles: 2771,3 mm Spacer: 1380 mm Photo by Damir Kopezhanov on Unsplash |Render Atena S.p.A. OPEN CELL MATERIALS 5/10 Aluminum HANGERS Standard double hanger Ø4 mm with spring 12 WALL ANGLES “C” 25x42x10 mm wall angle with the same material and finishing of the open cell COLORS Atena standard white and silver pre-painted aluminum Wood effect pre-painted aluminum RAL/NCS Post-painting ACCESSORIES Lighting adapters Technical Data Sheet atena s.p.a. has a quality management system certificated by rina in compliance with ISO 9001 ELEMENT QUANTITY PER MODULE 600x1200 PIECES/SQM LM/SQM LOWER ELEMENTS INTERM. ELEMENTS SUPERIOR ELEMENTS * For specific project requirements, the hanger incidence may vary. Please check with the Atena S.p.A technical department. WOOD ATENA RANGE ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 1 of 6 Weights kg/m2, without hanger
カタログの1ページ目を開く
ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 2 of 6 TECHNICAL PERFORMANCES FLEXION RESISTANCE Maximum span mm 1200 - 1 Class EN13964 CORROSION RESISTANCE Galvanized steel products: C2 Class Pre-painted galvanized steel products: C3 Class Post-painted galvanized steel products: C4 Class Pre/post-painted aluminum products: C5 Class (RH%) RELATIVE HUMIDITY RESISTANCE Galvanized steel products: ≤ 90% Pre/post-painted galvanized steel products: > 90% Stainless steel and aluminium products: > 90% Wet cloth with warm water and neutral non-abrasive detergents. COLOR...
カタログの2ページ目を開く
ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 3 of 6 SECTION VIEW *verify interaxes and hanger models according to the load at m 2 the antiseimic report and particular conditions when required.The fastening must be checked with regard to the loads, the anchoring base features and the installation accuracy, in order not to compromise the stability of the metal ceiling system. Lightings, accessories and systems must not weigh on the metal ceiling system, but must be independently suspended. WALL ANGLE COMPONENT INCIDENCES OPEN CELL PANEL WALL ANGLE - pcs/sqm...
カタログの3ページ目を開く
ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 4 of 6 1/2 Draw the lines of the primeter frame. Determine the height of the ceiling with a level and mark it with a string. Install the wall angles with mails, screws and/or plugs suitable to the wall material. 3 Fix the hangers according to the type of ceiling to be installed*. Hook 2771 mm main profiles on the hangers*. Proceeed with the installation of spacers with a 693 mm interaxe. Lay the assembled open cell panels on the structure. *verify interaxes and hanger models according to the load at m 2 the...
カタログの4ページ目を開く
ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 5 of 6 CLEANING, MAINTENANCE AND REMOVAL INSTRUCTIONS Cleaning and maintenance require some attention and care even though are easy to make and don’t take much time. It is necessary to use warm water and neutral and non-abrasive detergents. Metal ceilings maintenance usually refers to: placement, alignment or replacement of damaged or broken modules (panels, staves, baffles, open cells) which can be also removed for restoration or maintenence of the system below. In order to ensure an excellent results, the...
カタログの5ページ目を開く
ATENA S.p.A. | Technical data sheet Trigon Open cell - rev 0 | 2024 - pag. 6 of 6 NORMATIVE REQUIREMENTS Atena S.p.A. has adopted a quality management system in compliance with the UNI EN ISO 9001 standard. All Atena metal ceilings are produced for indoor applications, in compliance with Technical Standards for Construction NTC 2018 and relative circular requirements, the Minimum Environmental Criteria CAM (Ministerial Decree 11 October 2017), the specific technical standards applicable UNI EN 13964 and 14195. Each Atena S.p.A. product has its own DOP (CE Declaration of Performance)...
カタログの6ページ目を開くAtena spaのすべてのカタログと技術パンフレット
-
EXPANDED METAL
8 ページ
-
FORMAL
9 ページ
-
METAL CELLS
29 ページ
-
METAL BAFFLE
35 ページ
-
ATENA H+
27 ページ
-
BOOK
43 ページ
-
Atena Façades
13 ページ
-
ATENA ENJOY
5 ページ
-
ENIGMA TRIM
6 ページ
-
DRY CONSTRUCTION SYSTEMS
17 ページ
-
METAL MESH
47 ページ
-
HOSPITAL SYSTEMS
32 ページ
-
BAFFLE SYNCRO UP
8 ページ
-
doghe - grigliati
41 ページ
-
vivi
49 ページ
-
STEEL STRONG
21 ページ
-
Metal Shapes
79 ページ
-
Metal Series
47 ページ
-
MULTILEVEL 3D cube
2 ページ
-
Flexit newsletter
2 ページ
-
Atena METAL SOUND Rev01
34 ページ
-
ATENA EnigmaLink
7 ページ
-
Atena Cat Navale
11 ページ
-
ATENA ANTISISMICO
28 ページ
-
ATENA LAMIERA STIRATA
20 ページ
-
ATENA GESSO RIVESTITO
56 ページ
-
Atena Naval sector
11 ページ
-
Atena Special Finishing
16 ページ
-
Atena Metal Sound
34 ページ
-
Atena References
76 ページ
-
Atena Hospital Systems
24 ページ
-
CUSTOM-MADE CLADDINGS
40 ページ
-
Easy Antiseismic System
28 ページ
-
T-BAR LED Smartlight
6 ページ
-
ATENA SILVER SEA
5 ページ