TS - 1

Air handling units with cooling capacity from 4.85 up to 24.8 kW TSMX TS TSBA TSPM Characteristics • Compact unit for horizontal installation • Structure made of Aluzink sheet steel and internally covered with sheets of polyethylene and polyester to obtain improved thermal and acoustic insulation • Condensate drip tray in stainless steel AISI 304 with insulation • Coils with aluminium fins and copper pipes • Statically and dynamically balanced centrifu- gal fans • Wide range of accessories to meet varying • Three-speed electrical motor with running needs (class G3 air filter, post-heating coils, capacitor permanently activated and internal plenum suction assembly, mixer section, sucthermal protection tion grille, delivery flanges with circular • Transmission system relay card for each speed outlets or rectangular outlet) (excluding the models TS13 and TS16) • Useful static pressure available for any canalisation • Large choice of distance commands Choice of Unit By suitably combining the numerous options available, it is possible to configure each model in such a way as to meet the most particular of system requirements. Code: Models Field configurer: TS 1 2 3 4 available: | | | Size: Code | | TS 13 1, 2, 3, 4, 5, 6, 7 | Size | TS 16 Coil: | | Row coil TS 23 3 - 3-row coil | | | TS 34 TS 1 2 3 4 5 6 7 3 4 6 4 - 4-row coil TS 36 TS 43 6 - 6-row coil Example of the commercial code: TS34 This is a TS unit, size 3, with 4-row coil. Accessories • TSBA: 2-row coil for post-heating, contained in which the TSGA grille can be applied the connector (W) of the FMT21 panel. Two a delivery installation plenum • TSPM: Delivery plenum to be connected to the SWA probes can be connected simultaneously • TSFA: Class G3 air filter circular channels (with 2, 3 or 4 circular, 200 to the FMT21 panel. • TSFM: Delivery flange with rectangular section mm flanges). • Control panels:the characteristics of the control • TSGA: Horizontal suction grille with fixed fins • SWA: External probe accessory SWA (length L = panels are described on the appropriate card. to produce suction from below together with 6m). It detects the temperature of the room air if the TSPA accessory connected to the connector (A) of the FMT21 • TSMX: Section that mixes the recirculating air panel. The room air temperature probe, incorand the external air. Calibration of the mix via porated in the panel, is automatically disabled. the damper, motorisation is possible It detects the temperature of the water in the • TSPA: Plenum with suction from below, to system for ventilation consent if connected to TSPA TSRD TSRS

カタログの1ページ目を開く
TS - 2

Model Cooling capacity Sensible cooling capacity Water side pressure drop Water flow rate Heating capacity Water side pressure drop Water flow rate Nominal air flow rate Useful static pressure (1) TSFA filter pressure drop (2) Coil rows Coil water connections Maximum water temperature Ventilation speed number Motors Fans Ventilation speed number Motors Motor maximum power Maximum input current Sound pressure level Power supply = 230V ~ 50Hz. Performance values refer to the following conditions: (1) rated capacity (maximum speed) without air filter; (2) air filter (TSFA accessory) at rated...

カタログの2ページ目を開く

AERMECのすべてのカタログと技術パンフレット

  1. FCZI-D

    5 ページ

  2. FCZ-D

    5 ページ

  3. NRG

    9 ページ

  4. HWF

    4 ページ

  5. WFGI

    9 ページ

  6. WFGN

    7 ページ

  7. WFI

    9 ページ

  8. WFN

    8 ページ

  9. WRL 026 -161

    5 ページ

  10. BHP

    6 ページ

  11. DUALJET

    10 ページ

  12. AERMEC FOR WINE

    20 ページ

  13. ANK

    8 ページ

  14. ANLI

    8 ページ

  15. MGW

    2 ページ

  16. NSI

    4 ページ

  17. TA

    4 ページ

  18. Omnia Radiant

    4 ページ

  19. MHM

    4 ページ

  20. MHW

    2 ページ

  21. Technical Focus

    16 ページ

  22. All product

    404 ページ

カタログアーカイブ

  1. Data sheet - UR

    4 ページ