PRODUKTNAME INSTALLATION SEITENTHEMA 51 51 ing adequate air circulation must be used. When installing KAVA LED (not KAVA LED IP54), the 8 W and 25 W power units (S7 003 150 and S7 003 230) can be placed in combined casting surround S7 709 960 and S7 709 990 to supply com- The group power units and dim-ming converters available as accessories have IP20 protection and are thus only suitable for indoor use. If installed in damp locations or outdoors, installation boxes having the appropriate degree of protection and allow- plete groups of luminaires cen-trally. In addition, the IP67 uni- versal box can also be used to obtain water-tight installation of 8 W and 25 W power units S7 003 150 and S7 003 230.

ORILED

The IP65 versions of ORILED can also be through-wired with 230 V. In case of operation with bus signals, provide one cable gland for the power cable and another for the bus signal. With the IP40 version, it is possible to use a separate gear tray for up to three luminaires to loop the wiring through on the primary side on the actual gear tray. On the secondary side, the lumi- naires must be wired for series connection.

Seepage water and frost resistance Location of power units and dimming converters

Any seepage water must be allowed to drain away in the case of LEDOS, LEDOS B and LEDOS M recessed floor lumi- naires. This requires a 300 mm drainage layer underneath the concrete floor. This also applies to PHAOS LINE recessed lumi- naires and PASO II models in outdoor areas.

LEDOS FLOOR

When using LEDOS recessed floor luminaires, make sure that band, use surrounds S7 709 970 and S7 709 980 where the CLIP connection is replaced by two visible stainless steel screws. The stainless steel frame/ring must be used when installing LEDOS in cavity walls or drive- over areas (e.g. entrances, car parks). the casting surround is accurately positioned in order to allow locking of the CLIP connection between the surround and the stainless-steel frame/ring. If the project makes it impossible to comply with a ±1 mm tolerance
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 51 p.51
page 52 p.52
page 53 p.53
page 54 p.54
page 55 p.55
page 56 p.56
page 57 p.57
page 58 p.58
page 59 p.59
page 60 p.60
page 61 p.61
page 62 p.62
page 63 p.63
page 64 p.64
page 65 p.65
page 66 p.66
page 67 p.67
page 68 p.68
page 69 p.69
page 70 p.70
page 71 p.71
page 72 p.72
page 73 p.73
page 74 p.74
page 75 p.75
page 76 p.76
page 77 p.77
page 78 p.78
page 79 p.79
page 80 p.80
page 81 p.81
page 82 p.82
page 83 p.83
page 84 p.84
page 85 p.85
page 86 p.86
page 87 p.87
page 88 p.88
page 89 p.89
page 90 p.90
Pages:
1-50
51-90
pdf-page pdf ae En 2008-10-41-11