Text version of the page
ORILED 11 >
Because ORILED was designed as a functional luminaire, partic-
ular attention was paid to per-
formance data. The diagram on
the left shows the distribution of
lighting intensity at ground level.
Results show that the require-
ments concerning illuminance
for escape routes according
to EN 1838 are significantly
exceeded – with minimal energy
consumption and maximum
cost-effectiveness. Even retrofit-
ting ORILED in existing projects
is simple thanks to its aluminium
surface-mounted housing. Because of its compact dimen-
sions, for renovation projects
ORILED can also be adapted to
suit existing bays. In case of installation in cavity walls, dimmable and switchable
control gear makes it possible
to form groups of up to three
ORILED luminaires.
Besides its two 1 W LEDs, the secret to ORILED’s excellent illuminance is,
in particular, its PSP+ >
® reflector com-bined with its unique lens optic. Light distribution at ground level >