Catalogue Modular lighting systems- Lightools
www.zumtobel.com
print switch display
Page / 45
Make a request   
ZUMTOBEL -
/ 45
See other catalogues for ZUMTOBEL
Text version of the page

LIGHTTOOLS

L-TOOLS blank section, ceiling-bearing L-TOOLS end-plate set, ceiling-bearing L-TOOLS through-wiring with sockets L-TOOLS feed-in/feed-out unit for through-wiring

Cat. no. W/Hkg Order no.

Blank section unit,with flange (unas-sembled) • For cutting to suit on site (minimumlength 800 mm!) and subsequent assembly to a shortened U-section• Design otherwise as in L-TOOLS section,with flange• Incl.2 end plates with flange,for clo-sure of entire channel end• 1 end plate with fixed 7-pole terminalfor feed-in• Colour:titanium•Width of ceiling cut-out 124 mm,resulting aperture 100 mm

Blank channel section,ceiling-bearing

Length 1,600 mm 134/1757.7 60 210 006

Generally,one blank section is needed at the end of a length of channel and is cut to suit onsite.See formula for determining number of channel sections required on page 16.

Cat. no. kg Order no.

End caps with flange

End-cap set

• For closing both front ends of a ceil-ing-bearing channel length• 1 end plate with fixed 7-pole terminalfor feed-in• Material:extruded aluminium section • Colour:titanium

2 off,with flange 0.3 60 210 007

Only to be ordered if no blank channel sections are used.Therefore required if channel lengthis made up only of standard lengths 1,600 / 800.

Cat. no. kg Order no.

Through-wiring

7 x 1.5 mm

2

through-wiring

• 5 x 1.5 mm

2

für 3-circuit mains supply• 2 x 1.5 mm

Section with total length of approx. 1.6 m 0.4 60 210 010 Loom with total length of approx. 10 m 2.0 60 210 009
2

for bus supply• Incl.7-pole plug-in sockets every 320 mm• Fitted in channel section without useof tools• Through-wiring has to be cut tolength on site

Loom with total length of approx. 25 m 5.0 60 210 008

One additional feed-in/feed-out unit (also as closure) required per end of cut.

Cat. no.Order no.

Feed-in/feed-out unit for through- wiring • Connected on site to ends of through-wiring• For terminating continuous throughwiring or for safe closure of cable end• Plug-in contacts with push-buttonrelease• Feeder cable inserted through open-ing in end-plate

Feed-in/feed-out units (pair)

7-pole 60 210 011

To specify e.g.:L-TOOLS cut-to-length section,ceiling-bearing Length 1,600 mm 60 210 006

ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
pdf-page pdf ae En 2008-10-41-12