Text version of the page
LIGHTTOOLS
L-TOOLS through-wiring with sockets
L-TOOLS feed-in/feed-out unit for through-wiring
Cat. no. kg Order no. >
Throug-wiring
7 x 1.5 mm
2 through-wiring
• 5 x 1.5 mm
2 für 3-circuit mains supply• 2 x 1.5 mm
Section with total length of approx. 1.6 m 0.4 60 210 010 Loom with total length of approx. 10 m 2.0 60 210 009 >
2 for bus supply• Incl.7-pole plug-in sockets every 320 mm• Fitted in channel section without useof tools• Through-wiring has to be cut tolength on site
Loom with total length of approx. 25 m 5.0 60 210 008 >
One additional feed-in/feed-out unit (also as closure) required per end of cut.
Cat. no.Order no. >
Feed-in/feed-out unit for through-wiring • Connected on site to ends of through-wiring• For terminating continuous throughwiring or for safe closure of cable end• Plug-in contacts with push-buttonrelease• Feeder cable inserted through ope-ning in end-plate
Feed-in/feed-out units (pair)
7-pole 60 210 011 >
L-TOOLS cover for through-wiring
Cat. no. kg Order no. >
Cover section for through-wiring
Cover section
• For optional closure of through-wiringon site• Material:grey plastic (titanium colour)
• Can be cut to size as required on siteand snapped into the supporting finsin the base of the channel section
1,600 mm 0.4 60 210 012 >
L-TOOLS steel cord (pair)
Cat. no.Order no. >
Pair of steel cords • For continuous height adjustment andbalancing of channel lengths• For reducing load on suspended ceil-ing,and for directly shifting weight to
load-bearing ceiling structure• Load carrying capacity per steel cord:30 kg• Insert into both spacing brackets ofmounting frames,or snap onto moun-
ting tracks in base of channels sec-
tions with flange• Each with ceiling rose and spring clipwith patented adjusting device
Pair of steel cords
Length 1,000 mm 60 210 027 >
One pair of steel cords required per mounting frame.
To specify e.g.:L-TOOLS through-wiring with sockets Reel with total length of approx.10 m 60 210 009