Catalogue Modular lighting systems- Lightools
www.zumtobel.com
print switch display
Page / 45
Make a request   
ZUMTOBEL - 811
/ 45
See other catalogues for ZUMTOBEL
Text version of the page

LIGHTTOOLS

L-TOOLS flush mounting frame L-TOOLS blank flush mounting frame L-TOOLS end-plate set, flush mounting

Cat. no. kg Order no.

Mounting frame for section withoutflange • For adjusting and fixing a channelsection within a suspended plaster- board ceiling or similar• Used as sharp edged trim on plaster-board,gypsum ceilings• Snap-in mechanism for fixing channelsection• Frame is inserted into ceiling cut-out(prepared on site) and fastened withscrews• Incl.spacing brackets fitted for exactobservance of width of opening,and for accommodating steel cord sus- pensions for transferring weight to load-bearing ceiling• Material:extruded aluminium section/galvanised sheet steel• Incl.butt-joint connector modules forlinking with next mounting frame

Mounting frame length 1,600 mm,for

Panel thickness 12.5 mm 4.0 60 210 014 Panel thickness 15 mm 4.0 60 210 015 Panel thickness 20 mm 4.0 60 210 016 Panel thickness 25 mm 4.0 60 210 017

Moounting frame length 800 mm,for

Panel thickness 12.5 mm 2.5 60 210 018 Panel thickness 15 mm 2.5 60 210 019 Panel thickness 20 mm 2.5 60 210 020 Panel thickness 25 mm 2.5 60 210 021

Order same no.of mounting frames (1,600 or 800 mm) as channel sections.

Cat. no. kg Order no.

Blank mounting frame for sectionwithout flange (unassembled)

Blank mounting frame length 1,600 mm,for

Panel thickness 12.5 mm 4.0 60 210 022

• For cutting to suit on site (minimumlength 800 mm!) and subsequent assembly to a shortened frame• Design otherwise as in L-TOOLSmounting frame,flush mounting• Incl.distance brackets (to be fittedafter frame has been cut to suit) enc- losed for exact observance of width of opening,and for accommodating steel cord susp.for transferringweight to load-bearing ceiling• Incl.2 end-plate modules,for closureof entire mounting frame length and which also serve as plastering edge trims at front end

Panel thickness 15 mm 4.0 60 210 023 Panel thickness 20 mm 4.0 60 210 024 Panel thickness 25 mm 4.0 60 210 025

Same number and length to be fitted as blank channel sections.After being cut to length on site,both distance brackets have to be fitted.See formula for determining number of channel sections required on page 16.

Cat. no. kg Order no.

End-cap set,flush mounting

End-cap set

• Closure of both ends of a channellength flush with ceiling (for both channel section and mounting frame) • To be fitted in on site and screw-fastened to ends of channel• Also serve as plastering edge trims atfront end• 1 end plate with integrated 7-poleterminal for feed-in•Material:extruded aluminium section/galvanised sheet steel• Colour:titanium

2 off,flush mounting 0.8 60 210 026

Only to be ordered if no blank modules (channel sections and mounting frames) are used.Therefore required if channel length is made up only of standard lengths 1,600/800.

To specify e.g.:L-TOOLS flush mounting frame Panel thickness 12.5 mm 60 210 014

ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
pdf-page pdf ae En 2008-10-42-15