Installation

LIGHTTOOLSINSTALLATION 17

Efficient, precise, clean ...

Ceiling cut-out:Approx. 124 mm wide Length - length of section + 14 mm supporting edges of the plasterboard panels in the ceiling cut-outmust be unobstructed over a width of approx. 20 mm, so that the mounting frame rests cleanly on them to ensure a straight,flush fit. channelsection
Ceiling cut-out:Approx. 121 mm wide Length – length of section + 26 mm Distance between upper edge of suspended and structural ceiling: First measure up and prepare the ceiling cut-out . The exact di-mensions and details depend on the way the section is fitted (“flush-mounted” or “ceiling-bearing”. When flush-mounted, the from twosteel cords and usethem to level it.Place the ceilingpanels at the sidesover the edges of the channel section.METHOD 2: Insertthe

...flush-mounted ... ceiling-bearing

Insert the mounting frame complete with end plate into the cut-out and rest it on theceiling panels. Attach steel cords to brackets, tension slightly and later pull upwards to precise height. Screw-fasten the supportingfins roughly every 10 cm from below through the ceiling panels. Insert further frames, connect the joints and tighten the screws. Fitthe second end plate. Plaster the joints andfinish off the ceiling. Run the channel section into the ceiling cut-out already attachedto the cord and usethe cord to pull itupwards.
at least 180 mm Push the first channel section fitted with an endplate into theceiling cut-out and snap it into the mounting frame. Tighten thebolts of the brackets. Offer upthe next section and connect the joint with two springs, finally insert the second end plate. Click the connected through-wiring directly into the channel section, click itinto place and connect to the feeder. If required, insert plastic trims into the channel section in order to conceal the wiring. Con-nect the lighting inserts to the phase selector plug as required. lighting inserts into the channel section in therequired position. “Empty” channel lengths can be blanked off by using an aluminium cover section. This creates a clean, flush, un-obtrusive look with attractive lines. In order to obtain additionallighting effects, it is possible, if required, to provide the cover plate with light slits or, for example round openings which can be backed by coloured strips and backlit by lighting inserts fitted withT16 lamps. METHOD 1: Sus-pend the
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Marine directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45