| Specific thermal standard 54 = 0,73 W/m2K Conductivity plus 66 = 0,60 W/m2K H 89 = 0,44 W/m2K Water vapour permeability the system is vapour permeable with open joint panel certified permeability value u=86 Water Absorption under full water immersion after one hour less than 0,03 Kg/m2 Panel weight the average weight is 20 Kg/m2 Resistance system under variable from min = 3300 N/m2 to max = 6270 N/m2 wind suction test on base of panel dimensions and type of joint "0" or "15" see ETA evaluation document Impact Resistance comply category I e III ETAG 17 overlap the impact soft test 400 Joule and hard impact test 10 Joule see ETA evaluation document Reaction to fire Euroclass E or old Italian classification class 1 art.8 D.M. 26-06-1984 or old French classification M1 Brief description of panel over-all thickness 54/66/89 mm. made up of 8-9 cladding system PIZ mm. external cement mortar bonded to a 45/57/80 mm. expanded polystyrene insulation layer. Anodised aluminium support rail in standard colours black or silver (on demand painted in RAL colour or same colours of the Panel sizes below schedule of standard panel sizes with possibility a plus or minus 20 mm. sizing increments |