TopWing Unit Heater TLH - TLHK
52Pages

{{requestButtons}}

Catalog excerpts

TopWing Unit Heater TLH - TLHK - 1

Technical documentation TopWing Unit Heater TLH TLHK 1

Open the catalog to page 1
TopWing Unit Heater TLH - TLHK - 3

TopWing Unit heaters The TLH-series unit heaters were developed specifically for convenient heating. Various models are available, catering to the following applications: heating, ventilation or filtration. Each device can be used in conjunction with suitable accessories for recirculated-air, mixed-air or outdoor-air operation and mounted on the wall or ceiling. There are four different sizes for air flow rates up to 9000 m³/h and heating-power ratings up to 164 kW. TLH Cu/Al heat exchanger: The heating elements are large-size registers. The advantage of this arrangement is that discharge...

Open the catalog to page 3
TopWing Unit Heater TLH - TLHK - 4

TopWing Unit heaters The TLHK-series unit heaters were developed specifically for convenient heating or cooling. Shey are suitable for heating or cooling. Each device can be used in conjunction with Each device can be used in conjunction with suitable accessories for recirculated-air or mixed-air and mounted on the wall. Air filtration is also possible with the relevant accessories. There are four different sizes for air flow rates up to 9000 m³/h and heating-power ratings up to 164 kW, or air flow rates up to 4280³/h im Kühlbetrieb und einer cooling-power ratings up to 37,5kW. TLHK Cu/Al...

Open the catalog to page 4
TopWing Unit Heater TLH - TLHK - 11

TopWing Shut-off sets / Fixing accessories Shut-off sets for heat exchanger TLH / TLHK Shut-off set as straight-through version or angled version for heat exchanger flow and return for TLH 25: Type 2/3/4, TLH 40: Type 2/3/4, TLH 63: Type 1, TLH 100: Type 1 and TLHK units are suitable for heating water temperatures up to 110 °C and an operating pressure up to 10 bar. Comprising: • 1“ fitting for connection to flow and return with flat gasket • Automatic air vent valve (quick-action air vent valve) with automatic shut-off valve in the flow • Drain & fill valve with cap and hose connection in...

Open the catalog to page 11
TopWing Unit Heater TLH - TLHK - 12

TopWing Fixing accessories Fixing set for concrete beam, vertical TLH/TLHK 25 40 For fixing the TLH/TLHK to a concrete beam by hooking it into a pre-assembled installation rail. Provide rawl plugs and screws on site. Comprising: Installation rail, 2 mounting rails (zinc-plated sheet steel), screws and nuts. Part No. 65 00 781 65 00 782 Mounting rail Fixing set for steel beam, vertical TLH/TLHK 25 40 b 100-300 100-300 25 40 b 100-300 100-300 Support rails Mounting brackets TLH-appliance For fixing to a steel beam by hooking into a pre-assembled installation rail using clamping claws....

Open the catalog to page 12
TopWing Unit Heater TLH - TLHK - 13

TopWing Fixing accessories Fixing set for tilted steel beam with self-aligning brackets TLH / TLHK For fixing to a steel beam with a flange width “b“ of 100 mm to 300 mm, and a flange thickness “t“ of 6 mm to 21 mm. Comprising: 2 mounting rails (zinc-plated sheet steel), 4 clamping claws, 4 self-aligning brackets, screws and nuts. Mounting rail Clamping claw M8 threaded rods (on site) Fixing panels Self-aligning bracket TLH unit TLH 25 40 Hangers for configurations with horizontal air flow b 100-300 100-300 t Part No. 6-21 65 00 787 6-21 65 00 788 For suspending the TLH/TLHK heater...

Open the catalog to page 13
TopWing Unit Heater TLH - TLHK - 14

TopWing Fixing accessories Hangers for configurations with vertical air flow TLH / TLHK For suspending the TLH heater horizontally from the ceiling, powder-coated, color standard white RAL 9016. Suitable for use in conjunction with threaded rods or perforated strip for configurations with vertical air flow. (Set = 4 pce) Outermost anchorange on rear panel TLH 25 40 63 100 Bracket for intake accessory, loose b 580 710 880 1040 c 620 750 920 1080 dmin 250 250 350 350 Part No. 65 00 038 65 00 038 65 00 038 65 00 038 For wall-mount or ceiling-mount installation of the TLH heater and zur for...

Open the catalog to page 14
TopWing Unit Heater TLH - TLHK - 15

TopWing Discharge Accessories Discharge cone TLH To increase throw if the unit is high above the floor. Powder-coated, color standard white RAL 9016. (See pages 35/36 for throw) TLH 25 40 63 100 Discharge nozzle a 280 370 430 530 b 460 590 760 920 c 200 240 270 320 d 750 790 920 1010 Part No. 65 00 333 65 00 403 65 00 406 65 00 409 For extended throw, suitable as an air curtain at doors. Discharge temperature for air-curtain operation approx. 10-15°C above room temperature. Powder-coated, color standard white RAL 9016. (See pages 35/36 for throw) TLH 25 40 63 100 Four-way discharge a 460...

Open the catalog to page 15
TopWing Unit Heater TLH - TLHK - 16

TopWing Discharge Accessories Induction louver with secondary-air cone TLH For optimizing throw and temperature distribution Description of function The induction louver with secondary-air cone divides the warm air into separate flows and inducts secondary air (room air) directly into the current of warm air downstream from the deflector vanes. The induction of secondary air ensures that the warm air is thoroughly mixed with the room air within a very short distance, and this reduces the discharge temperature of the air. This reduction in temperature prevents the warm air from rising, thus...

Open the catalog to page 16
TopWing Unit Heater TLH - TLHK - 17

TopWing Intake Accessories Mixed-air box For custom air-flow settings. Outdoor-air intake at the rear, recirculated-air intake at the side or from above or below with the mixed-air box turned through 90°. Powdercoated, color standard white RAL 9016. Stepless adjustment between recirculated air only through mixed air to outdoor-air only, adjustment manual or by means of 230V servomotor. (Part No. 22 69 522). In Connection with LM2 ventilation control unit 24V stepless (Part No. 22 69 521). TLH/TLHK 25 40 63 100 Recirculated-air box TLH/TLHK 25 40 63 100 a 500 630 800 1000 b 300 500 500 540 a...

Open the catalog to page 17
TopWing Unit Heater TLH - TLHK - 18

TopWing Intake Accessories Filter box TLH/TLHK 25 40 63 100 a 500 630 800 1000 With filter element as dust trap in outdoor-air and mixed-air modes, filter category G4 for TLH-(K) 63, filter category G3 for TLH-(K) 25, 40, 100. Bracket on request. Powdercoated, color standard white RAL 9016. b 300 300 300 340 c 600 600 600 680 Part No. 65 00 549 65 00 554 65 00 559 65 00 564 Rain cowl with birdproof screen TLH/TLHK 25 40 63 100 a 640 770 940 1140 TLH / TLHK b 500 630 800 1000 Roof penetration c 606 736 906 1106 With birdproof screen (flow-stop louver available on request), for inducting...

Open the catalog to page 18