| | | | | | | | | | | | | | | | | | | | | | | TOSHIBA lia | | | | | | | | | | | | | | | | | | | | | | | | | | Outdoor unit | MMY-MAP0802FT8 8 HP | MMY-MAP1002T8 10 HP | MMY-MAP1202T8 12 HP | | | | Cooling capacity* | kW | 22.4 | 28 | 33.5 | | | | Power input, cooling | kW | 6.07 | 8.54 | 12.9 | | | | EER, cooling | W/W | 3.69 | 3.18 | 2.6 | | | | Energy efficiency class, cooling | | A | B | E | | | | Running current, cooling | A | 9.25 | 13.15 | 19.85 | | | | | kW | 25 | 31.5 | 35.5 | | | | Power input, heating | kW | 6.29 | 8.73 | 9.65 | | | | COP, heating | W/W | 3.97 | 3.61 | 3.68 | | | | Energy efficiency class, heating | | A | A | A | | | | Running current, heating | A | 9.55 | 13.4 | 14.85 | | | | Air flow | m3/h - /s | 9900 - 2750 | 10500 - 2917 | 10500 - 2917 | | | | Sound pressure level - at 1 m | dBA) | 57 | 58 | 59 | | | | Operating range - db | °C | -10 - 43°C | -10 - 43°C | -10 - 43°C | | | | Operating range - wb | °C | -20 - 15.5°C | -20 - 15.5°C | -20 - 15.5°C | | | | Dimensions (H x W x D) | mm | 1800 x 990 x 750 | 1800 x 990 x 750 | 1800 x 990 x 750 | | | | Weight | kg | 263 | 263 | 263 | | | | Compressor type | | Hermetic | Hermetic | Hermetic | | | | Refrigerant charge R410A | kg | 11.5 | 11.5 | 11.5 | | | | Pipework | | | | | | | | Suction line type - diameter | in | Brazed - 7/8 | Brazed - 7/8 | Brazed - 1 - 1/8 | | | | Liquid line type - diameter | in | Flare - 1/2 | Flare - 1/2 | Flare - 1/2 | | | | Discharge line connection type - diameter | in | Brazed - 3/4 | Brazed - 3/4 | Brazed - 3/4 | | | | Maximum equivalent length separation | m | 150 | 150 | 150 | | | | Maximum actual piping separation | m | 125 | 125 | 125 | | | | Maximum pipe length | m | 300 | 300 | 300 | | | | Maximum lift (Indoor unit above/below)*** | m | 30/50 | 30/50 | 30/50 | | | | Power supply | V-ph-Hz | 400-3-50 | 400-3-50 | 400-3-50 | | | | | | | | | | | | | | | | | | | | Based on an indoor air temperature of 27°C db/19°C wb and an outdoor air temperature of 35°C db Based on an indoor air temperature of 20°C db and an outdoor air temperature of 7°C db/6°C wb If the height difference between indoor units exceeds 3 m and if the indoor unit is above, max. lift is reduced to 30 m | | | | | | | | | | Protectionrjor devices. • Discharge and suction temperature sensors • Internal overload relay • Compressor overcurrent relay • Overcurrent sensor • High pressure switch • Low pressure sensors | | | | | | 6 | | | | | | | | | | | | | | | | | | | | | | | | | | |
|