Technical specifications
design heat pump
Outoor unit Indoor unit*
RAS-10GAV-E2 RAS-10GKV-E2
RAS-13GAV-E2 RAS-13GKV-E2
RAS-16GAV-E2 RAS-16GKV-E2
Cooling capacity
kW
CO
2.5
3.5
4.62
Cooling range (min. - max.)
kW
CO
0.9 - 3.0
1.1 - 4.0
1.2 - 5.2
Power input (min - rated - max.)
kW
CO
0.26 - 0.76 - 0.97
0.19 - 1.07 - 1.30
0.25 - 1.62 - 1.90
EER
W/W
CO
3.29
3.27
2.85
Energy efficiency class
CO
A
A
C
Annual energy consumption
kWh
CO
380
535
810
Heater
capacity
kW
HP
3.2
4.2
5.9
Heating range (min.-max.)
kW
HP
0.9 - 4.0
1.1 - 5.8
1.3 - 7.4
Power input (min - rated - max.)
kW
HP
0.20 - 0.84 - 1.12
0.19 - 1.13 - 1.64
0.26 - 1.73 - 2.32
COP
W/W
HP
3.81
3.72
3.41
Energy efficiency class
HP
A
A
B
Indoor unit*
RAS-10GKV-E2
RAS-13GKV-E2
RAS-16GKV-E2
Air flow (h/l)
m
3
/h - l/s
CO
528/342 - 147/95
528/342 - 147/95
762/522 - 212/145
Sound pressure level (h/l)
dB(A)
CO
38/27
39/26
45/34
Sound power level (h/l)
dB(A)
CO
51/40
52/39
58/47
Air flow (h/l)
m
3
/h - l/s
HP
618/408 - 172/114
618/408 - 172/114
780/570 - 217/160
Sound pressure level (h/l)
dB(A)
HP
39/29
39/28
44/34
Sound power level (h/l)
dB(A)
HP
52/42
52/41
57/47
Dimensions (HxWxD)
mm
275 x 790 x 218
275 x 790 x 218
275 x 790 x 218
Weight
kg
10
10
10
Outdoor unit
RAS-10GAV-E2
RAS-13GAV-E2
RAS-16GAV-E2
Air flow
m
3
/h - l/s
2405 - 673
2405 - 673
2405 - 673
Sound pressure level
dB(A)
CO
46
48
51
Sound power level
dB(A)
CO
59
61
64
Operating range
°C
CO
15 - 43°C
15 - 43°C
15 - 43°C
Sound pressure level
dB(A)
HP
47
50
53
Sound power level
dB(A)
HP
60
63
66
Operating range
°C
HP
-10 - 24°C
-10 - 24°C
-10 - 24°C
Dimensions (HxWxD)
mm
530 x 660 x 240
550 x 780 x 270
550 x 780 x 270
Weight
kg
30
36
39
Compressor type
DC Inverter
DC Inverter
DC Inverter
Flare connections
Gas
in
3/8
3/8
1/2
Liquid
in
1/4
1/4
1/4
Maximum pipe length
m
10
15
15
Maximum height difference
m
8
10
10
Pre-charged pipe length
m
10
15
15
Power supply
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
* Also available in Multi-split (Cooling only and Heat pump) - see Matching
rustic table
pages 22-23
heat pump
cooling only
Indoor units Single-split Outdoor units Indoor units Multi-split Outdoor units (2 rooms) (2 rooms)
(3 rooms)
(4 rooms)
10GKV-E 10GAV-E
13GKV-E 13GAV-E M13GKV-E M14GAV-E M18GAV-E
3M26GAV-E 4M27GAV-E
16GKV-E 16GAV-E
M10GKV-E M14GAV-E M18GAV-E 3M26GAV-E 4M27GAV-E
M16GKV-E M18GAV-E
3M26GAV-E 4M27GAV-E
M10GKCV-E M14GACV-E M18GACV-E
3M23GACV-E 4M27GACV-E
M13GKCV-E M14GACV-E M18GACV-E
3M23GACV-E 4M27GACV-E
M16GKCV-E M18GACV-E
3M23GACV-E 4M27GACV-E
154322_Residential_brochure_06.i27 27 14-02-2007 12:30:53