toshiba f
Technical specifications cooling only
Outdoor unit
RAS-10GA-ES2
RAS-13GA-ES2
RAS-18GA-ES2
RAS-24GA-ES2
Indoor unit
RAS-10GKP-ES2
RAS-13GKP-ES2
RAS-18GKP-ES2
RAS-24GKP-ES2
Cooling capacity
kW
CO
2.73
3.75
5.33
6.83
Power input
kW
CO
0.84
1.15
1.91
2.63
EER
W/W
CO
3.25
3.26
2.79
2.60
Energy efficiency class
CO
A
A
C
D*
Annual energy consumption
kWh
CO
420
575
955
1315
Running current
A
3.76
5.15
8.60
12.53
Outdoor unit
RAS-10GA-ES2
RAS-13GA-ES2
RAS-18GA-ES2
RAS-24GA-ES2
Air flow
m3/h - l/s
CO
1740 - 483
2030 - 564
2120 - 589
3380 - 939
Sound pressure level
dB(A)
CO
46
50
51
56
Sound power level
dB(A)
CO
59
63
64
69
Dimensions (H x W x D)
mm
CO
550 x 780 x 290
550 x 780 x 290
550 x 780 x 290
715 x 780 x 290
Weight
kg
CO
30
38
39
63
Technical specifications home heat pump
Outdoor unit Indoor unit
RAS-10GAH-ES2 RAS-10GKHP-ES2
RAS-13GAH-ES2 RAS-13GKHP-ES2
RAS-18GAH-ES2 RAS-18GKHP-ES2
RAS-24GAH-ES2 RAS-24GKHP-ES2
Cooling capacity
kW
CO
2.73
3.78
5.03
6.30
Power input
kW
CO
0.84
1.17
1.88
2.47
EER
W/W
CO
3.25
3.23
2.68
2.55
Energy efficiency class
CO
A
A
D*
E*
Annual energy consumption
kWh
CO
420
585
940
1235
Running current
A
CO
3.76
5.25
8.40
11.45
Heater capacity
kW
HP
2.94
4.23
5.50
6.85
Power input
kW
HP
0.81
1.16
1.72
2.44
COP
W/W
HP
3.63
3.65
3.20
2.81
Energy efficiency class
HP
A
A
C
D
Outdoor unit
RAS-10GAH-ES2
RAS-13GAH-ES2
RAS-18GAH-ES2
RAS-24GAH-ES2
Air flow
m3/h - l/s
2030 - 564
2120 - 589
1830 - 508
3380 - 939
Sound pressure level
dB(A)
CO (HP)
47 (47)
49 (49)
52 (53)
56 (57)
Sound power level
dB(A)
CO (HP)
60 (60)
62 (62)
65 (66)
69 (70)
Dimensions (H x W x D)
mm
550 x 780 x 290
550 x 780 x 290
550 x 780 x 290
715 x 780 x 290
Weight
kg
32
40
50
65
Technical specifications cooling only and heat pump
Indoor unit HP
CO
RAS-10GKHP-ES2 RAS-10GKP-ES2
RAS-13GKHP-ES2 RAS-13GKP-ES2
RAS-18GKHP-ES2 RAS-18GKP-ES2
RAS-24GKHP-ES2 RAS-24GKP-ES2
Air flow (h/l) m3/h - l/s CO Air flow (h/l) m3/h - l/s HP Sound pressure level (h/l) dB(A) Sound power level dB(A) Dimensions (H x W x D) mm Weight kg
540/340 - 150/95 560/400 - 155/110 41/31 54
250 x 740 x 185 8
630/430 - 175/120
650/490 - 180/135 41/31 54
275 x 790 x 218 10
900/625 - 250/174 900/625 - 250/174 44/35 57
298 x 998 x 220 13
900/625 - 250/174 900/625 - 250/174 45/37 58
298 x 998 x 220 13
Outdoor unit HP
CO
RAS-10GAH-ES2
RAS-10GA-ES2
RAS-13GAH-ES2 RAS-18GAH-ES2
RAS-13GA-ES2 RAS-18GA-ES2
RAS-24GAH-ES2
RAS-24GA-ES2
Operating range °C CO Operating range °C HP Flare connections, Gas - Liquid in Maximum pipe length m Maximum height difference m Pre-charged pipe length m Power supply V-ph-Hz
15 - 43°C -10 - 24°C
3/8 -1/4 10 5 10
220/240-1-50
15 - 43°C -10 - 24°C
1/2 - 1/4 15 6
15
220/240-1-50
15 - 43°C -10 - 24°C
1/2 - 1/4 20 8 15
220/240-1-50
15 - 43°C -10 - 24°C
1/2 - 1/4 25 10 15
220/240-1-50
For residential applications, energy efficiency class C or above is recommended.