Theben - 40 / 152 Pages

Stairway-light time switch, electronic (1 TE)Din rail program

Input8240 V AC/DC >
12345678910

0.5֖20 min 60 min 3600 W

ELPA 1 ELPA >
, with multifunction, multi-voltage input,crossover circuit
Function:
Ε Switching duration infinitely adjustable from 0.520 min
֕ High accuracy
Immediately resettable
Օ Crossover circuit for the protection of therelay contact In addition, the crossover circuit protects the luminousmedium, i..e. the life of the luminous medium is
increasedՕ By means of the crossover circuit very high lamp loadsare possible (e.g. 3600 W glow lamp load or a higher
number of energy saving lamps) Multifunction device with 10 selectable functions,adjustable on the device front
- switch-off pre-warning (double flashing twice) Thefunction can be connected and disconnected on the
device front.- 60 min long-term function activatable by long buttonpress. The function can be connected and disconnect-
ed on the device front.- Immediately resettable (stairway light switch) ordisconnectable prematurely (current pulse switch,
current pulse switch with release delay). The function
can be selected on the device front.- Permanent lightՕ Button input with max. 150 mA glow lamp load andelectronic overload protection Connection for 3 or 4 wires (4 wires with connection for floor lighting)Օ Automatic 3-/4-wire recognition
Additional control input galvanically separated for AC/DC 8Յ240 V, e.g. for intercoms Terminal assignment as ELPA 8
Օ Operational safety by very high switching power (e.g.3600 W glow lamp load)ELPA 6 ELPA Technical data:Rated voltage: 220240 V~, +10 %/֖15 % Frequency: 50/60 Hz Device consumption: 6 VA Glow-lamp load: max. 150 mA Setting range: 0.5 to 20 min, infinitely adjustable 3/4 wire setting: automatic Resettable: immediately Duty cycle: 100 % Switch for permanent light: rotary switch Contact type: NO contact Contact: not potential-free Opening width: < 3 mm >

V

Contact material: AgSnO ELPA 1 ELPA 6 >
2 Switching power at 230 V~, cos II ϕ = 1: 16 A Switching power (fluorescent lamps): Fluorescent lamps (KVG) Dual circuit: Protection class when mounted in accordance with
its designated use: Labels: V 3600 VA* 16 AX Incandescent lamp load: 1200 VA (120 F)* Fluorescent lamps (EVG): Housing and insulation material: Admissible ambient temperature: IP 20 3600 W 1000 VA self-extinguishingthermoplasts of high temperature resistance Ֆ25 C... +50 аC Halogen lamp load: Fluorescent lamps (KVG) shunt compensated: Compact fluorescent lamps (KVG): 34 x 7 W, 27 x 11 W, 24 x 15 W, 22 x 23 W Type of protection according to DIN EN 60 529: *With marked lamp loads, a switch-off pre-warning(switch position 2, 4, 7, 9) is not possible! 3600 W 1500 VA* Fluorescent lamps (KVG) uncompensated: 3600 VA* Compact fluorescent lamps (EVG): 3600 VA* Fluorescent lamps (KVG) series compensated: For design, dimensional drawing and terminal cover, see page 39. >
, with multifunction, crossover circuitΕ as ELPA 1, but without multi-voltage input >

ELPA 1/ELPA 6

Functions: Stairway-light timerFunctions: Current pulse switch, pulse switch with release delay >
1 t 5 0,5...20 min OFFON
< 2 s OFFONOFFON 2 + 67 t 0,5...20 min10 s 30 s 0,5...20 min0,5...20 min OFFON 3 + 1h > 2 s> 2 s + 0,5...20 min 1h 10 s30 s OFFON OFFON 89 + 1h < 2 s> 2 s> 2 s> 2 s> 2 s< 2 s< 2 s< 2 s 4 + 1h < 2 s> 2 s> 2 s + 0,5...20 min 10 s30 s10 s30 s1h OFFON 0,5...20 min0,5...20 min 1h1h10 s30 s10 s30 s OFFON + 1h + OFFON 10 PERM Permanent ON OFFON 40 >

Theben
  1. P. 1

  2. P. 35

    Time lag relayDin rail program 0.1 s100 h AC/DC 12֖240 V TM 345 M TM 345 M multifunction relay A1 A2 Input voltage(Supply voltage) B1 ֖...
  3. P. 36

    Flush mounting BEffl H 0.5-20 min Input 8-230 V AC/DC 60 min Stairway-light time switch, electronic ELPA 041 ELPA®,...
  4. P. 37

  5. P. 38

    Staircase time switch, electromechanicDin rail program 17 min Technical data:Rated voltage: 230 V~, ֱ10 % Function: Frequency: 50 Hz Electromecanical...
  6. P. 39

    Staircase time switch, electronicDin rail program Input8240 V AC/DC > 0.5֖20 min ELPA 7 ELPA >Technical data:Rated voltage: Function:Ε...
  7. P. 40

  8. P. 41

    in rail program 0.5-20 min Input 8-240 V AC/DC 60 min 3600 W tairway-light time switch, electronic (1 TE) AC/DC 8...240...
  9. P. 42

    Cut-out warning deviceDin rail program 2060 s 230 V~, ֱ10 % ELPA 4 ELPA >Frequency: 50Ζ60 Hz Function: Device consumption: 1 VA ELPA 4...
  10. P. 43

    Twilight switchDin rail program 2100 Lux For controlling the lighting facilities of streets,external stairways, shop windows, entrances, etc.Automatic...
  11. P. 44

    Twilight switchDin rail program 2200 Lux 2֖2000 Lux 27500 Lux For controlling lighting systems for streets,outside staircases, shop windows, entrances...
  12. P. 45

    Twilight switchDin rail program 2200 Lux 2֖2000 Lux 27500 Lux r r 4 5 L 4 5 LN III 1 2 3 N 1 2 3 LN LN LN LUNA 110 (1 channel) LUNA 112 (1 channel)...
  13. P. 46

  14. P. 47

  15. P. 48

  16. P. 49

  17. P. 50

  18. P. 60

  19. P. 70

  20. P. 80

  21. P. 90

  22. P. 100

Text version

All Theben AG catalogues and technical brochures

  1. Catalogue 2013

    276 Pages

    En
  2. TIME

    56 Pages

    En
  3. THEBEN LIGHT

    112 Pages

    En

Archived catalogues

  1. Product news 2012

    28 Pages

    En
  2. Catalogue 2012

    256 Pages

    En
  3. THEBEN LUXOR

    20 Pages

    En