PITERAK
®
(see diagrams 9 and 10) (see diagrams 7 and 8) . ? Wall top detail: end >
DEALING WITH IRREGULAR POINTS At the top of the work, the Piterak® must be
protected using a waterproof flashing overlapping
the piece.
Top Piterak® are fixed using top stainless steel clips. ? Base detail: start At the base of the work, it is necessary to start
with a metal section, L-shaped, drilled with holes
and fixed to the vertical wall, protecting the
various panels which constitute the cladding and
enabling the drain-off of any water thanks. Bottom Piterak® are fixed by means of standard
stainless steel clips . >
installationclearance10 to 14 mmfixingbracketfixing plugsectionstandardfixing clip installationclearance10 to 14 mmfixing plugfixing bracketsectionstandardfixing clip interaxaial distance 200 mm or 250 mm DIRECT INSTALLATION WALL-CLADDING INSTALLATION start detail start detail Diagram 7 Diagram 8 top fixing clip interaxial distance168 mm or 218 mm installationclearance10 to 14 mmfixingbracketfixing plugsectionstandardfixing clip
top fixingclipmastic installationclearance10 to 14 mmfixing bracketfixing plugsectionstandardfixing clip 91 mm 91 mm DIRECT INSTALLATION WALL-CLADDING INSTALLATION end detail end detail Diagram 9 Diagram 10 Schipol offices, Amsterdam, Netherlands edition No.6 2005 104