(see diagram 13).
ZEPHIR
®
FEATURES
The Zephir® is a single-skin building cladding product whose lightnessmakes it easy and economical to install (with a lightweight sys-
tem resting on horizontal rails). The open joints ensure that the
façade is well ventilated and pressures well balanced. The
Zephir® may also be combined with Phoniceram® (for acoustic
applications).
It is available with three surfaces and in six colours. The elements which constitute the Zephir® wall-cladding system are in conformity with the
Scientific and Technical Centre for Building (CSTB)
Technical Approval n°2/02-971. Perfectly frost
resistant, the building bricks meet French standards NF P
13.304 and EN ISO 539.2 Method C.
They are shock-resistant until Q3 depending the
installation(according to P 08.301 and P 08.302
norms) and resistant under normal wind conditions
in depression in weighted values:
> for an interaxial distance of 600 mm: 1115 Pascals.
> for an interaxial distance of 900 mm: 740 Pascals.
The direct fixing of Zephir® is subjected to
Technical specifications by Terreal, regarding the
product technical characteristics and installation.
The supporting rail is:
Aluminium AMS (Aluminium, Magnesium, Silicium)
alloy corrosion-resistant for outdoor use
DESCRIPTION
This external wall-cladding system, based on
single-wall terracotta building panels is particularly reliable
in its method of fixing. The building tiles have 4 longitudinal
lips on the back (see photos) which enables them
to be hung on a metal supporting rail pegged to
the wall or a frame attached to the main structure.
The double rail supplies half of the upper and the
lower support of the two vertically adjacent tiles (see diagram 1) . (see diagram 3) . (see diagram 2) . ? Wall-cladding installation (insulated cladding)*:The tiles are hung on the rails which are fixed to a
framework that includes the insulation and is fixed
to the wall allowing the realization of walls type
XIII
Diagram 1 >
APPLICATIONS
The tiles are hung on rails fixed directly on concrete
or masonry wall allowing the realization of walls
type III ? Direct installation (non-insulated cladding) Ceramic facing of new or old buildings requiring nomaintenance.
2 types of installation:
ProductZephir* Dimensions (mm)H x L x th ProductCode Quantityof products U. weight(kg) Weightper m >
2 Module(mm) (kg) 300 x 300 x 15300 x 605 x 15 AC01AC02 10,8/m >
2 2 36 3232 305 x 305305 x 610 5,4/m Aluminiumrail 40 x 3000 x 20AC303,5lm/m >
2 1,51,75305 Extra Largerail 53 x 3000 x 20AC403,5lm/m >
2 1,92,21316 >
H = height - L = length - th = thickness Time required: 40min/m 2 (for the main body of the work)Time required for treatment of particular points: 1 h/lm (lintel, supports, opening supports).* Identical values whatever the finish: smooth, sanded, ridgedNota: the 305 gauge is only for the installation with rail in aluminium www.terrealfacade.com * Report of traditionality of the CSTB n°. 2/02-971 >