Catalogue Acoustic façades
www.terreal.com
print switch display
Page / 28
TERREAL - 21651
/ 28
See other catalogues for TERREAL
Text version of the page
(see diagrams 5 and 7). The tiles manufacturers are then embedded and secured into place with a Sikaflex Pro 11 FC type sealant between the lower lips of the tiles and the upper wing of the rail.

PHONICERAM

®

PHONICERAM

? In both cases:

®

(see diagram 7). The rail is directly fixed to the wall with an interaxial distance of 305 mm (average theoretical gauge indicated on the pallet).

dB

? For Phoniceram® dB: ? For Phoniceram®: (see diagrams 4,5 and 6) When the framework is installed (vertical and horizontal adjustments thanks to brackets), the spaces are filled with an acoustic insulation, reference Rockwool 381-652 (thickness: 80 cm, density: 147 kg/m
3 )thickness 80 mm 3 ) or Protisol by Eurocoustic.This insulator can be covered with a black PVC screen (density: 70 gr/ m
2 ). The thickness of the insulator must be equal to the thickness of the space to be filled so that the rail abuts the face of the insulation. The rail is fixed onto the frame with a wood screw (for wooden frames) or a self-tapping screw (for metal frames) with a theoretical interaxial distance of 305 mm (average theoretical gauge indicated on the pallet).
Phonicéram® 30 x 30 Phonicéram® 30 x 60,5 metal frameworkfixing bracket rail insulator Rockwool 381-652(d = 147 kg / m PHONICERAM®: installation principle Diagram 4 5 300 300 5 mm -+1,5 mm metalframeworkbracket ISOLCOverticality adjustment positionned alternalyon either side of the vertical membervertical jointrail maximum length = 3mdimensions in mm section interaxial distance = 900mm(indoors the interaxial distance forfixings may be extended to 1200 mm) Having taken off the broken part, it is necessary to reduce the lower lip of the replacement tile to a thickness of about 4 mm, this way it is ready to be installed: it is then necessary to apply strip of mastic between the lower lip of the replacement tile and the upper wing of the rail.
5 ? Technique of replacing a broken tile
2 mm -+1 mm 361422 80 mastic of typeSikaflexPro 11 FCJ : operating clearance =I : horizontal joint = J 5 mm -1 mm+2 mm MAINTENANCE OF THE WORK PHONICERAM®: PHONICERAM®: In spite of the high intrinsic resistance of thepanels of acoustic façades, in the event of an accident , the pieces of a broken tile will not fall down; the upper part remain suspended, the lower part stuck to the rail. Even thought it is easy to replace independent tiles, it is impossible to remove an entire piece.
vertical section horizontal section Diagram 5 Diagram 6 wall plug accordingworksheet no. 1661rockwool withblack PCV screen dimensions in mmrail J Phonicéram® dB theoretical installation grid 305(recommended exposure indicated on the pallet) PHONICERAM® dB : vertical section Diagram 7 dimensions in mm edition N°6 2005 128
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Marine directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28