(see diagrams 4, 5, 6 and 8). INSTALLATION IN MASONRY COVERING (without the use of rail) Phonbric® can also be built with a traditional
cement mortar batched at 450 kg/m >
DEALING WITH IRREGULAR POINTS Phonbric® is equipped with intermediate fixinglips that facilitate the treatment of particular
points such as lintels, jambs, grid pattern
modules on outlet and arrival sections. The cuts can be made on site without difficulty
with a circular disk saw equipped with a diamond
disk adapted to cutting of ceramic materials.
It is then preferable to mask these cutouts with
sections covering the earthenware.
Particular points such as external angles,
overhangs in the upper section of the work,
starting section or finishing section of an
opening can be carried out using metallic or PVC sections. >
hanger 2 hanger 1 dimensions in mm
hanger 3 hanger 4 rail 4/6head slabprotective flashingmastic of typeSikaflexPro 11 FC hanger 2 hanger 1 dimensions in mm
hanger 3 hanger 4 mastic of typeSikaflex Pro 11 FC solution 1 : interaxial distance for 4/6 rail = 303 mm with whole or cut tilesolution 2 : interaxial distancefor 4/6 rail = 173 mm with whole or cut tile manufacturers J = operating clearance= 2 ± 1 mm solution 1 : interaxial distance for 4/6 rail = 107 mm with tile cut from 139 to 269.4 mmsolution 2 : interaxial distance for4/6 rail = 237.5 with whole or cut tile at a value greater than 269.4 mm H = to be determinatedaccording to useH START DETAIL END DETAIL Diagram 5 Diagram 6 3 of CPA. The lips permit the acoustic covering to be
bonded to the wall using rough mortar.
In the case of significant heights, the use of steel
pins (5 mm diameter) will reinforce the bond of
the tile to the wall (the clip being fixed on the
wall going into the horizontal cavities of the tile).
The approximately 1-cm thick masonry joints can be done in the traditional manner (batched
600 kg/m >
free joint5 mm
overhang 15 cm max.overhang10 cm max.tile / 4/6 rail fixing of the railsupport of Phonbric
4/6 rail / fixing fixing bracketrafterPVC angle building beam
fixing of the 4/6 railsupport of tile (see diagram 9). >
3 of CPA). For the processing of thejoints, it is advised to use a mortar of pointing
which limits the risks of efflorescence and stains
on building site. ? Miscellaneous accessories (not supplied byTerreal)> Metallic or PVC sections for the construction ofoverhangs and other various finishes..> Miscellaneous hardware, wall plugs
> Thermal insulation, mastic
> Fixing brackets
> Wooden and metallic frames >
INTERNAL ANGLE EXTERNAL ANGLE Diagram 7 Diagram 8 For further details on installation, see Boreal® >
J
J ≤ ) free joint from 8 to 20 mm
connecting rods(from 3 to 4 /m FRAME AGAINST A SURFACE: vertical section Diagram 9 www.terrealfacade.com 133