video corpo

Hygiene Air Handling Units TANGRA AHU HYG
7Pages

{{requestButtons}}

Catalog excerpts

Hygiene Air Handling Units TANGRA AHU HYG - 2

TUV Rheinland- Bulgaria EOOD Horowith cortiflos that the company Manufactures Ilia product TANGRA AHU-HYG In conformity with following documents: The air quality could be of significant importance for The pure environment and the proper microclimate are a prevention against illnesses, alergies and physiological problems. Many specific activities have very rigid requirements regarding the HVAC systems: - Emergency rooms - High dependency rooms - Food industry - Beverage industry - Clean room - Pharmaceutical industry - Optical industry - Electronic industry TANGRA company has rich experience...

Open the catalog to page 2
Hygiene Air Handling Units TANGRA AHU HYG - 3

PRODUCT RANGE TANGRA air handling units are made in a modular approach allowing their easy assembly, installation and The product range covers six dimension types from 2 000 Filter section final filter Technical characteristics according to the standard - Casing Deflection - Class D1 - Thermal Transmittance - Class T2/T3 - Casing Leakage - Class L3 (M) - Filter Leakage - Class F8 (M) Hygiene requirements in accordance with -All internal surfaces are perfectly flat - Bottom pans with drainage made of stainless steel -All of the sections are provided with doors or removable pans for easy...

Open the catalog to page 3
Hygiene Air Handling Units TANGRA AHU HYG - 4

Construction is made of special aluminum profiles and aluminum jointing corners. The panels are "sandwich" type consisting of an outer and inner cover with integrated thermal and sound insulation. The covers can be made of galvanized sheet metals with powder coating or of stainless steel. Panel thickness are 40 and 60 mm. Hygiene air handling units TANGRA meet class T3 and T2 thermal transmittance MULTIPLE LEAF DAMPER The relief dampers are with manual or fast acting automatic actuator directly connected to the temperature sensor, providing protection from freezing of the water...

Open the catalog to page 4
Hygiene Air Handling Units TANGRA AHU HYG - 5

COOLING SECTION HEATING SECTION Water cooling section - heat exchanger "water-air" made by copper tubes with aluminum lamellas (spacing between lamellas 2,5 mm). A condensation tray of stainless steel is built in Specific coverage over the lamellas is also DROP SEPARATOR Designed to capture and brings out condensation drops from the cooling section. Made of stainless profiles and mounted with cooling section on the same condensation tray. Water heat exchanger built of copper tubes with aluminum lamellas (minimal spacing between Section can be made of two or four rows and is equipped with a...

Open the catalog to page 5
Hygiene Air Handling Units TANGRA AHU HYG - 6

Air-conditioning and ventilation installations are rarely used to the maximum of their capacity. Optimization of energy costs can be achieved by changing the volume of treated air according to the needs of buildings each moment. This can be realized through the use of frequency inverter and programmable controllers. Frequency Inverter Frequency inverter enables smooth speed control of rpm of three-phase motors. This gives the possibility to reduce operating costs by 25%. Protection class of the frequency inverter can be IP20 or IP66, and the control power of motors varies between 0.37 and...

Open the catalog to page 6
Hygiene Air Handling Units TANGRA AHU HYG - 7

Sofia, 174, Europe boulevard Varna, West Industrial Zone INCOVES Burgas, 6, Transportna Street

Open the catalog to page 7

All TANGRA catalogs and technical brochures

  1. GHP Solutions

    92 Pages

  2. TANGRA PLG

    7 Pages