
VX,VR – Heat recovery units www.systemair.com Good ventilation for private houses, daycare centres, smaller offices and commercial buildings
Open the catalog to page 1Ventilation has a main task. It must take away all pollution produced in a building and take away the dirty air and replace it with clean air. The demand we make upon the ventilation is that it must work in the whole dwelling irrespective of wind and weather, without using more energy than necessary.Ventilation must be economical with energy I n recent years research shows that I we have less strength and perform poorer when we breath bad indoor air. We spent in average 70% - in cold- - of our time indoors. It goes with- out saying that the I 5 000 liters of indoor air we breathe throughout the...
Open the catalog to page 2thoroughly rested ^Quick selection - Residential units Heated space Cold space Name Residential Heat Efficiency Wall Floor Above Cooker hood
Open the catalog to page 3• Rotating heat exchanger • Reversible - left or right hand version • Automatic change normal/summer operation • No need for condensate drain TheVR 300TK/B is a compact unit marily developed for wall mounted installation but can be installed hori- zontally e.g. in a false ceiling. The unit is double skinned, fully insulated, equipped with centrifugal fans for supply/extract air, rotating heat exchanger, filters and thermostat operatedre-heater battery. VR 300TK/B is quipped with large inspection hatches on both sides and is by that means reversible for opti- mal and simple duct connections.The...
Open the catalog to page 4Thermal efficiency With air ratio 1:1 and air humidity 50% The sound data dB(A) in the diagrams indicate the sound power level LwA which should not be confused with the sound pressure level, LpA.
Open the catalog to page 5Rotating heat exchanger Automatic change normal/summer Flexible installation without condensate drain Suitable with cooker hood The unit is suitable for ventilation painted white and designed for installation on the wall or ceiling.VR skinned, fully insulated and with complete control functions, centrifu- gal fans for supply and extract air, rotating heat exchanger, reheater battery and filter. Extract from the cooker hood is led directly to the extract fan, bypassing the exchanger block. Antivibration ceiling mounting brackets and inspection doors on both sides makes the unit easy to place and...
Open the catalog to page 6Thermal efficiency With air ratio 1:1 and air humidity 30% % [m3/h] The sound data dB(A) in the diagrams indicate the sound power level Lw^ which should not be confused with the sound pressure level, LpA. VR Rotating heat exchanger ATF Operating thermostat sensor OF Overheating thermostat sensor BT Emergency thermostat sensor BP By-pass (for cooker hood) EAT Temperature sensor, extract air
Open the catalog to page 7Rotating heat exchanger Automatic change normal/summer Flexible installation without condensate drain homes, offices and smaller areas in commercial buildings.The units are painted white and designed for installation on the wall in laundry room, store room, closet etc. The units are designed with dou- ble skin sheet metal casing with inter- mediate insulation.The centrifugal extract and supply fans are equipped with maintenance free external rotor motors. Control system, rotation heat exchanger, thermostat operated re-heater battery and filters are stan- function that allows the unit to be connected...
Open the catalog to page 8grams indicate the sound power level LwA which should not be confused with the sound pressure Thermal efficiency With air ratio 1:1 and air humidity 30% grams indicate the sound power level LW£ which should not be con- fused with the sound pressure Thermal efficiency With air ratio 1:1 and air humidity 30%
Open the catalog to page 9Rotating heat exchanger Automatic change normal/summer Flexible installation without condensation drain 50 mm of insulation. Can be installed in cold places Complete units for ventilation of homes, offices and smaller com- mercial buildings.The units are design- ed with double skin sheet metal cas- ing with intermediate insulation.The centrifugal extract and supply fans are equipped with maintenance free external rotor motors. Control sys- tem, rotation heat exchanger, thermo- stat operated re-heater battery and automatically alternate between nor- mal operation with heat recovery and summer...
Open the catalog to page 10grams indicate the sound power level LwA which should not be confused with the sound pressure Thermal efficiency With air ratio 1:1 and air humidity 30% grams indicate the sound power level LwA which should not be confused with the sound pressure Thermal efficiency With air ratio 1:1 and air humidity 30%
Open the catalog to page 11Integrated or remote control panel Built-in filter guard Cross flow heat exchanger homes, offices and smaller areas in commercial buildings.The units are painted white and designed for installation on the wall in laundry room, store room, closet etc. The units are designed with dou- ble skin sheet metal casing with inter- mediate insulation.The centrifugal extract and supply fans are equipped with maintenance free external rotor motors. Control system, cross flow heat exchanger, thermostat operated pre-and re-heater battery and filters are standard.The pre-heater defrosts the exchanger to ensure...
Open the catalog to page 12grams indicate the sound power level LW£ which should not be con- fused with the sound pressure Thermal efficiency With air ratio 1:1 and air humidity 30% grams indicate the sound power level LwA which should not be con- fused with the sound pressure Thermal efficiency With air ratio 1:1 and air humidity 30%
Open the catalog to page 13Flexible installation and easy User friendly control panels Automatic defrost function Built-in filter guard Inspection panel on both sides Cross flow heat exchanger Complete units for ventilation of homes, offices and smaller commercial buildings.The units are designed with double skin sheet metal casing with intermediate insulation. The centrifugal extract and supply fans are equipped with maintenance free external rotor motors. Control system, cross flow heat exchanger, thermostat operated pre- and re-heater battery and filters are standard.The pre-heater defrosts the exchanger to ensure proper...
Open the catalog to page 1424 Pages
3 Pages
5 Pages
9 Pages
10 Pages
4 Pages
28 Pages
584 Pages
12 Pages
8 Pages
8 Pages
268 Pages
8 Pages
174 Pages
90 Pages
24 Pages
464 Pages
68 Pages
403 Pages
20 Pages
104 Pages
64 Pages
138 Pages
80 Pages
6 Pages
80 Pages
6 Pages
6 Pages
82 Pages
16 Pages
76 Pages
20 Pages
16 Pages
12 Pages
4 Pages
12 Pages
4 Pages
12 Pages
4 Pages
60 Pages
8 Pages
6 Pages
40 Pages
6 Pages