Two cooling units keep you cool
Cooling system wi
th dir
ect expansion
Swegon cooidx
The CoolDX is a complete cooling system for comfort cooling, for
The CoolDX operates on the principle of direct expansion, i.e. the refrigerant transfers cooling energy directly via pipework with coils. The cooling unit operates in 3 building stages - a special function that also makes stepless regulation possible. The building heat exchanger in the GOLD is then used in parallel with the cooling compressors.
All equipment is housed inside one and the same unit and can be docked to the GOLD via ordinary building duct connections.
Besides the above, only an electrical power supply and a communica­tion cable (with quick connector) are needed between the CoolDX and the GOLD.
The GOLD has ready-to-use cooling functions for controlling and
regulating the CoolDX. This also includes communication via web or traditional supervisory systems.
This means that no extra equipment whatsoever is needs to be planned, procured or installed!
The CoolDX is available for the size 08 - 60 GOLD units. A floor stand is available as an accessory for size 08 units. Base building beams are standard for the size 14 - 60 units.
Swegon cooler
ig system that operates indirect!]
The COOLER is a complete system for comfort cooling, for GOLD air handling units.
The COOLER has an indirect cooling system, i.e. the refrigerant transfers cooling energy via a heat exchanger to a water system with coils.
The great advantage with this system is that the cooling temperature will always be even, since the water reacts comparatively slowly to cooling energy and to heat.
The COOLER is available in six sizes with cooling efficiency from 14 to 60 kW. On the basis of their cooling capacity, the six sizes are specially suited for use with the GOLD 08 — 60 air handling system.
The condenser coil of size 14 and 18 COOLER units is built into the cooling unit. The whole cooling unit is designed for connection to the exhaust air duct connection of the air handling unit. Cooling coil must be installed in the supply air duct and be connected to the cooling unit via pipework installed at the building site. A stand, base beams and connection frames are available as accessories.
The size 24, 34, 48 and 60 COOLER cooling units are detached units mounted on base beams. The cooling coil must be installed in the supply air duct and the cooling agent cooler is installed in the exhaust air duct. Cooling coil and cooling agent cooler must be connected via pipework to the cooling unit at the building site.
The COOLER has a built-in control and regulation system which can be operated from the GOLD.
5
Due to its policy of continuous product development and improvement, Swegon reserves the right to alter specifications without notice.
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
pdf-page pdf ae En 2008-12-49-05