Sunnex CLM-Series – 1x24/1x36/2x18/2x24/2x36W Fluorescent tube
® ››› TECHNICAL DATA Wattage - ComparisonFluorescent tube – Dulux L (left) and Dulux F (right) Main voltage: 230V/50Hz >
125 W180 W
200 W
250 W
360 W1x24 W1x36 W
2x18 W
2x24 W
2x36 W Nominal effect: 1x24, 1x36, 2x18, 2x24 or 2x36W Class: I IP-Class: IP20 Equipped with: 230V HF-ballast or conventional ballastCompact fluorescent tube; 1x24, 1x36, 2x18,2x24 or 2x36WTube model: L – 1xY = 2 G10, F – 2xY = 2 G11 ››› MOUNTING INSTRUCTIONS Mount the lamp on a horizontal surface with the four attached M5-screws.Hole pattern, see dimensional drawing on page 21.Mounting accessory available for the Sunnex CLM-Series; C-clamp.Plug in the cordset to 230V main socket. On/off function is handled withswitch in lamphead. ››› NOTE Use only Sunnex original parts to secure the function and performance ofSunnex lighting-series.If the screen is broken, it must be replaced by a new screen. If the cord-set is damaged, it must be replaced with a new cordset and it should be done
by the manufacturer or a person with sufficient electrical knowledge.Contact your local dealer if you are unsure how to handle replacementson Sunnex CLM-series. ››› CHANGE THE FLUORESCENT TUBE Disconnect cordset from main socket. Unscrew the gable part of lamphead,pull out the broken tube and replace with a new tube. Screw the gable partback in place. info@sunnex.se www.sunnex.com 20 >