1. Catalogs
  2. Soitec
  3. Soitec CX-S530-II CPV System 29.4 kWp
video corpo

Soitec CX-S530-II CPV System 29.4 kWp

Soitec CX-S530-II CPV System 29.4 kWp
1 / 16 PagesView full catalog

Soitec CX-S530-II CPV System 29.4 kWp

Product catalog summary
Overview
The Soitec CX-S530-II CPV System is a high-efficiency solar power solution using ConcentrixTM technology, designed for both US and international markets with region-specific components.
System Components
  • CPV Modules: Includes 12 CX-M500 modules with solar cell assemblies and Fresnel lenses, available in two variants based on DC connector types and certifications.
  • Tracker: The CX-T030-II tracker supports and moves modules to follow the sun, with US and Rest-of-World variants.
  • Tracker Control Unit: The CX-TC2 unit manages tracker movements and system monitoring, tailored for regional requirements.
  • Air Drying Unit: Maintains low humidity within modules, available in integrated (CX-AD1) and centralized (CX-AD2) designs.
Technical Specifications
  • CPV System: Nominal DC power output of 29.4 kWp, ground coverage ratio of 16%, and maximum height of 8.0 meters.
  • CPV Module: Each module outputs 2450 Wp under standard conditions, with a concentration ratio of ~500 and passive cooling.
  • Tracker: Two-axis tracking with 5° to 90° elevation and 300° azimuth, supporting high wind speeds.
  • Tracker Control Unit: Offers multiple tracking modes and robust communication interfaces, with high protection class ratings.
Certifications and Compliance
The system and components are certified under international standards like CE, IEC, and UL, ensuring safety and performance compliance.
Conclusion
The Soitec CX-S530-II CPV System is a versatile and efficient solar power solution, suitable for diverse locations and compliant with international standards.
CX-AD1 Air Drying Unit Technical Data
  • Type: CX-AD1
  • System Architecture: One per CX-S530-II or shared between up to 3 units
  • Integration: Fully integrated, single unit design
  • Certifications: CE
  • Communication Interface: RS232
  • Number of Air Outlets: 4
  • Protection Class: IP 03
  • Electrical Connection: 1-phase, 208 V or 230 V ± 10%; 50 Hz or 60 Hz
  • Power Consumption: Idle: 9 VA / 11 VA (3 W / 5 W); Drying: 140 VA / 190 VA (100 W / 140 W); Regeneration: 380 VA / 560 VA (250 W / 380 W)
  • Dimensions: 289 mm x 545 mm x 974 mm
  • Weight: 15 kg
  • Noise Emission: Idle - Noiseless; Drying and Regeneration - 75 dB(A)
  • Operating Ambient Temperature: Idle and Regeneration: -20°C to +50°C; Drying: -20°C to +30°C
CX-AD2 Air Drying Unit Technical Data
  • Type: CX-AD2
  • System Architecture: Shared between up to 56 units
  • Integration: Centralized, with compressor and pneumatic box
  • Certifications: CE (UL certifications in progress)
  • Communication Interface: Ethernet/Modbus via TCP/IP
  • Number of Air Outlets: 14, each supporting up to 4 units
  • Protection Class: IP 55, requires operation under shelter
  • Electrical Connection: 1-phase, 208 V or 230 V ± 10%; 50 Hz or 60 Hz
  • Power Consumption: Idle: 120 VA (95 W); Drying: 5500 VA (4100 W)
  • Dimensions: 1.58 m x 0.84 m x 1.30 m
  • Weight: 230 kg
  • Noise Emission: Idle - Noiseless; Drying - 71 dB(A) at 1 m, 43 dB(A) at 25 m
  • Operating Ambient Temperature: Idle: -20°C to +55°C; Drying: -20°C to +30°C
Contact Information
  • Europe: Soitec Solar, Paris, France and Freiburg, Germany
  • America: Soitec Solar Inc., San Diego, USA
  • Africa: Soitec Solar, Cape Town, South Africa
See more

Catalog excerpts

Soitec CX-S530-II CPV System 29.4 kWp-1

Technical Data Sheet Concentrix™ Technology

 Open the catalog to page 1
Soitec CX-S530-II CPV System 29.4 kWp-2

Soitec Solar GmbH Version number: © Exclusive property of Soitec. However, v52 this document can be freely read, dissemi- Date: nated, reproduced, translated or quoted in 2014-01-29 whole or in part, by any means and on any medium as long as it is not altered (and anguage. provided that author rights be respected). English - United States (original ver- sion) Concentrix™ is a trademark of Soitec Page 1 CO-Public CX-S530-II_29.4kWp_Technical_Data_Sheet_v52_EN_2014-01-29 |© Soitec

 Open the catalog to page 2
Soitec CX-S530-II CPV System 29.4 kWp-3

Document Version History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 CX-M500 CPV Module Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CX-T030-II Tracker Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 3
Soitec CX-S530-II CPV System 29.4 kWp-4

1.1 Document Version History All units of measurement in this publication are originally metric units. Imperial units are derived from these metric units and are rounded. The "." is used as a decimal point. Technical data is subject to change. Images might differ from actual design. Abbreviation Meaning CE European Commission - Declaration of Conformity CEC California Energy Commission CSOC Concentrator Standard Operating Conditions: 900 W/m2 DNI, 20 °C ambient temperature, AM 1.5D spectrum, 2 m/s wind CSTC Concentrator Standard Test Conditions: 1000 W/m2 DNI, 25°C cell temperature, AM1.5D spectrum....

 Open the catalog to page 4
Soitec CX-S530-II CPV System 29.4 kWp-5

Tracker Ctrl Unit Fig. 2-1 Main components of the CPV System The CPV System consists of the main components: o Tracker Control Unit A specific cabling and tubing set completes the CPV System. Soitec's system integration process ensures that the components fully work together and the CPV System operates safely and reaches its full performance. The CPV Sys- tem can only be operated with the components described in this document. The CX-S530-II CPV System comes in different variants. For example there are US- and Rest-of-World variants of the Tracker Control Unit or integrated or centralized variants...

 Open the catalog to page 5
Soitec CX-S530-II CPV System 29.4 kWp-6

One CPV System includes 12 CPV Modules. A CPV Module consists of solar cell assemblies (SCAs) on the glass receiver plate, and Fresnel lenses on the top lens plate, surrounded by a metal frame. Within one CPV System, DC cables are used to interconnect the CPV Modules. The CPV Module is hollow inside and has an air tube connection point at one end and a membrane permeable to air at the other. A profile rail exists on each side and also in the middle underneath the CPV Module. The profile rail is used for the attachment of the module brackets. CPV Modules generate and output DC power during the...

 Open the catalog to page 6
Soitec CX-S530-II CPV System 29.4 kWp-7

Description Function The Tracker is a mechanical steel structure consisting of a mast, a drive with azimuth and elevation motors, ribs, stringers, and brackets to secure the CPV Modules. The Tracker performs the following functions: Supports the CPV Modules. Moves to follow the sun during the day. The CX-T030_II Tracker exists in two different variants. Both share the same design. CX-T030-II_US with minor US-specific adaptations of the design addresses the requirements of CPV power plants built in the US. CX-T030-II_RoW serves power plant installations outside the US. With both Tracker variants,...

 Open the catalog to page 7
Soitec CX-S530-II CPV System 29.4 kWp-8

CX-TC2 Tracker Control Unit Description The Tracker Control Unit controls the Tracker movements to enable the CPV System to follow the sun throughout the day. It is also used to monitor and control the CPV System remotely. The Tracker Control Unit is controlled via the SCADA system from any location within or outside the CPV Power Plant, using communication interfaces. The Tracker Control Unit performs the following functions: Operates the Tracker movement. Directs the AC power supply to the motors and other components of the CPV Measures the DC power output of the CPV System. Communicates with...

 Open the catalog to page 8
Soitec CX-S530-II CPV System 29.4 kWp-9

CX-AD1 and CX-AD2 Air Drying Unit Description The Air Drying Unit primarily consists of a blower and drier to provide dried air to CPV Modules. A set of tubing goes from the Air Drying Unit to each of the CPV Modules. The Air Drying Unit blows dry air into the CPV Modules to ensure a low relative humidity of air inside the CPV Modules. There are two different Air Drying Units for the CPV System CX-S530-II. CX-AD1 reflects an integrated design approach where the Air Drying Unit is installed within the CPV System. It is possible to use one CX-AD1 in one CPV System. Alternatively one CX-AD1 can...

 Open the catalog to page 9
Soitec CX-S530-II CPV System 29.4 kWp-10

3 CX-S530-II CPV System Technical Data CX-S530-II CPV System Technical Data Number / type of CPV Modules Certifications, compliance, listings Aperture area Module area Array area Ground coverage ratio (at horizontal po- 16% with 27 m x 25 m / 89 ft x 82 ft spacing of CPV Systems. sition) (Spacing may differ for particular power plant projects) Maximum height (at steep; horizontal position) Data valid under nominal conditions: DNI=1000 W/m2, AM1.5D, Tcell=25°C DC power at MPP (PMPP) 29.4 kWp ± 10% (1) (sum of CPV Modules power) Data valid under operating conditions: DNI=900 W/m2, AM1.5D, Tamb=20°C,...

 Open the catalog to page 10
Soitec CX-S530-II CPV System 29.4 kWp-11

4 CX-M500 CPV Module Technical Data CX-M500 CPV Module Technical Data Concentrator type Point focusing silicone on glass Fresnel lenses Concentration ratio Certifications, compliances, listings Solar Cell quantity and type 2400 Triple junction cells per CPV Module Solar Cell cooling system Passive cooling with metal heat sink Solar Cell max. temperature 55 K above ambient temperature Operating ambient temperature Temp. coefficient (PMMP) Temperature coefficient (VOC) Temperature coefficient (ISC) Temperature coefficient graph (Graph does not include tolerances) Data valid under CSTC acc. to IEC...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.