Technical Data
Technical FeaturesWork by Others Technical Features Work by Others
Standard Option FeaturesDescription The works below are not included in the elevator installation work and should be carried out by buildingcontractors in accordance with our drawings, relevant international or local codes and regulations. >
Attendant OperationIndependent OperationBack-up operationSafe Drive OperationSafe Drive OperationCar Call CancellationAutomatic Turn-Off of Car Light & FanAutomatic BypassOverload Holding Stop (110% of rated load)Detection of Jammed Hall ButtonCar Door Safety EdgeMicro LevellingN-Plex OperationNon-Stop OperationParking OperationVIP OperationEmergency PowerOperationFire return operationFiremen OperationAnti-nuisance OperationDoor NudgingVoice SynthesizerDoor Photo Sensor The operating mode of an elevator can be changed from the normal automatic operation tothe attendant service by an attendant switch.Key switch in the car operating panel will cancel any existing car calls and hold the door openat the landing position. During independent operation, the car will respond only to car calls. When the electrical transmission device between the hall call and control panel begins tooperate in an abnormal condition and it lasts for some time, the elevator control device isconverted to back-up operation automatically. Then, the elevator moves in sequence up and
down repeatedly from top to bottom floor to service every other floor which is in normalcondition.When a car stops between floors due to mechanical malfunction, it will descend to the nearest
floor at a low speed and hold the doors open after checking all safety measures.Allows cancellation of an incorrectly registered car call. For example, if you press the buttonfor the wrong floor, you can cancel by pressing the same floor button again.
Car illumination and fan are turned off automatically in case there is no hall call or car call; this
saves energy.A fully-loaded car ( More than 80% of rated load) bypasses hall calls in order to maintainmaximum operational efficiency.
When the number of passengers exceeds the normal capacity, a buzzer sounds and theelevator remains stopped at that floor. When the excessive number of passengers disembark,the buzzer stops, the elevator doors close, and operation continues.
If a hall button is jammed mechanically, the hall call will be automatically bypassed after beingserved once, until the program is resolved.Extending the full height of the car door, this device causes the doors to return to the fully
open position should the door encounter a person or obstacle while closing.
An automatic two way leveling device is provided to maintain the elevator car level with thelanding, regardless of elevator load or direction of travel.It can control up to 4 sets of elevators to optimize allocation of hall calls.
Specific floors which are memorized in control panel can be set to disable using switch on caroperating panel or in security room.The elevator can be automatically parked at the predetermined floor with its doors closed, and
the lights and ventilation will be turned off as well.The specified elevator is controlled by the special call buttons provided only for VIP elevatorIf normal building power supply fails and the building provides emergency power to the
controller(s), one elevator at a time will proceed to the lowest landing where it will stop with
doors open and with all of its power and operating circuits in an inoperative standbycondition.In case of fire, a fireman can use the elevator which is stopped at the specified floor in
order to support firemen for fire-fighting.In case of fire, a firemen can use the elevator which is stopped at the specified floor in order tosupport firemen for fire-fighting.
In case of substantial difference between the number of calls registered on the car operatingpanel and actual load in the elevator, the elevator prevents unnecessary operation bycancelling all registered calls when it arrives at the nearest floor.
When the doors remain open for more than the fixed door open time, this feature closes the
doors at a reduced closing speed with the buzzer sounding.This system provides riding passengers with audio information about car operation such asdirection of travel, landing floor, etc.
The doors reverse to fully open position if the light ray unit detects an obstacle when the doors
are closing. Hoistway A properly framed and enclosed hoistway, including any ventilation as required by the governing code orauthority. A dry pit constructed to the
elevator manufacturer's specifications to reinforce or sustain any vertical forces
on the guide rails and impacted loads from the car and counterweight buffers. A metal sill angle or concrete haunch across the full width of the hoistway at each elevator landing. Provision of steel bars to fix jamb around the entrance of each floor. All cutting, including cutouts to accommodate hall singal fixtures, patching, painting of walls, floors, or
partitions, together with finish painting of
entrance doors and frames, if required. 14 Provision of entrance or ladder for pit access 15 Supply and installation of fascia plate. Installation of emergency exits and electric wiring in blind sections of hoistway where required. The tolerance of perpendicular line over the whole hoistway height must not exceed 30mm. A waterproof outlet and light fixture in the elevator pit area with the light switch being located adjacent to
the access door or ladder. Suitable light fixture and convenience outlet in the pit with a light switch adjacent to the access door or
ladder.The receptacles shall have protection for ground fault circuit interrupter. Provision of wiring between controller and building management system. A construction hoisting beam or hook, if required, with the correct location and size as determinedby the elevator contractor for each hoistway. Noise insulation should be installed between machine room and adjacent residential area. >
Miscellaneous Wiring and piping between monitoring system. Hoistway shall be free of dust or harmful gas. All electric power for lighting, tools, welding, etc during installation. All single phase receptacles installed in pit, and machinery spaces shall have ground fault circuit
interrupter protection. Fire detector for fire emergency operation. A secured area for storage of elevator equipment and materials during installation. The Real Comfort : SOLON >
TM COMFORT >