I Technical Data
A Electrical Modern design Guide
Dil (Speed : 60,90 & 105 m/min) [TW
Speed (m/min)
Capacity
Motor Capa. (kW)
MCCB Capacity of Building (A)
Power Supply Capacity(kVA)
Lead - in Wire Size(mnf)
Earth Wire Size(mnf)
Heat Output (kcal / H)
Starting Power (kVA / set)
n Load Person ,
(kg)
Simplex Duplex
Simplex Duplex
Simplex Duplex
60
6
450
5.5
50 30
4.2
8.4
^^^^
14 5.5
5.5 3.5
675
13.1
8
550
5.5
50 30
5.1
10.2
8 5.5
14 5.5
5.5 3.5
825
16
9
600
7.5
50 30
5.5
11
8 5.5
14 5.5
5.5
900
17.5
10
680
7.5
75 50
150^100
6.3
12.6
14 5.5
22 8
5.5
1020
19.9
11
750
75 50
150^100
6.9
13.8
14 5.5
22 8
5.5
1125
21.8
13
900
75 50
150^100
8.3
16.6
22 5.5
38 14
8 5.5
1350
26.2
15
1000
150^100
9.2
18.4
22 5.5
38 14
8 5.5
1500
29.1
17
1150
150^100
10
20
22 5.5
38 14
8 5.5
1725
23
20
1350
125^100
8.9
17.8
22 5.5
38 14
8 5.5
2025
28.1
24
1600
100 50
200^100
10.5
21
22 8
8 5.5
2400
33.3
90
8
550
9.5
75 50
6.6
13.2
14 5.5
22 8
5.5
1238
20.7
9
600
9.5
7.1
14.2
14 5.5
22 8
5.5
1350
22.6
10
680
9.5
8.1
16.2
14 5.5
38 14
5.5
1530
25.6
11
750
9.5
75 50
150^100
8.9
17.8
5.5
1688
28.2
13
900
13
150^100
10.7
21.4
38 14
2025
33.8
15
1000
13
150^100
11.9
23.8
22 5.5
38 14
14 5.5
2250
37.6
17
1150
13
200^100
11.3
22.6
22 8
14 5.5
2588
35.9
20
1350
15
100 50
200^100
12.8
25.6
38 14
14 5.5
3040
40.7
24
1600
15
125 75
250 125
15.2
30.4
38 14
14 5.5
3600
48.2
105
8
550
11
7.6
15.2
14 5.5
38 14
5.5
1445
24.1
9
600
11
75 50
8.3
16.6
14 5.5
38 14
5.5
1575
26.3
10
680
11
75 50
9.4
18.8
14 5.5
38 14
5.5
1785
29.8
11
750
11
75 50
150^100
10.4
20.8
14 5.5
38 14
5.5
1970
32.8
13
900
15
150^100
12.5
25
22 8
14 5.5
2365
39.4
15
1000
15
150^100
13.8
27.6
22 8
14 5.5
2625
43.8
17
1150
15
125 60
250 125
13.2
26.4
38 14
14 5.5
3019
41.8
20
1350
18
125 75
250 125
15
30
38 14
14 5.5
3544
47.4
24
1600
18
150 75
30^^--125
17.7
35.4
60 22
jo^-^f
4200
56.2
Note. Please contact us if the distance of lead - in wire exceeds 50m.
Heat Output of Machine Room
kcal / H = FXLXS (H : Hour / F : Factor = 1/40 / L : Rated Load(kg) / S : Rated Speed (m/min) / *cal = 4.2 Joule)
Di2 (Speed : 120, 150 m/min), Geared
200V
400V
Capacity
Motor
Person
Load (kg)
Capa.
(kW)
15
1000
18
17
1150
20
20
1350
22
24
1600
24
15
1000
22
17
1150
24
20
1350
27
24
1600
30
Power Supply Capacity(kVA)
Lead-in Wire
Size(mnf)
Earth Wire
Size(rf)
Heat Output (kcal/H)
Starting Power (kVA/set)
14
3000
35
14
3450
39
14
4050
43
14
4800
48
14
3750
46
14
4313
51
22
5063
57
22
6000
64
MCCB Capacity of Building(A)
Speed (m/min)
Simplex
"To
Duplex
18°^J00|
Triplex
24^135
Simplex Duplex Triplex Fourplex
15 30 41 46
Simplex
j§^^4
Duplex
100
Fourplex
27^155
Triplex
Fourplex
38
2II150
30.1 200
17
34
46
51
50-
60
115
160
185
14
30
38
50
120
20
40
53
59
50-
195
75
140
225
14
38
60
80
23
46
62
69
60-
230
85
165
265
22
38
60
80
18
37
50
55
50-
70
130
185
210
14
30
50
60
21
42
57
63
60-
80
145
205
235
14
38
60
80
150
24
48
65
73
60-
90
170
240
275
22
38
60
80
28
57
77
85
80-
205
110
290
330
22
50
80
100
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6