video corpo

VAS
26Pages

{{requestButtons}}

Catalog excerpts

VAS - 1

VASSound-damped volumetric flow controller PERFORMANCE DATA TESTS AND STANDARDS • Operating temperature: 10 - 40° C • Difference pressure range 50 - 1000 Pa • Connection voltage for VAS (electronic): 24V DC/AC, ±10%, 50/60 Hz • Control signal: 0-10 V DC or 2-10 V DC • VDI 6022, Sheet 1: Hygienic requirements of ventilation and air-conditioning systems • DIN EN 13779 (2007): Ventilation of non-residential buildings • Leakage air: DIN EN 1751 (2014-06) SPECIAL FEATURES APPROVALS AND CERTIFICATES • RoHS 2002/95/EC • EMC 2004/108/EC • Low voltage 2006/95/EC • Machinery Directive 2006/42/EC • Compact dimensions and low height • Integrated high-performance silencer • High precision, easy mode of operation and reliable control • Low pressure losses • No inflow or outflow distances required. SCHAKO | Ferdinand Schad KG SteigstraRe 25-27 D-78600 Kolbingen

Open the catalog to page 1
VAS - 2

VAS – Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Table of Contents Construction subject to change. No return possible.

Open the catalog to page 2
VAS - 3

VAS – Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Description | Function | Field of application The sound-damped volumetric flow controller VAS in rectangular design is suitable for use in supply or return air systems for constant and variable volumetric flows at high acoustic requirements. The VAS achieves high control accuracy at any inflow conditions. It can also be used for controlling room or duct pressure. In VAV systems, the integrated volumetric flow controller VAS can regulate variable volumetric flows between Vmin and Vmax as a function of the supply air...

Open the catalog to page 3
VAS - 4

VAS – Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Advantages | Construction | Version| Product versions | Accessories OVERVIEW OF PRODUCT VERSIONS Compact dimensions and low height Integrated high-performance silencer High precision, easy mode of operation and reliable control Optimised for systems of low velocities Low pressure losses Significant savings in operating costs during installation For rectangular and round duct connections Low mounting and maintenance expenditure No inflow or outflow distances required. Figure 1: Supply air, left-hand model, top view...

Open the catalog to page 4
VAS - 5

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Dimensions and weights Detail Y Supply air: Return air: Duct: B = blue R = red Table 1: Weights VAS-K/ VAS-S Construction subject to change. No return possible. Version: 2017-05-08 | Page 5

Open the catalog to page 5
VAS - 6

VAS – Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Dimensions of accessories DIMENSIONS OF ACCESSORIES Transition piece (-USR) Connection to round ducts on high-pressure side for supply air or return air (to DIN EN 1506). Rubber lip seal (-GD1, for -USR only) Detail X: Metu flange Figure 6 : Rubber lip seal (-GD1) Figure 7: Connection to round ducts on high-pressure side Table 3: Connection to round ducts on high-pressure side Figure 8: Connection to rectangular ducts NW 1 2 3 4 5 Table 4: Connection to rectangular ducts Construction subject to change. No return possible....

Open the catalog to page 6
VAS - 7

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Dimensions of accessories ■CHAK# Flat-bed acoustic cladding (-FD1) Integrated into VAS- / VAS-S housing Tabel 5: Flat-bed acoustic cladding (-FD1) Table 6: Heating register Construction subject to change. No return possible.

Open the catalog to page 7
VAS - 8

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data Volumetric flow range Table 8: Static minimum pressure difference For correct operation of the controller, please note that an additional 5 Pa must be added to the static minimum pressure difference during parameter setting. Construction subject to change. No return possible.

Open the catalog to page 8
VAS - 9

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data = value below the static minimum pressure difference Table 9: Flow generated noise VAS-K-Z Construction subject to change. No return possible.

Open the catalog to page 9
VAS - 10

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data = value below the static minimum pressure difference Table 10: Flow generated noise VAS-K-A Construction subject to change. No return possible.

Open the catalog to page 10
VAS - 11

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data = value below the static minimum pressure difference Table 11: Flow generated noise VAS-S-Z Construction subject to change. No return possible.

Open the catalog to page 11
VAS - 12

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data = value below the static minimum pressure difference Table 12: Flow generated noise VAS-S-A Construction subject to change. No return possible.

Open the catalog to page 12
VAS - 13

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data Table 13: Radiated noise VAS-K-Z / VAS-S-Z / VAS-K-A / VAS-S-A Construction subject to change. No return possible.

Open the catalog to page 13
VAS - 14

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data Construction subject to change. No return possible.

Open the catalog to page 14
VAS - 15

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Technical data | Controller selection Heating register (-H2), two-row CONTROLLER SELECTION Table 15: Heating register (-H2) Other controllers available on request. Makes Belimo, Gruner, Sauter, Siemens possible. Table 17: Controller selection Heating register (-H4), four-row Table 16: Heating register (-H4) Construction subject to change. No return possible.

Open the catalog to page 15
VAS - 16

VAS - Sound-damped volumetric flow controller TECHNICAL DOCUMENTATION Circuit diagrams Circuit diagram standard controller Compact controller NMV-D3-MP (make Belimo) VAV with analogue command signal VAV with lock (CLOSED) MP-Bus activation with integrated MP / actual value sig-■*TaO ...10V/2...10V 1 VAV command signal 0...10V CLOSED / VAV mode Lock mode (CLOSED): In the 2...10 V mode, the following function can be carried out with a 0 -10 V signal: Construction subject to change. No return possible.

Open the catalog to page 16

All SCHAKO KG catalogs and technical brochures

  1. AUDIX

    2 Pages

  2. DISA

    4 Pages

  3. UC-OH²

    2 Pages

  4. IGA

    2 Pages

  5. CDD

    2 Pages

  6. FBS

    18 Pages

  7. MINOPAB

    6 Pages

  8. PIL

    23 Pages

  9. MWS / MWK

    23 Pages

  10. ERK-SO

    43 Pages

  11. BKSYS

    18 Pages

  12. MINODSA

    6 Pages

  13. DKA

    6 Pages

  14. LAQ

    11 Pages

  15. VMPR/VMPQ

    29 Pages

  16. BKA-EN

    79 Pages

  17. CPL

    15 Pages

  18. AUDIX®

    25 Pages

  19. VREX

    26 Pages

  20. VQEX

    17 Pages

  21. VPEX

    18 Pages

  22. SVA-FS

    11 Pages

  23. NRWG

    22 Pages

  24. COMBIDSC

    26 Pages

  25. DSCXL

    17 Pages

  26. DSCU

    18 Pages

  27. DSCPL

    16 Pages

  28. DSCP

    15 Pages

  29. DSC

    37 Pages

  30. DO

    10 Pages

  31. VRAQ

    46 Pages

  32. UEKU

    6 Pages

  33. UEK

    6 Pages

  34. SS-K

    6 Pages

  35. DQJP

    9 Pages

  36. VOLKOM

    6 Pages

  37. DQJ

    38 Pages

  38. ALPETY

    16 Pages

  39. CTT

    23 Pages

  40. STV

    8 Pages

  41. KWB

    19 Pages

  42. GREENKIT

    20 Pages

  43. FKU

    31 Pages

  44. FKF

    29 Pages

  45. SGA

    5 Pages

  46. DBB

    27 Pages

  47. TVO

    8 Pages

  48. AL

    23 Pages

  49. SVA-FF

    15 Pages

  50. RF

    7 Pages

  51. NBS

    34 Pages

  52. MKAR_MKAQ

    13 Pages

  53. KGF

    11 Pages

  54. KF

    4 Pages

  55. JK

    16 Pages

  56. HK

    16 Pages

  57. FLARE

    13 Pages

  58. FLAQ

    11 Pages

  59. FKW

    28 Pages

  60. FG

    14 Pages

  61. ERK-MB

    38 Pages

  62. DISA-H

    34 Pages

  63. DISA-B

    32 Pages

  64. DISA-601

    41 Pages

  65. DISA-360

    32 Pages

  66. DISA-300

    51 Pages

  67. CNVA

    32 Pages

  68. CNV

    29 Pages

  69. BSK-RPR

    60 Pages

  70. BKP-EN

    40 Pages

  71. BKA-UE

    35 Pages

  72. BAK-250

    17 Pages

  73. BAK-240

    16 Pages

  74. Aquaris-Silent

    38 Pages

  75. Aquaris_KWB

    20 Pages

  76. DISA-W

    43 Pages

  77. PILB/PILBR

    33 Pages

  78. DAV

    19 Pages

  79. 4DE

    18 Pages

  80. 4DF

    13 Pages

  81. DQC

    16 Pages

  82. DQDL

    16 Pages

  83. IDA

    21 Pages

  84. IKA

    23 Pages

  85. ZMD

    17 Pages

  86. DQF

    15 Pages

  87. DQJF

    12 Pages

  88. DQJA/DQJR

    10 Pages

  89. DQJSL

    17 Pages

  90. DQJSLC

    17 Pages

  91. DHV

    18 Pages

  92. DSARR

    7 Pages

  93. QA

    30 Pages

  94. PUSH

    23 Pages

  95. WQA

    12 Pages

  96. DSX-XXL

    23 Pages

  97. AUDIX®-ÜSG

    13 Pages

  98. SIA

    7 Pages

  99. SAR/SAQ/SARP

    13 Pages

  100. WDA

    32 Pages

  101. KGRR

    17 Pages

  102. DBBRR

    11 Pages

  103. WGARR

    7 Pages

  104. WGA

    29 Pages

  105. DKAPPs

    6 Pages

  106. EBE/EBP

    52 Pages

  107. VRAPPs

    20 Pages

  108. VRAR

    52 Pages

  109. MAK

    15 Pages

  110. DISA-Family

    4 Pages

  111. RMS

    11 Pages

  112. EasyBus

    24 Pages

  113. TSR

    5 Pages

  114. RS-F

    7 Pages

  115. RS

    15 Pages

  116. VLV

    31 Pages

  117. VARS

    26 Pages

  118. VAQS

    19 Pages

  119. PIANO

    27 Pages

  120. MBM

    10 Pages

  121. MBE/MBP

    27 Pages

  122. DKG

    6 Pages

  123. ALAS-P

    5 Pages

  124. ALAS-F 125

    6 Pages

  125. ALAS

    10 Pages

  126. ALA-SO

    4 Pages

  127. ALA-R

    4 Pages

  128. ALA

    4 Pages

  129. LL

    7 Pages

  130. RR-Complete

    41 Pages

  131. DBBR

    6 Pages

  132. PA

    32 Pages

  133. LK

    12 Pages

  134. IB-R

    15 Pages

  135. IB-Q

    21 Pages

  136. KG

    19 Pages

  137. BSG

    19 Pages

  138. DSX-XXL-W

    25 Pages

  139. AUDIX®-AW

    20 Pages

  140. DSX

    25 Pages

  141. MINODSX

    6 Pages

  142. MINODSA

    6 Pages

  143. DSA

    15 Pages

  144. COMBIPIL

    11 Pages

  145. COMBIDQJ

    11 Pages

  146. MINOPAB

    6 Pages

  147. BDA

    11 Pages

  148. SPB

    10 Pages

  149. DISA-H

    34 Pages

  150. DISA-601

    41 Pages

  151. DISA-360

    32 Pages

  152. DISA-300

    51 Pages

  153. DISA-B

    32 Pages

  154. AQUARIS SILENT

    38 Pages

  155. NBS

    24 Pages

  156. CNV

    29 Pages

  157. CNVA

    32 Pages

  158. JK-LP/JK-LU

    15 Pages

  159. HKP / HKU

    16 Pages

  160. FKW

    16 Pages

  161. FLARE

    13 Pages

  162. RF

    7 Pages

  163. KGF

    9 Pages

  164. SVA-FF

    8 Pages

  165. BKA-Ü

    35 Pages

  166. BSK-RPR

    60 Pages

  167. BKP-EN

    40 Pages

  168. BAK-240

    6 Pages

  169. BAK-250

    14 Pages

  170. KF

    4 Pages