video corpo

DISA-B
32Pages

{{requestButtons}}

Catalog excerpts

DISA-B - 2

11/30 - 2 Construction subject to change. Version: 09.05.2014 No return possible!

Open the catalog to page 2
DISA-B - 3

Floor Induction Diffuser DISA-B Description The SCHAKO floor induction diffusers of series DISA-B belong to the group of air/water systems and are suitable, thanks to their induction technology, for discharging high loads using small conditioned external air flows and the energetic benefit of load discharge (heating/cooling) by the medium water. Advantageously, DISA-B are used for room-high glazed buildings without false ceiling and low storey heights. In heating mode, draughts caused by cold air drop and surfaces emitting cold at the façade can be avoided, and in cooling mode the DISA-B...

Open the catalog to page 3
DISA-B - 4

Description of the equipment Construction Housing - Galvanised steel sheet with 1 or 2 primary air connecting pieces 098 and 0123 (standard) - Primary connection pipe position: - Horizontal (-H) - Arrangement of the primary air connecting pieces: - 1 central connecting piece (-AS1, standard) - 2 central connecting pieces and at the same distance (-AS2/ AS3) Louvre grid (-PA-3) - Extruded aluminium profile Roll-down grille (-PA-R) - Extruded aluminium profile Heat exchanger - 4-pipe system (cooling and heating) or optionally 2-pipe system (cooling or heating) - Galvanised sheet steel frame -...

Open the catalog to page 4
DISA-B - 5

Floor Induction Diffuser DISA-B Models and dimensions Dimensions and weights LG NL (mm) = nominal length (1000 / 1150 / 1300 / 1450 / 1600 / 1750 ) LG (mm) = Total length - without valve group integrated on site: (2000 > LG ≥ NL) - with valve group integrated on site: (2000 > LG ≥ NL+150) øD (mm) = diameter of the connection pipe (98 and 123) Arrangement of the connecting pieces (-AS) and water connection (-WS) Connection primary air connecting piece Weights DISA-B Number/position of the connection pipes - with horizontal connection (-H) - with 1 central connecting piece (-AS1) - with 2...

Open the catalog to page 5
DISA-B - 6

with 1 horizontal connecting piece (-AS1) 012 mm outside Position of primary air plenum box (-L) Prepunched passages for water connections -262,5 212,5 Construction subject to change. Variable dimension, depending on the configuration of the unit

Open the catalog to page 6
DISA-B - 7

Floor Induction Diffuser DISA-B Flexible armoured hose with stainless steel braid, oxygen diffusion layer to DIN 4726, one-sided by means of plug-in fitting 90° with stainless steel claw, support ring, 2 sealing rings (operating pressure 20 bar, test pressure 60 bar, temperature -40° to +80°) and lock washer, other side 1/2" spigot nut with flat seal. L= 500, 800 and 1200 mm. Other lengths on request. Adjusting legs For adjusting the device height (up to 50 mm) External thread flat-sealing Water connections 1/2" external thread flat-sealing Ball valve to shut off the register to a hydraulic...

Open the catalog to page 7
DISA-B - 8

Floor Induction Diffuser DISA-B Technical data Performance data DISA-B-H -...-B -Cooling-

Open the catalog to page 8
DISA-B - 24

11/30 - 24Construction subject to change. Version: 09.05.2014

Open the catalog to page 24
DISA-B - 25

Floor Induction Diffuser DISA-BControl units Valves 2-way valves (series VD115CLC) Nominal diameter 15 mm Connections inner and outer thread 1/2 inch thick Manual setting button/protective cap included in delivery Valve with adjustable kv by means of a ring 0.25-1.9 m3/h Drives SSA (100 N) and STA (100 N) Straight lockshields (ADN series) - Nominal diameters 10,15 and 20 mm - Connections inner and outer thread 1/2 inch - Manual setting button/protective cap included in delivery - Valve with adjustable kv by means of a ring 0.15-3 m3/h Compatible drives: (1) in connection with room...

Open the catalog to page 25
DISA-B - 26

Floor Induction Diffuser DISA-B Actuators Model SSA Model STA - Actuating power 100 N - Automatic detection of the valve stroke - Simple installation - Standard version including 1, 2 or 5 m connecting cables - Direct mounting - Manual adjustment and position indicator - Motion and position indicator - Connecting cable lengths 1.5, 2.5 and 4.5 m - Pulse duration modulation (PDM) (room temperature controls RDG and RCU) - Two-wire connection SSA31: actuator 230 V AC, 3-point activation SSA61: actuator 24 V AC/DC, activation 0...10 V DC SSA81: actuator 24 V AC, 3-point activation STA23:...

Open the catalog to page 26
DISA-B - 27

ICHAK#Floor Induction Diffuser DISA-B Model RCU 15 Control unitsModel RCU 10 2-point or steady control with PI behaviour, as desired, combined with model STA On/Off or PWM signal Operating mode switchover contact input for remote circuit Operating voltage AC 230 V Optional 2-point or steady control with PI behaviour, as desired ON/OFF or PWM actuator signal outputs Standard, Economy and Stand-by operating modes Operating mode switchover contact input for remote circuit Operating voltage AC 24 V L, N Operating voltage AC 230 V D1, GND Signal input for potential-free operating mode switch Y1,...

Open the catalog to page 27
DISA-B - 28

- Room thermostat with manual switch for heating or cooling - Two-point control behaviour - Switching voltage AC 24...250 V Connection diagram: D1 Zone valves or thermal valves L Switching voltage AC 24...250 V S Selector switch Heating / OFF / Cooling Y Control output "Heating" or "Cooling", AC 24...250 V N Operating voltage zero - Display with backlight - Automatic switchover between heating and cooling mode via sensor QAH11.1 (optional) - Operating modes: Comfort, Economy and Protective modes - PWM regulation, optional - Automatic mode with timer program - Optional RDG KNX communication...

Open the catalog to page 28
DISA-B - 29

QXA2602 QXA2604 - Operating voltage AC/DC 24 V or AC 230 V - Potential-free changeover contact AC/DC 1...30V or AC 230V - Quick and simple installation - Flat or pre-assembly - Integrated and remote sensor available - Status display via two-colour LED Mode of action: The condensation monitor detects the relative humidity near the dew point (= 100% of r. h.) via its moisture-sensitive element. During this detection, the resistance value of the element increases considerably between 90 ... 100% of r. h. Before reaching the dew point, the electronics of the relay switches. A changeover of the...

Open the catalog to page 29
DISA-B - 30

Floor Induction Diffuser DISA-B Assembly The DISA-B series is suitable for horizontal assembly in false floors. Thanks to the adjustable legs and the mounting plates, the DISA-B can also be levelled from the room side, after completed assembly. The floor induction diffuser DISA-Bis particulary maintenance-friendly. Grille, register and plenum box are cleaned with an industrial vacuum cleaner or steam cleaner or by spraying it with Apmax (kPa) a non-aggressive cleaner. Nominal length Total length Primary air flow Standard amount of water flow Static pressure Water-side pressure loss Primary...

Open the catalog to page 30

All SCHAKO KG catalogs and technical brochures

  1. AUDIX

    2 Pages

  2. DISA

    4 Pages

  3. UC-OH²

    2 Pages

  4. IGA

    2 Pages

  5. CDD

    2 Pages

  6. FBS

    18 Pages

  7. MINOPAB

    6 Pages

  8. PIL

    23 Pages

  9. MWS / MWK

    23 Pages

  10. ERK-SO

    43 Pages

  11. BKSYS

    18 Pages

  12. MINODSA

    6 Pages

  13. DKA

    6 Pages

  14. LAQ

    11 Pages

  15. VMPR/VMPQ

    29 Pages

  16. BKA-EN

    79 Pages

  17. CPL

    15 Pages

  18. AUDIX®

    25 Pages

  19. VREX

    26 Pages

  20. VQEX

    17 Pages

  21. VPEX

    18 Pages

  22. SVA-FS

    11 Pages

  23. NRWG

    22 Pages

  24. COMBIDSC

    26 Pages

  25. DSCXL

    17 Pages

  26. DSCU

    18 Pages

  27. DSCPL

    16 Pages

  28. DSCP

    15 Pages

  29. DSC

    37 Pages

  30. DO

    10 Pages

  31. VRAQ

    46 Pages

  32. UEKU

    6 Pages

  33. UEK

    6 Pages

  34. SS-K

    6 Pages

  35. DQJP

    9 Pages

  36. VOLKOM

    6 Pages

  37. DQJ

    38 Pages

  38. ALPETY

    16 Pages

  39. CTT

    23 Pages

  40. STV

    8 Pages

  41. KWB

    19 Pages

  42. GREENKIT

    20 Pages

  43. FKU

    31 Pages

  44. FKF

    29 Pages

  45. SGA

    5 Pages

  46. DBB

    27 Pages

  47. TVO

    8 Pages

  48. AL

    23 Pages

  49. SVA-FF

    15 Pages

  50. RF

    7 Pages

  51. NBS

    34 Pages

  52. MKAR_MKAQ

    13 Pages

  53. KGF

    11 Pages

  54. KF

    4 Pages

  55. JK

    16 Pages

  56. HK

    16 Pages

  57. FLARE

    13 Pages

  58. FLAQ

    11 Pages

  59. FKW

    28 Pages

  60. FG

    14 Pages

  61. ERK-MB

    38 Pages

  62. DISA-H

    34 Pages

  63. DISA-B

    32 Pages

  64. DISA-601

    41 Pages

  65. DISA-360

    32 Pages

  66. DISA-300

    51 Pages

  67. CNVA

    32 Pages

  68. CNV

    29 Pages

  69. BSK-RPR

    60 Pages

  70. BKP-EN

    40 Pages

  71. BKA-UE

    35 Pages

  72. BAK-250

    17 Pages

  73. BAK-240

    16 Pages

  74. Aquaris-Silent

    38 Pages

  75. Aquaris_KWB

    20 Pages

  76. DISA-W

    43 Pages

  77. PILB/PILBR

    33 Pages

  78. DAV

    19 Pages

  79. 4DE

    18 Pages

  80. 4DF

    13 Pages

  81. DQC

    16 Pages

  82. DQDL

    16 Pages

  83. IDA

    21 Pages

  84. IKA

    23 Pages

  85. ZMD

    17 Pages

  86. DQF

    15 Pages

  87. DQJF

    12 Pages

  88. DQJA/DQJR

    10 Pages

  89. DQJSL

    17 Pages

  90. DQJSLC

    17 Pages

  91. DHV

    18 Pages

  92. DSARR

    7 Pages

  93. QA

    30 Pages

  94. PUSH

    23 Pages

  95. WQA

    12 Pages

  96. DSX-XXL

    23 Pages

  97. AUDIX®-ÜSG

    13 Pages

  98. SIA

    7 Pages

  99. SAR/SAQ/SARP

    13 Pages

  100. WDA

    32 Pages

  101. KGRR

    17 Pages

  102. DBBRR

    11 Pages

  103. WGARR

    7 Pages

  104. WGA

    29 Pages

  105. DKAPPs

    6 Pages

  106. EBE/EBP

    52 Pages

  107. VRAPPs

    20 Pages

  108. VRAR

    52 Pages

  109. MAK

    15 Pages

  110. DISA-Family

    4 Pages

  111. RMS

    11 Pages

  112. EasyBus

    24 Pages

  113. TSR

    5 Pages

  114. RS-F

    7 Pages

  115. RS

    15 Pages

  116. VLV

    31 Pages

  117. VARS

    26 Pages

  118. VAQS

    19 Pages

  119. VAS

    26 Pages

  120. PIANO

    27 Pages

  121. MBM

    10 Pages

  122. MBE/MBP

    27 Pages

  123. DKG

    6 Pages

  124. ALAS-P

    5 Pages

  125. ALAS-F 125

    6 Pages

  126. ALAS

    10 Pages

  127. ALA-SO

    4 Pages

  128. ALA-R

    4 Pages

  129. ALA

    4 Pages

  130. LL

    7 Pages

  131. RR-Complete

    41 Pages

  132. DBBR

    6 Pages

  133. PA

    32 Pages

  134. LK

    12 Pages

  135. IB-R

    15 Pages

  136. IB-Q

    21 Pages

  137. KG

    19 Pages

  138. BSG

    19 Pages

  139. DSX-XXL-W

    25 Pages

  140. AUDIX®-AW

    20 Pages

  141. DSX

    25 Pages

  142. MINODSX

    6 Pages

  143. MINODSA

    6 Pages

  144. DSA

    15 Pages

  145. COMBIPIL

    11 Pages

  146. COMBIDQJ

    11 Pages

  147. MINOPAB

    6 Pages

  148. BDA

    11 Pages

  149. SPB

    10 Pages

  150. DISA-H

    34 Pages

  151. DISA-601

    41 Pages

  152. DISA-360

    32 Pages

  153. DISA-300

    51 Pages

  154. AQUARIS SILENT

    38 Pages

  155. NBS

    24 Pages

  156. CNV

    29 Pages

  157. CNVA

    32 Pages

  158. JK-LP/JK-LU

    15 Pages

  159. HKP / HKU

    16 Pages

  160. FKW

    16 Pages

  161. FLARE

    13 Pages

  162. RF

    7 Pages

  163. KGF

    9 Pages

  164. SVA-FF

    8 Pages

  165. BKA-Ü

    35 Pages

  166. BSK-RPR

    60 Pages

  167. BKP-EN

    40 Pages

  168. BAK-240

    6 Pages

  169. BAK-250

    14 Pages

  170. KF

    4 Pages