CNV - 1

TECHNICAL DOCUMENTATION SCHAKO | Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen

Open the catalog to page 1
CNV - 2

TECHNICAL DOCUMENTATION General description GENERAL DESCRIPTION SCHAKO's passive floor convectors CNV as decentralised airconditioners (heating mode) enable energy-efficient and comfortable air-conditioning of offices and administration buildings, exhibition and sales rooms, private living spaces, and conservatories. Passive floor convectors work by the principle of natural convection. Cold air close to the floor flows into the convector, is heated by the heat exchanger and flows upwards. The main area of use of floor convectors of this type is as addition to other heating systems and as an...

Open the catalog to page 2
CNV - 3

CNV - Floor convector TECHNICAL DOCUMENTATION Description of the equipment MODELS 1 - Housing — Made of galvanised sheet steel, painted internally and externally to RAL 9005 (black), with pre-marked connection openings for hydraulic connections. Total length up to < 4000 mm Band design: — without end pieces (-E0) — with 1 end piece on the right (-ER) --- with 1 end piece on the left (-EL) Single convector with 2 end pieces (-E2) (standard) Housing outside: --- painted to RAL 9005 (black) (-A1) (standard) --- painted with polyester powder as rust protection (-A2) — With impact sound...

Open the catalog to page 3
CNV - 4

CNV - Floor convector TECHNICAL DOCUMENTATION Construction and Dimensions ATTENTION For all dimensions given, the dimensions of projecting fastening elements have not been taken into account. * Dry weight per metre with linear grille, frame, spacer bridges and water register, without connections. Table 1: Constructive features CNV Construction subject to change. Return not possible. Version: 2017-03-09 | Page 4

Open the catalog to page 4
CNV - 5

TECHNICAL DOCUMENTATION Construction and Dimensions TOTAL LENGTH AND REGISTER POSITION All passive floor convectors can be lengthened with inactive parts to a total length (-LG) of ≤4000 to adjust them to the structural conditions or to adjust them architecturally. Additional flexibility is achieved by having the option of selecting the register position. xxxx = Total length (LG) --- Nominal length up to < 4000 mm --- The total length (LG) must be entered with 4 digits. The position of the floor convector in the housing depends on the total length, the following options being possible:...

Open the catalog to page 5
CNV - 6

TECHNICAL DOCUMENTATION Construction and Dimensions Upper frame: The tread-resistant grille of the passive floor convectors CNV consists of a linear grille or a roll-down grille (optional) which, fitted in a frame and reinforced with several spacer bridges, serves for transmitting and distributing the load uniformly all the way to the adjusting legs. G1 = Extruded aluminium profiles natural colour anodised E6/EV1 G2 = Extruded aluminium profiles black anodised E6/EV6 G3 = Extruded aluminium profiles bronze anodised E6/C33 SCHAKO linear grille PA: L1 = Linear grille aluminium natural colour...

Open the catalog to page 6
CNV - 7

CNV - Floor convector TECHNICAL DOCUMENTATION Construction and Dimensions PRIMARY AIR CONNECTION SPIGOT In the complete CNV series, additional spigots with air diffuser plates for introducing conditioned fresh air can be used for covering all possible air-conditioning needs. Spigot diameter: PI = Width of rectangular spigot = as ordered, without GD Rubber lip seal (-GD) Rubber lip seal for the primary air connection spigot for airtight connection between device and duct. Table 2: Possible primary air connection spigots Primary air connection spigot position 1 = Primary air connection spigot...

Open the catalog to page 7
CNV - 8

TECHNICAL DOCUMENTATION Connection CONNECTION POSITION W1 = Left end face (standard) W2 = Right end face W3 = Left front face - Room side W4 = Right front face - Room side The housings of the floor convectors CNV are pre-punched for various positions of the electrical and hydraulic connections, thus facilitating installation. Facade side Room side Figure 19: Connection position for type CNV 190 Figure 18: Connection side Model B = 270 mm Room side (-W3/-W4) ATTENTION The position of the water connections and the position of the primary air connection spigot without housing extension must...

Open the catalog to page 8
CNV - 9

CNV - Floor convector TECHNICAL DOCUMENTATION ConnectionModel B = 350 mm End face (-W1/-W2) Room side (-W3/-W4) Model B = 400 mm End face (-W1/-W2) Room side (-W3/-W4) Construction subject to change. Return not possible.

Open the catalog to page 9
CNV - 10

CNV - Floor convector TECHNICAL DOCUMENTATION Connection WATER CONNECTION Plug fitting male thread Actuators Rotating plug fitting with male thread K" flatsealing. Fitting body made of brass, sealing rings made of rubber and clamping ring made of stainless steel. Figure 23: Plug fitting male thread Eurocone connections Spigot nut female thread %" Eurocone for copper pipe 15. Model STA — Actuating power 100 N --- Simple installation --- Standard version prewired --- Motion and position indicator — Two-/ three-wire connection — Pulse width modulation (PDM) — STA23:Actuator thermal, operating...

Open the catalog to page 10
CNV - 11

CNV - Floor convector TECHNICAL DOCUMENTATION Connection WATER CONNECTION OPTIONS 6 = Straight-through valve, shut-off valve and actuator _continuous 24V (motorised), LGmin=NL+100 mm Construction subject to change. Return not possible. Version: 2017-03-09 | Page 11

Open the catalog to page 11
CNV - 12

TECHNICAL DOCUMENTATION Closed-circuit and open-circuit control system CLOSED-CIRCUIT AND OPEN-CIRCUIT CONTROL SYSTEM ELECTRICAL JUNCTION BOX Connecting a CNV unit Figure 34: Connecting a CNV unit Connecting several CNV units Figure 35: Connecting several CNV units without electric junction box (standard) Electric junction box, with terminal strip, internally prewired * ATTENTION When using the floor convectors CNV in parallel, the load limits of the control and power consumption of the floor convectors must be taken into account. If the floor convectors CNV are controlled via actuators...

Open the catalog to page 12
CNV - 13

CNV - Floor convector TECHNICAL DOCUMENTATION Models END PIECE The CNVs can be installed individually or in band design with an end piece on both sides, only on the right or only on the left, or without an end piece.. EO = Band design, central part without end piece ATTENTION For perfect alignment of the units, the four connecting parts should be installed and fastened using the delivered screws. EXTERNAL COATING Housing painted externally to RAL9005 (-A1) (standard), or painted with polyester powder as rust protection (-A2). Optional: Impact-sound insulation made of 3-mm polyethylene on...

Open the catalog to page 13

All SCHAKO KG catalogs and technical brochures

  1. AUDIX

    2 Pages

  2. DISA

    4 Pages

  3. UC-OH²

    2 Pages

  4. IGA

    2 Pages

  5. CDD

    2 Pages

  6. FBS

    18 Pages

  7. MINOPAB

    6 Pages

  8. PIL

    23 Pages

  9. MWS / MWK

    23 Pages

  10. ERK-SO

    43 Pages

  11. BKSYS

    18 Pages

  12. MINODSA

    6 Pages

  13. DKA

    6 Pages

  14. LAQ

    11 Pages

  15. VMPR/VMPQ

    29 Pages

  16. BKA-EN

    79 Pages

  17. CPL

    15 Pages

  18. AUDIX®

    25 Pages

  19. VREX

    26 Pages

  20. VQEX

    17 Pages

  21. VPEX

    18 Pages

  22. SVA-FS

    11 Pages

  23. NRWG

    22 Pages

  24. COMBIDSC

    26 Pages

  25. DSCXL

    17 Pages

  26. DSCU

    18 Pages

  27. DSCPL

    16 Pages

  28. DSCP

    15 Pages

  29. DSC

    37 Pages

  30. DO

    10 Pages

  31. VRAQ

    46 Pages

  32. UEKU

    6 Pages

  33. UEK

    6 Pages

  34. SS-K

    6 Pages

  35. DQJP

    9 Pages

  36. VOLKOM

    6 Pages

  37. DQJ

    38 Pages

  38. ALPETY

    16 Pages

  39. CTT

    23 Pages

  40. STV

    8 Pages

  41. KWB

    19 Pages

  42. GREENKIT

    20 Pages

  43. FKU

    31 Pages

  44. FKF

    29 Pages

  45. SGA

    5 Pages

  46. DBB

    27 Pages

  47. TVO

    8 Pages

  48. AL

    23 Pages

  49. SVA-FF

    15 Pages

  50. RF

    7 Pages

  51. NBS

    34 Pages

  52. MKAR_MKAQ

    13 Pages

  53. KGF

    11 Pages

  54. KF

    4 Pages

  55. JK

    16 Pages

  56. HK

    16 Pages

  57. FLARE

    13 Pages

  58. FLAQ

    11 Pages

  59. FKW

    28 Pages

  60. FG

    14 Pages

  61. ERK-MB

    38 Pages

  62. DISA-H

    34 Pages

  63. DISA-B

    32 Pages

  64. DISA-601

    41 Pages

  65. DISA-360

    32 Pages

  66. DISA-300

    51 Pages

  67. CNVA

    32 Pages

  68. CNV

    29 Pages

  69. BSK-RPR

    60 Pages

  70. BKP-EN

    40 Pages

  71. BKA-UE

    35 Pages

  72. BAK-250

    17 Pages

  73. BAK-240

    16 Pages

  74. Aquaris-Silent

    38 Pages

  75. Aquaris_KWB

    20 Pages

  76. DISA-W

    43 Pages

  77. PILB/PILBR

    33 Pages

  78. DAV

    19 Pages

  79. 4DE

    18 Pages

  80. 4DF

    13 Pages

  81. DQC

    16 Pages

  82. DQDL

    16 Pages

  83. IDA

    21 Pages

  84. IKA

    23 Pages

  85. ZMD

    17 Pages

  86. DQF

    15 Pages

  87. DQJF

    12 Pages

  88. DQJA/DQJR

    10 Pages

  89. DQJSL

    17 Pages

  90. DQJSLC

    17 Pages

  91. DHV

    18 Pages

  92. DSARR

    7 Pages

  93. QA

    30 Pages

  94. PUSH

    23 Pages

  95. WQA

    12 Pages

  96. DSX-XXL

    23 Pages

  97. AUDIX®-ÜSG

    13 Pages

  98. SIA

    7 Pages

  99. SAR/SAQ/SARP

    13 Pages

  100. WDA

    32 Pages

  101. KGRR

    17 Pages

  102. DBBRR

    11 Pages

  103. WGARR

    7 Pages

  104. WGA

    29 Pages

  105. DKAPPs

    6 Pages

  106. EBE/EBP

    52 Pages

  107. VRAPPs

    20 Pages

  108. VRAR

    52 Pages

  109. MAK

    15 Pages

  110. DISA-Family

    4 Pages

  111. RMS

    11 Pages

  112. EasyBus

    24 Pages

  113. TSR

    5 Pages

  114. RS-F

    7 Pages

  115. RS

    15 Pages

  116. VLV

    31 Pages

  117. VARS

    26 Pages

  118. VAQS

    19 Pages

  119. VAS

    26 Pages

  120. PIANO

    27 Pages

  121. MBM

    10 Pages

  122. MBE/MBP

    27 Pages

  123. DKG

    6 Pages

  124. ALAS-P

    5 Pages

  125. ALAS-F 125

    6 Pages

  126. ALAS

    10 Pages

  127. ALA-SO

    4 Pages

  128. ALA-R

    4 Pages

  129. ALA

    4 Pages

  130. LL

    7 Pages

  131. RR-Complete

    41 Pages

  132. DBBR

    6 Pages

  133. PA

    32 Pages

  134. LK

    12 Pages

  135. IB-R

    15 Pages

  136. IB-Q

    21 Pages

  137. KG

    19 Pages

  138. BSG

    19 Pages

  139. DSX-XXL-W

    25 Pages

  140. AUDIX®-AW

    20 Pages

  141. DSX

    25 Pages

  142. MINODSX

    6 Pages

  143. MINODSA

    6 Pages

  144. DSA

    15 Pages

  145. COMBIPIL

    11 Pages

  146. COMBIDQJ

    11 Pages

  147. MINOPAB

    6 Pages

  148. BDA

    11 Pages

  149. SPB

    10 Pages

  150. DISA-H

    34 Pages

  151. DISA-601

    41 Pages

  152. DISA-360

    32 Pages

  153. DISA-300

    51 Pages

  154. DISA-B

    32 Pages

  155. AQUARIS SILENT

    38 Pages

  156. NBS

    24 Pages

  157. CNVA

    32 Pages

  158. JK-LP/JK-LU

    15 Pages

  159. HKP / HKU

    16 Pages

  160. FKW

    16 Pages

  161. FLARE

    13 Pages

  162. RF

    7 Pages

  163. KGF

    9 Pages

  164. SVA-FF

    8 Pages

  165. BKA-Ü

    35 Pages

  166. BSK-RPR

    60 Pages

  167. BKP-EN

    40 Pages

  168. BAK-240

    6 Pages

  169. BAK-250

    14 Pages

  170. KF

    4 Pages