4 Flue and Appliance Preparation
4.9 Air Duct/Terminal and Flue Duct Assembly
Locate the flue duct into the air duct/terminal, see diagram 4.10.Take the flue manifold from the loose items pack together withthe sealant. Place the sealant onto the flue manifold.Fully locate the flue manifold in to the air duct/terminal and flueduct assembly as shown in diagram 4.10, make sure the correct
alignment of the “Top”s.Drill two 3mm diameter holes through the air duct/terminal to theflue manifold secure with the two self tapping screws supplied
in the loose items pack.It should now not be possible to remove the manifold. >
4616 4.10 Rear Fitting
Fit the self adhesive foam seal provided in the flue pack aroundthe air duct/terminal at the position shown in diagram 4.13. >
4.11 Side Fitting
Fit the self adhesive foam seal around the air duct/terminal such
that, when installed, the seal will be within the wall, see diagram
4.14.If dimension "A" is greater than 75mm from the wall, the selfadhesive foam seal can be dispensed with, and the area around
the flue made good in the normal way, see diagram 4.14.Important: If the wall liner kit is used the self adhesive foam sealincluded in the wall liner kit must be used in place of the one
supplied with the flue pack, see diagram 4.11 for position of self
adhesive seal. AIR DUCT/TERMINALAND FLUE DUCT
ASSEMBLY >
6830 STANDARDFLUE
TERMINAL Diagram 4.9
BOILERCENTRELINE
LONG FLUETERMINAL Diagram 4.10
221656D 16 >