4 Flue and Appliance Preparation
4.6 Wall Mounting Bracket
Reposition the template, making sure of dimensional alignmentwith the flue hole.Mark the boiler fixing points and mounting bracket position, seediagram 4.5.Drill holes and plug, to suit No.12x2in wood screws, fit thescrews allowing sufficient clearance, about 5mm, to accept the
swing brackets, see diagram 4.5.Secure the mounting bracket to the wall with No.12x2in woodscrews and plugs, see diagram 4.5. 4.7 Flue Duct
Mark the duct to the length required, this length allows for
expansion, see diagram 4.6 for rear flue and diagram 4.7 for
side flue, then cut square and remove any burrs. 4.8 Air Duct/Terminal
Mark the duct length, see diagram 4.8 for rear flue and diagram
4.9 for side flue, then cut square and remove any burrs. Diagram 4.7 >
6829 6833
6831 FLUEDUCT
BOILERCENTRELINET MINUS 188mm STANDARD FLUETERMINALQ PLUS 5mm
Q Q Diagram 4.6 Diagram 4.8
LONG FLUETERMINAL >
15 221656D