SAFETY DEVICES

IMPORTANT : OPALIS 6 MODELS It is forbidden to bypass or tamperwith any of the safety devices. If, after attempting to use the heater, a safety shut-down condition occurs, this must be rectified immediately by a qualified, competent person. The heater is fitted with a flue safety device. In the event of total or partial obstruction of the flue system or detrimental downdraught into the heater, the safety device will shut off the heater requiring a manual re-start. Restarting the heater must only be carried out after waiting 15 minutes. Repeated safety shutdown must be dealt with by a qualified, competent person. Dismantle the deflector and place the test-mesh bottom plate at the top of the heat exchanger Ignite the pilot and leave the pilot to operatefor a minimum of 2 minutes start the appliance and check that the com-plete extinction of the appliance takes place in a time less than or equal to 40 seconds replace the test mesh bottom plate with thedeflector.