Text version of the page
FIXING JIG THEMA F 23 E
From left to right, the fixing jig comprises: A -Heating return with isolating valve ( m ). B -Cold water inlet with isolating valve ( p ). C -Heating flow with isolating valve ( q ),drain screw ( >
5555 r ) and safety valve ( s ). >
23113
D -Domestic hot water out. E -Gas service cock. >
34
57,557,5 25 33
m 1235674 p r A q B s C
Pla 105c D E
Filters and washers : 1-Washer
2-Metal filter
3-Flow regulator
4-Plastic filter
5, 6 & 7-Washers >
THEMA F SB 18
THEMA F SB 23 E
From left to right, the fixing jig comprises: A -Heating return with isolating valve ( m ). C -Heating flow with isolating valve ( q ),drain screw ( r ) and safety valve ( s ). E -Gas service cock. >
23113 25
115110 23
m 1257 rp A q s
Pla 116b C E
Diagram 5 DOMESTIC HOT WATER SYSTEM DESIGN
•Copper tubing or plastic Hep >
2 O may be usedfor the domestic hot water system. Unnecessary
pressure losses should be avoided.•The boiler may operate with a minimum supplypressure of 0,3 bar but under a reduced flow rate.
Optimum performance will be obtained from a
supply pressure of 1 bar.•The flow restrictor must be fitted in the cold wa-ter inlet during installation. This limits the flow through
the boiler to a maximum of 12 l/min. 7 >