REPLACEMENT OF PARTS
To replace safety valve •Drain down entire heating system.
•From below boiler, disconnect heating flow pipe
from rear of fixing jig.
•Undo heating flow connection on front of fixing
jig. Remove clip from heating flow pipe connec-
tion on right of front section of reversing valve. Pull
pipe towards right and out of reversing valve. Re-
move pipe from boiler and keep.
•From below boiler, disconnect safety valve dis-
charge pipe.
•Working through boiler from the front using a long
screwdriver, undo and remove screw holding safety
valve assembly to fixing jig.
•Remove complete safety valve assembly from
fixing jig and remove from boiler.
•Fit replacement safety valve in reverse order to
removal. >
Diagram 37 23 >