REAR OUTLET FLUE INSTALLATION

Extended flue Saunier Duval partnumber 85091. These are connected together by push fit type joints, clamps and seals. The horizontal flue is extended by using one or more of the 1000 mm extension pipes, Calculation of flue cutting lengths for extended flue •Using the correct number of extension kits as ta-ble 2 , measure dimensions a and e , see diagram13 or 14. Cut both the inner and outer pipe to thedimensions given in table 3.Important:

Cutting lengthOuter pipeInner pipe

All cutting lengths should be measuredfrom the push fit end of the extension pipe. Do not leave any burrs or sharp edges on the cut ends of the pipes. Installation of flue assembly-direct rear flue •Fit rubber sealing collar ( C ) into groove at theouter end of pipe ( Installation of flue assembly-side flue A H ), ) onto outer pipe.•Take hold of inner flue,twist clockwise and push gently onto fan outlet. •Pull rubber sleeve onto boiler spigot ensuring a good seal. see diagram 16. see diagram16. •Fit rubber sealing collar ( •Fit outer pipe ( •Fit internal plastic flange ( A ) into wall with groove to theoutside. •Pull pipe inwards to bring rubber sealing collar hard up against external wall, F C ) onto outer pipe. Pushalong the pipe until engaged against internal wall. •From inside, insert inner pipe ( ) into groove at theouter end of pipe ( B ) into outer pipeturning anti-clockwise to allow inner to fully enter outer pipe. •Fit rubber sleeve ( A H ), ) onto outer pipe.•Fit both 'O' rings see diagram 16. see diagram16. •Fit outer pipe ( •Fit internal plastic flange ( A ) into wall with groove to theoutside. •Pull pipe inwards to bring rubber sealing collar hard up against external wall, (F) into flue elbow F ) onto outer pipe. Pushalong the pipe until engaged against internal wall. •From inside, push inner pipe ( B ) into outer pipeturning anti-clockwise to allow inner to fully enter outer pipe. •Fit rubber sleeve ( (D) , one atthe inlet, one at the outlet. By necessity, they are a loose fit, apply a small amount of silicone grease to each 'O' ring when fitting.

Cutting length

Important : If the flue has been cut, ensure that thereare no burrs that could damage the 'O' ring.•Remove the backing from the self adhesive gas-ket
Ven 089 (G) .•Take hold of inner flue, twist clockwise and push gently onto the elbow outlet taking care not to tear the 'O' ring. •Pull rubber sleeve onto elbow ensuring a good seal.
Diagram 15 (J) and carefully fit gasket to base of flue el-bow. •Fit elbow onto boiler and secure with the four screws
Table 2Number of extension kits required Flue optionDimension 'X'No. ofextension kits Side flue1081 to 1811mm1 (left or right)1812 to 2542 mm2 Table 3Extended flue cutting lengths Cutting length (mm)Flue optionouter pipeinner pipeComments Rear outlete + a - 906e + a + 829maximumSide flue todistance 'X' leftwithout (Diagram 13)extension1080 mm Rear outlete + a - 848e + a + 771maximum Side flue todistance 'x' rightwithout (Diagram 14)extension 1080 mm Diagram 16 Pho 087 12
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
pdf-page pdf ae En 2008-10-41-11