A ' , see diagram 18 :CLOCKWISE: To increase the pressure.
ANTICLOCKWISE: To decrease the pressure. see diagram 6 >
SETTINGS
Maximum setting . Any bypass must be fitted beforesystem controls. •Reconnect the electrical connector removed
from the modulating gas valve coil.
•Remove the protective cover from the gas valve
adjuster.
•Turn nut ' Bypass Gas valve setting Minimum setting The Commissioning THELIA 30 E has a built-in bypass. This must beadjusted according to the requirements of the sys-
tem, refer to the flow rate pressure curve ( '.•Turn the OFF/Summer/Winter switch to the 'Sum-
mer' position.
•Turn the domestic hot water temperature ad-
juster to maximum setting.
•Remove the protective cover from the gas valve
adjuster.
•Turn nut ' see diagram 18 diagram4 .•Connect a suitable pressure gauge as described
in ' >
Diagram 18 All boilers are tested and factory set during manu-
facture. Should it be necessary to reset a gas valve,
for example after replacement, proceed as follows:
•Shut down boiler. •Remove one electrical connector from the
modulating gas valve coil, ). The boiler is supplied with the built-in bypassopen a half a turn. It is adjusted by turning the by-
pass screw, see diagram 19 . Turn the screw clock-wise to close the bypass.
When using thermostatic
radiator valves (TRV's), it
is recommended that an additional, adjustable
bypass of 15 mm minimum diameter is fitted be-
tween the flow and return of the heating circuit, >
Reg 020Reg 046 Diagram 19 Diagram 19 CHANGING GAS TYPE
Should it become necessary to change the gas type, a modification kit will be required.This modification must only be carried out by a suitably qualified engineer.Conversion: Natural Gas (G20) to G30/G31Part No.85402Conversion: Natural Gas (G20) to G130Part No.85205 15 >