ELECTRICAL INSTALLATION
14 . Saunier Duval partnumber 40010. Please contact your supplier. WARNING. This boiler must be earthed.All system components shall be of an approved type.Connection of the whole electrical system and anyheating system controls to the electrical supply must
be through a common isolator.Isolation should preferably be by a double pole swit-ched fused spur box having a minimum contact
separation of 3 mm on each pole. The fused spur box
should be readily accessible and preferably adja-
cent to the boiler. It should be identified as to its use.Connect the integral supply lead, coiled and tuckedbehind the boiler, to the mains supply. All models Do not interrupt the supply with a time switch or pro-
grammer. In case of difficulty obtaining a suitable timeclock/
room thermostat, a programmable room thermostat
is available as an accessory, 14 .ON NO ACCOUNT must any electrical voltage be
applied to any of the terminals of the external con-
trols plug.
For use with a timeswitch or timeswitch and room
thermostat see diagram 14 WARNING. ON NO ACCOUNT MUST ANY EXTERNALVOLTAGE BE APPLIED TO ANY OF THE TERMINALS ON
THE HEATING CONTROLS CONNECTION PLUG.Warning : .A 230V room thermostat can be used but do not
make any connection to the compensating resistor,
see diagram Saunier Duval guarantee. This appliance must be wired in accord-ance with these instructions. Any fault arising from in-
correct wiring cannot be put right under the terms of
the Important : The integral mains supply lead is specific tothe boiler. A replacement can be obtained by quo-
ting part number 57037.A fused three pin plug and socked outlet may beused instead of the fused spur box provided that, External controls The boiler will work for heating without a room ther-
mostat and/or timeswitch being connected provid-
ed that the wire link fitted between the top two ter-
minals of the connector is left in place, see diagram a) b) They are not used in a room contaning a fixed bathor shower Both the plug and socket comply with the currentissue of BS 1363.The mains electrical supply must be maintained at alltimes in order to provide correct operation of the
boiler. >
No external controls
Room thermostat only
Room thermostat and time clock
EXTERNAL CONTROLS CONNECTIONS Factoryfitted lin k
Warning :- All external controls must be voltage free
- On no account must any external voltage
be applied to any of the external controls
plug terminals >
Boilerconnector Voltage free room
thermostat
Time clockDo notconnectExternal controlsplug Voltage free room
thermostatDo notconnect External
controls plug
Diagram 14 12 >