ELECTRICAL INSTALLATION

14 . Saunier Duval partnumber 40010. Please contact your supplier. WARNING. This boiler must be earthed.All system components shall be of an approved type.Connection of the whole electrical system and anyheating system controls to the electrical supply must be through a common isolator.Isolation should preferably be by a double pole swit-ched fused spur box having a minimum contact separation of 3 mm on each pole. The fused spur box should be readily accessible and preferably adja- cent to the boiler. It should be identified as to its use.Connect the integral supply lead, coiled and tuckedbehind the boiler, to the mains supply. All models Do not interrupt the supply with a time switch or pro- grammer. In case of difficulty obtaining a suitable timeclock/ room thermostat, a programmable room thermostat is available as an accessory, 14 .ON NO ACCOUNT must any electrical voltage be applied to any of the terminals of the external con- trols plug. For use with a timeswitch or timeswitch and room thermostat see diagram 14 WARNING. ON NO ACCOUNT MUST ANY EXTERNALVOLTAGE BE APPLIED TO ANY OF THE TERMINALS ON THE HEATING CONTROLS CONNECTION PLUG.Warning : .A 230V room thermostat can be used but do not make any connection to the compensating resistor, see diagram Saunier Duval guarantee. This appliance must be wired in accord-ance with these instructions. Any fault arising from in- correct wiring cannot be put right under the terms of the Important : The integral mains supply lead is specific tothe boiler. A replacement can be obtained by quo- ting part number 57037.A fused three pin plug and socked outlet may beused instead of the fused spur box provided that, External controls The boiler will work for heating without a room ther- mostat and/or timeswitch being connected provid- ed that the wire link fitted between the top two ter- minals of the connector is left in place, see diagram a) b) They are not used in a room contaning a fixed bathor shower Both the plug and socket comply with the currentissue of BS 1363.The mains electrical supply must be maintained at alltimes in order to provide correct operation of the boiler.

No external controls Room thermostat only Room thermostat and time clock

EXTERNAL CONTROLS CONNECTIONS

Factoryfitted lin k

Warning :- All external controls must be voltage free - On no account must any external voltage be applied to any of the external controls plug terminals

Boilerconnector Voltage free room thermostat Time clockDo notconnectExternal controlsplug Voltage free room thermostatDo notconnect External controls plug

Diagram 14 12
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
pdf-page pdf ae En 2008-10-41-10