ELECTRICAL CONNECTION
Warning. This boiler must be earthedAll system components must be of an approved
type.Connection of the whole electrical system and anyheating system controls to the electrical supply must
be through a common isolator.
Isolation should preferably be by a double pole
switched fused spur box having a minimum contact
separation of 3 mm on each pole. The fused spur
box should be readily accessible and preferably
adjacent to the boiler. It should be identified as to
its use.
A fused three pin plug and shuttered socket outlet
may be used instead of a fused spur box provided
that: External control connector
Boiler's 230 V mains lead :- brown wire : line / blue wire : neutral / yellow and green wire : earth E Warning : you must respect the line / neutral connections to the 230 V mains supply. Fig. 9a Sch 151 No external controlsRoom thermostat onlyRoom thermostat and time clock Voltage free roomthermostat
Time clock
Do notconnect 1 2 >
Do not
connect 3 1 1 >
Factory fitted linkVoltage free roomthermostat 2 2 3 3 1 >
Green wireRed wireWhite wire 2 3 >
Warning : - All external controls must be voltage free
- On no account must any external voltage be
applied to any of the external controls plug terminals Diagram 14 Sch 152 13