FLUE INSTALLATION
Table 4 :
Flue extension cutting lengths
Outer pipe
Flue option
Cutting 1er outer pipe
gth (mm) inner pipe
Comments
Side flue (right)
e + a - 555
e + a - 555
maximum dimension "X" without extension 990 mm
Side flue (left)
e + a - 825
e + a - 825
maximum dimension "X" without extension 990 mm
Cutting length
Terminal end
Inner pipe
Cutting length
Diagram 10
Installation of flue assembly
• Fit rubber sealing collar (A) into groove at the outer end of pipe (B).
• Fit outer pipe (B) into wall with groove to the outside.
• Pull pipe inwards to bring rubber sealing collar hard up against external wall, see diagram 12.
• Fit internal plastic flange (C) onto outer pipe. Push along the pipe until engaged against internal wall.
• From inside, insert inner pipe (D) into outer pipe.
• Fit both 'O' rings (E) into the flue elbow (F), one at the inlet, one at the outlet. By necessity, they are a loose fit, apply a small amount of silicone grease to each 'O' ring when fitting.
• Slacken the two screws and fit the clamp and seal
(G) onto the elbow.
• Take hold of the inner flue and push gently onto the elbow outlet taking care not to tear the 'O' ring.
Important: If the flue has been cut, ensure that there are no burrs that could damage the 'O' ring.
• Push the elbow clamp and seal over the outer flue.
• For flue systems less than 1 m long, leave the restrictor (a) fitted in the fan outlet, see diagram 13.
• Remove the backing from the self adhesive gasket
(H) and carefully fit gasket to base of flue elbow.
• Fit elbow onto boiler and secure with the four screws (I).
The standard flue kit 85090, see diagram 11, comprises :
- External rubber sealing collar...................................A
- Outer pipe..................................................................B
- Plastic flange..............................................................C
- Inner pipe....................................................................D
- 2 'O' rings....................................................................E
- Elbow...........................................................................F
- Clamp and seal.........................................................G
- Gasket.........................................................................H
- Four screws.................................................................I
Diagram
Concentric flue system
The maximum permissible length (L) for the concentric flue system is 3 m. For flue systems up to 1 m length, the restrictor (a), supplied fitted to the boiler inside the fan outlet, must be left in place. For longer flue systems, the restrictor must be removed.
For each flue elbow used, the maximum permissible length (L) must be reduced by |1 metre.
Restrictor (a) if L < 1 m
Diagram 13
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Marine directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16