Mini Shiki Sai Kan Wall Mounted Units

R410

Following the success and popularity of the Shiki Sai Kan, SANYO have developed a smaller version. Not only stylish, it offers exceptional energy-saving performance: COP up to 4.31.

• Cooling and heating down to -15°C

• The LED photocatalytic sterilisation function ensures excellent performance to combat odours, germs and bacteria

• Automatic sweep control

• Apatite ceramic filter

• Multi-functional remote control with built-in temperature sensor

• Clock with ON/OFF program timer

• Washable front panel

• Low noise levels: 22 dBA (Quiet mode)

• Night set back/economy mode function ensures silent and energy-saving cooling and heating

INVERTER HEAT PUMP

Model 96

Model 126

Performance

Cooling

Heating

Cooling

Heating

Capacity

kW

2.65

3.60

3.50

4.8

(0.9-3.6)

(0.9-4.9)

(0.9-3.6)

(0.9-5.9)

Power input

W

250-650-1040

250-650-1400

250-1090-1200 250-1165-1600

EER/COP

4.21

4.31

3.41

3.81

Energy class

AAAA

Running current/AMPs

A

3.3 (1.3-5.4)

4.0 (1.2-6.8)

4.8 (1.2-5.6)

5.8 (1.1-7.3)

Annual energy consumption (cooling)

kW

315

-

512.5

-

Power supply

Vph,Hz

230, I+N, 50 outdoor unit

Indoor Unit

SAP-KRV96EHDS

SAP-KRVI26EHDS

Air circulation (H) m3/h

480

480

500

500

Moisture removal

Litres/h

1.6

-

2.0

-

Sound power evel (H) dB(A)

56

56

57

57

Sound pressure level (Quiet/L/M/H) dB(A)

22/28/35/41

22/28/35/41

22/28/35/42

22/29/36/42

Dimensions (HxWxD)

mm

265x789x180

265x789x180

Net weight

kg

9.5

9.5

Outdoor Unit

SAP-CRV96EHDS

SAP-CRV96EHDS

Sound power level (H) dB(A)

63

64

65

66

Sound pressure level (H) dB(A)

45

46

47

48

Dimensions (HxWxD)

mm

565x790x265

565x790x265

Net weight

kg

36

36

Installation Data

Model 96

Model 126

Pipe size function/discharge

Inches

1/4, 3/8

1/4, 3/8

Max piping length

m

15

15

Max elevation difference. - O.U. - I.U.

m

7

7

Chargeless piping length

m

7.5

7.5

Amount of additional refrigerant

AMP

15

15

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

Simple elegant design with panels available in 4 colour choice options.

SPNDS(N) SPNOS(L]

SPN-DS(G) SPN DS(W]

ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 51 p.51
page 52 p.52
page 53 p.53
page 54 p.54
page 55 p.55
page 56 p.56
page 57 p.57
page 58 p.58
page 59 p.59
page 60 p.60
page 61 p.61
page 62 p.62
page 63 p.63
page 64 p.64
page 65 p.65
page 66 p.66
page 67 p.67
page 68 p.68
page 69 p.69
page 70 p.70
page 71 p.71
page 72 p.72
page 73 p.73
page 74 p.74
page 75 p.75
page 76 p.76
page 77 p.77
page 78 p.78
page 79 p.79
page 80 p.80
page 81 p.81
page 82 p.82
page 83 p.83
page 84 p.84
page 85 p.85
page 86 p.86
page 87 p.87
page 88 p.88
page 89 p.89
page 90 p.90
page 91 p.91
page 92 p.92
page 93 p.93
page 94 p.94
page 95 p.95
page 96 p.96
page 97 p.97
page 98 p.98
page 99 p.99
page 100 p.100
Pages:
1-50
51-100
101-112
pdf-page pdf ae En 2008-12-49-05