Mini Shiki Sai Kan Wall Mounted Units
R410
Following the success and popularity of the Shiki Sai Kan, SANYO have developed a smaller version. Not only stylish, it offers exceptional energy-saving performance: COP up to 4.31.
• Cooling and heating down to -15°C
• The LED photocatalytic sterilisation function ensures excellent performance to combat odours, germs and bacteria
• Automatic sweep control
• Apatite ceramic filter
• Multi-functional remote control with built-in temperature sensor
• Clock with ON/OFF program timer
• Washable front panel
• Low noise levels: 22 dBA (Quiet mode)
• Night set back/economy mode function ensures silent and energy-saving cooling and heating
INVERTER HEAT PUMP
| | | | Model 96 | | | Model 126 | |
| Performance | | Cooling | | Heating | Cooling | | Heating |
| Capacity | kW | 2.65 | | 3.60 | 3.50 | | 4.8 |
| (0.9-3.6) | | (0.9-4.9) | (0.9-3.6) | | (0.9-5.9) |
| Power input | W | 250-650-1040 | | 250-650-1400 | 250-1090-1200 250-1165-1600 |
| EER/COP | | 4.21 | | 4.31 | 3.41 | | 3.81 |
| Energy class | | AAAA |
| Running current/AMPs | A | 3.3 (1.3-5.4) | | 4.0 (1.2-6.8) | 4.8 (1.2-5.6) | | 5.8 (1.1-7.3) |
| Annual energy consumption (cooling) | kW | 315 | | - | 512.5 | | - |
| Power supply | Vph,Hz | | | 230, I+N, 50 outdoor unit | | |
| Indoor Unit | | SAP-KRV96EHDS | SAP-KRVI26EHDS |
| Air circulation (H) m3/h | 480 | | 480 | 500 | | 500 |
| Moisture removal | Litres/h | 1.6 | | - | 2.0 | | - |
| Sound power evel (H) dB(A) | 56 | | 56 | 57 | | 57 |
| Sound pressure level (Quiet/L/M/H) dB(A) | 22/28/35/41 | | 22/28/35/41 | 22/28/35/42 | | 22/29/36/42 |
| Dimensions (HxWxD) | mm | | 265x789x180 | | | 265x789x180 | |
| Net weight | kg | | 9.5 | | | 9.5 | |
| Outdoor Unit | | SAP-CRV96EHDS | SAP-CRV96EHDS |
| Sound power level (H) dB(A) | 63 | | 64 | 65 | | 66 |
| Sound pressure level (H) dB(A) | 45 | | 46 | 47 | | 48 |
| Dimensions (HxWxD) | mm | | 565x790x265 | | | 565x790x265 | |
| Net weight | kg | | 36 | | | 36 | |
| Installation Data | | Model 96 | Model 126 |
| Pipe size function/discharge | Inches | | 1/4, 3/8 | | | 1/4, 3/8 | |
| Max piping length | m | | 15 | | | 15 | |
| Max elevation difference. - O.U. - I.U. | m | | 7 | | | 7 | |
| Chargeless piping length | m | | 7.5 | | | 7.5 | |
| Amount of additional refrigerant | AMP | | 15 | | | 15 | |
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Simple elegant design with panels available in 4 colour choice options.
SPNDS(N) SPNOS(L]
SPN-DS(G) SPN DS(W]