fixed bolts - SADEV Classic - 15 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

Catalogue excerpts

FIXED BOLTS FIXED BOLTS :: Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 2.02 www.sadev.com - info@sadev.com SUMMARY Pages 2.03 >> 2.16 FIXED BOLTS :: Fixed bolt, countersunk head Ref: V 2001 > Page 2.03 Fixed bolt, countersunk head, for installation from the outside Ref: V 2002 > Page 2.05 Fixed bolt, cylindrical head, for installation from the outside Ref: V 2003 > Page 2.07 Fixed bolt, cylindrical head, for installation from the outside Ref: V 2004 > Page 2.09 Fixed bolt, cylindrical head Ref: V 2005 > Page 2.11 Fixed bolt, countersunk head Ref: V 2006 > Page 2.13 Fixed bolt, cylindrical head, Ø 50 mm Ref: V 2105 > Page 2.15

 Open the catalogue to page 1

FIXED BOLTS FIXED BOLTS :: Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 2.03 www.sadev.com - info@sadev.com Reference: V 2001 Designation: fixed bolt, countersunk head. Glass drilling: Typical application: Mounting Alternate product Vertical façade Yes Roof/canopy Possible R1003 - R1005 Guard rail Possible V2003 - see SADEV Decor *Blind access No R1008 - R1006 Sloped glazing Yes Dimensions: *Installation from the outside (no access to the structure). H validated by SADEV depending on availability. Available for glass thicknesses from 8 to 31.52 mm, for other thicknesses please consult...

 Open the catalogue to page 2

FIXED BOLTS FIXED BOLTS :: Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 2.04 www.sadev.com - info@sadev.com Reference: V 2001 Suggested mounting instruction: Insert parts No. 1/2 and 3 into the glass. Mount contact washer No. 4 and glass nut No. 5 and tighten to 20 Nm (15 ft-lb) for monolithic glass and 10 Nm (7.5 ft-lb) for laminated glass using SADEV tools ref. 758-11-60 and ref. CLE-DYN-072031. Mount nut No. 6 and washer No. 7. Insert the thread axle into the support with spacer E (available on request), see technical page. Adjust the depth. Mount washer No.7, lock washer No. 8, and...

 Open the catalogue to page 3

FIXED BOLTS FIXED BOLTS :: Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 2.05 www.sadev.com - info@sadev.com Reference: V 2002 Designation: fixed bolt, countersunk head, for installation from the outside. Glass drilling: Typical application: Mounting Alternate product Vertical facade Yes Roof/canopy No V2005 Guard rail Possible see SADEV Decor *Blind access Yes Sloped glazing Yes Dimensions: *Installation from the outside (no access to the structure). H validated by SADEV depending on availability. Available for glass thicknesses from 8 to 31.52 mm, for other thicknesses please consult...

 Open the catalogue to page 4

FIXED BOLTS FIXED BOLTS :: Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 2.06 www.sadev.com - info@sadev.com Reference: V 2002 Suggested mounting instruction: Insert parts No. 1 and 3 into the glass hole. Mount contact washer No. 4 and glass nut No. 5 and tighten to 20 Nm (15 ft-lb) for monolithic glass and 10 Nm (7.5 ft-lb) for laminated glass using SADEV tools ref. 758-11-60 and ref. CLE-DYN-072031. Mount into the support with bolt No. 2, tighten in function of the support with a 10 mm hex key. Mount cover cap No. 6 using SADEV tool ref. 758-11-60. SADEV recommends using thread locking...

 Open the catalogue to page 5

FIXED BOLTS FIXED BOLTS :: Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 2.07 www.sadev.com - info@sadev.com Reference: V 2003 Designation: fixed bolt, cylindrical head, for installation from the outside. Glass drilling: Typical application: Mounting Alternate product Vertical facade Yes Roof/canopy Possible V2005 Guard rail Yes see SADEV Decor *Blind access Yes Sloped glazing Yes Dimensions: *Installation from the outside (no access to the structure). H validated by SADEV depending on availability. Available for glass thicknesses from 8 to 31.52 mm, for other thicknesses please consult...

 Open the catalogue to page 6

FIXED BOLTS FIXED BOLTS :: Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 2.08 www.sadev.com - info@sadev.com Reference: V 2003 Suggested mounting instruction: A – Classic mounting Insert parts No. 2/3/4/5 into the glass hole. Mount the second contact washer No. 4, external plate No. 1, and bolt No. 9 and tighten to 20 Nm (15 ft-lb) for monolithic glass and 10 Nm (7.5 ft-lb) for laminated glass. Thread on nut No. 6 and apply washer No. 7. Insert the threaded axle into the support with spacer E (available on request), see technical page. Adjust the depth. Mount the second washer No. 7, lock...

 Open the catalogue to page 7

FIXED BOLTS FIXED BOLTS :: Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 2.09 www.sadev.com - info@sadev.com Reference: V 2004 Designation: fixed bolt, cylindrical head, for installation from the outside. Glass drilling: Typical application: Mounting Alternate product Vertical facade Yes Roof/canopy Yes Guard rail Possible see SADEV Decor *Blind access Yes Sloped glazing Yes Dimensions: *Installation from the outside (no access to the structure). H validated by SADEV depending on availability. Available for glass thicknesses from 8 to 31.52 mm, for other thicknesses please consult us. Monolithic...

 Open the catalogue to page 8

FIXED BOLTS FIXED BOLTS :: Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 2.10 www.sadev.com - info@sadev.com Reference: V 2004 Suggested mounting instruction: Insert parts No. 1, 4, and 3 into the glass hole. Mount the second contact washer No. 4 and glass nut No. 5 and tighten to 20 Nm (15 ft-lb) for monolithic glass and 10 Nm (7.5 ft-lb) for laminated glass using SADEV tools ref. 758-11-60 and ref. CLE-DYN-072031. Mount into the support with bolt No. 2, tighten in function of the support with a 10 mm hex key. Mount cover cap No. 6 using SADEV tool ref. 758-11-60. SADEV recommends using...

 Open the catalogue to page 9

FIXED BOLTS FIXED BOLTS :: Tel. +33 (0)4 50 08 39 00 - Fax +33 (0)4 50 08 39 49 2.11 www.sadev.com - info@sadev.com Reference: V 2005 Designation: fixed bolt, cylindrical head. Glass drilling: Typical application: Mounting Alternate product Vertical facade Yes Roof/canopy Yes Guard rail Yes see SADEV Decor *Blind access No V2003 Sloped glazing Yes Dimensions: *Installation from the outside (no access to the structure). H validated by SADEV depending on availability. Available for glass thicknesses from 8 to 31.52 mm, for other thicknesses please consult us. Monolithic glass Laminated glass V =...

 Open the catalogue to page 10

All SADEV catalogues and technical brochures

  1. SABCO

    2 Pages

    En
  2. Projects

    36 Pages

    En
  3. Rotules

    23 Pages

    En
  4. Fluido

    6 Pages

    En
  5. PIUMA

    4 Pages

    En
  6. Vertical Lock

    4 Pages

    En
  7. CLADDING SYSTEM

    4 Pages

    En
  8. CANOPIES

    8 Pages

    En
  9. SADEV DECOR

    36 Pages

    En

Archived catalogues

  1. svd canopies

    6 Pages

    En
  2. order form

    6 Pages

    En
  3. Portavant 60

    8 Pages

    En
  4. Shower system

    8 Pages

    En
  5. FLO

    4 Pages

    En
  6. NEWS 2013

    2 Pages

    En
  7. Brass & Aluminium

    36 Pages

    En
  8. Variamont

    12 Pages

    En
  9. Pivoting Door

    94 Pages

    En
  10. Door handle

    34 Pages

    En