Included in delivery
5 x PHÖNIX Infinity 2 (Duo 5) 6 x PHÖNIX K323 (Duo 6)
Collectors
Collector dimensions Collector weight Gross area
Effective absorber area Heat transfer medium capacity Absorber type Absorbency Optical efficiency Emissivity Efficiency factors Max. stagnation temperature Collector material
1,88 x 1,16 x 0,095 m (length x width x height) 2,16 x 1,16 x 0,095 m
38 kg 46 kg
2,18 m2 2,5 m2
2,0 m2 2,31 m2
1,13 litre 1,3 litre
Sunselect
95%
80% based on aperture area 5%
a1: 3,24 W/ m2 Ka2: 0,0161 W/ m2 K2 206 °C
Frame made from extruded aluminium profile with backside (50 mm rock wool) and sidewise insulation (20 mm rock wool) low-iron solar safety glass
Collector test report by ISFH Germany acc. to German Industry Norm (DIN) No. 4757 Part 4, test report No.: 16-00/D, type approval No. 03-228-733 by Senate of Berlin, Germany
Glass cover Test reports
Collector installation possibilities
Dimensions: Width x Length, including space for
connectors Alternatives:
Vacuum-tube collectors, CPC type with modern mirrors
flat roof mounting rig for alternatives 1 and 2 available
wall mounting rig
for alternatives 1 and 4
available
All alternatives possible with 4 collectors.
Alternative 2, Duo 5 (Infinity 2)
transverse horizontal array, single row (collector connectors alongside) dimensions of collector field: 9,4 x 1,31m
Alternative 1 (standard), Duo 5 (Infinity 2)
on edge horizontal array, single row dimensions of collector field: 5,80 x 2,03 m
Alternative 3, Duo 6 (K323)
collector area 15 m2 transverse vertical array, double garden column dimensions of collector field:
4,52 x 3,48 m
Alternative 4, Duo 6 (K323)
on edge horizontal array, double rows (package contains 4 roof ducts) dimensions of collector field: 3,48 x 4,62 m
Alternative 5, Duo 6 (K323)
on edge vertical array, double column
dimensions of collector field: 2,52 x 6,48 m
Alternative 6, Duo 6 (K323)
transverse horizontal array, double column (collector connectors alongside, package contains 4 roof ducts) dimensions of collector field: 6,48 x 2,62 m
Type K-500/200 V4A
800 litres, (600 litres heater water buffer and 200 litres tap water)
buffer: steel, outside primed
inner tap water buffer: stainless steel (1.4571)
buffer 3 bar, tap water 6 bar
2,0 m2
Storage capacity Material
Max. pressure
Surface area
tap water buffer Heat exchanger Connections inlet/outlet
tube heat exchanger 2 x 2,4 m2
heating system: 1" external thread with flat sealing screw joint,
hot and cold water: 3/4" external thread with flat sealing screw joint,
solar supply and return: 3/4" external thread with flat sealing screw joint
polyurethane foam 100 mm replaceable,
inspection tap on top, replaceable lid 180 mm, bottom 50 mm,
X = 0,037 W/mK
up to 2,3, depending on temperature sensor position
note: if tap water is to be provided for more than five people, a separate
calculation of N needs to be done
2,03 m x 0,99 m
0,79 m
2,00 m
280 kg incl. insulation
Insulation
Performance number NL
Dimensions with insulation
Diameter without insulation Dimension tilted Total weight