Text version of the page
INFOTEXT
OKATHERM Double Glazing Units
OKATHERM offers • very good thermal insulation • if required, thermal solar control through reduced total solar energy transmittance • If required, lower glare through reduced light transmission • a large number of colour and structural design options >
Technical Data
Heat insulation
A wide range of U-values can be realised with OKATHERM, in accordance with your requirements. The U-value depends on: • the number of cavities • the emissivity of the glass coating(s) • the filling of the cavity with air or gas With 2-pane build-ups, U-values from 1.0 W/(m²K) (0.18 Btu/hr/ft²/°F) can be achieved, with 3 panes 0.5 W/(m²K) (0.10 Btu/hr/ft²/°F) can be achieved. >
Sound insulation
The sound attenuation value of a glazing system depends in a complex way on • glass thicknesses and coatings in laminated glass • cavity • gas filling The figure of 36 dB for standard structures (6 mm glass /16 mm cavity/4 mm glass) can be increased to over 50 dB by means of suitable measures. >
Total solar energy transmittance and light transmission
The total solar energy transmittance or solar heat gain coefficient (TSET or s.h.g.c.) of a glazing system is the sum of • solar transmission • secondary heat transfer Solar transmission depends to a large extent on the coatings and types of glass involved. Secondary heat transfer also depends on the position of the coating. The light transmission of a glazing system depends to a large extent on >
OKALUX GmbH 97828 Marktheidenfeld Germany Tel.: +49 (0) 9391 900-0 Fax: +49 (0) 9391 900-100 www.okalux.com info@okalux.de Infotext Okatherm engl 20.06.2007 1 (5)