""Everything is for air, “that isn't visible but is perceivable”. To have the control of this noble fluid is the aim of our intuitions.”

 Open the catalogue to page 3

Domestic & Utility INDEX Axial Fans Axial Window Fans Centrifugal Fans

 Open the catalogue to page 4

Domestic & Utility Hand Dryers AIRPOWER ANTIVANDALO Hair Dryers PHONNY TUBO PHONNY MURO Ceiling Fans Accessories Domestic+Utility

 Open the catalogue to page 5

Operating indicator light O Ball bearing motor ^ Low profile £ Energy saving sr Low noise level (jl^ No dust on the wall (outlet) Washable filter ^ IPX5 protected ||<) Backdraught shutter ^ High technology engine Antivandal ^ Makes the air healthier Removes moisture amd mould |T^ no dust on the wall (inlet) Wi-Fi ♦"I* Operation granted up to +70°C | Internal shutter •ft Oriented air outlet Rotating body ^ Double inlet In line air outlet or at 90° CHARATERISTICS BB    ball bearing motor HT    humidistat with timer PIR    passive infrared sensor SELV    safety extra low voltage (12 V) C € The product...

 Open the catalogue to page 7

Domestic & Utility TECHNICAL GUIDE VENTILATING THE ROOMS The air quality in confined spaces (indoor), can cause different unpleasant effects reactions from general malaise to more serious complications on health status. Experts have widely shown that huge concentrations of pollutants like tobacco, smoke, sweat, formaldehyde, carbon monoxide (CO2), radon, etc... can be found in work environments, in public offices, commercial buildings. To improve the quality of air we breath, it is necessary to ventilate the rooms where people live and carry out their several activities. Hence the need to install...

 Open the catalogue to page 8

Rooms’ category Air flow rate Ref. No. People    I Ref. m2 air changes per person I air changes per m2 I/s    | m3/h I/s    | m3/h Ref. Volume air changes per hour Residential Buildings houses    Bedrooms, Living rooms    11 Kitchens, Bathrooms, Services Meeting rooms    9 Kitchens, Bathrooms, Services Bathrooms, Services Hall, Living rooms    11 Data processing center    7 Medical rooms, living room    8,5 Services public buildings cinema theaters,    Public areas, rooms (no smoking)5,5 conference halls    Stages, TV studio    12,5 Meeting rooms (smokers)    10 Waiting rooms museums, libraries    Exhibition...

 Open the catalogue to page 9

1) Start with the flow rate value (m3/h) on the right side of the diagram. 2) Proceed horizontally until you cross the diagonal line giving you the diameter of the duct you need. 3) Descend vertically to find the value of the pressure loss expressed in mm H2O per each meter of duct. Multiply this value with the required length of pipe and you will find the total pressure loss value. If you want the value in Pa, multiply the value by 9,81. 4) At the intersection of the flow rate and duct diameter values, follow this line upwards until it intersects with the recommended air speed (m/sec). Once you...

 Open the catalogue to page 10

O.Erre via del Commercio 1 - 25039 Travagliato CBS) 9

 Open the catalogue to page 11

IN AXIAL FAN • Axial fans to extract air directly outside or through short ducting also suitable for glass application with optional glass kit; • Low profile grille with operating indicator light; • Two fixing screws and click assembly of the grille for easy installation; • Double insulated product, without ground wire for fast connection; • For ducts 0 92-100-125-150 mm; • Base, Timer, HT, PIR, 12V model options; • Reduced internal wall dimensions to allow installation where the bend of ducting is close to the outlet of the product; A version: internal, silent automatic shutter; BB versione:...

 Open the catalogue to page 12

Flow rate FURTHER INFORMATION... IN • Timer version: Turn-off delay adjustable from 2 to 25 minutes; • HT version: The fan automatically starts when the humidity in the room is higher than the preset value, adjustable from 40% to 90%; • PIR version: The fan automatically starts when the sensor detects a presence in the room. When the room is vacated the fan will continue to run according to the preset value on timer; • Careful selection of materials: grille in ABS and body in polypropylene talc filled; • Performance tests in accordance with Standard UNI 10531, noise tests in accordance with Standard...

 Open the catalogue to page 13

Timer version supplied with Timermatic integrated; IPX4 protected (EN 60529); In accordance with Standard EN 60335-2-80. STANDARD 8 AXIAL FAN • Axial fans to extract air directly outside or through short ducting; • Double insulated product, without ground wire for fast connection; • For ducts 0 80-100 mm; • Base, Timer, Pull cord model options; - Wall monuting - Ceiling mounting Timertronic Timermatic O.Erre via del Commercio 1 - 25039 Travagliato CBS) 9

 Open the catalogue to page 15

UNICO 15/6” 214 214 66 26 150 7 *column F only for C version Axial fans to extract air directly outside or through short ducting; Operating indicator light on all models (except for UNICO 9/3,5”); Two fixing screws and click assembly of the grille for an easy installation; For ducts Ø 92-100-120-150 mm; Versions: Base, Timer, HT, PIR, Pull Cord and 12 V; High performances, low sound level and low power consumption; IPX4 protected (EN 60529); 45° C working temperature; C version: backdraught shutter; BB version: long life ball bearing motor; SELV 12V version: working at 12V AC. Installation within...

 Open the catalogue to page 16

FLOW CHARTS • UNICO 10/4” flow rate flow rate flow rate flow rate Sensor UNICO

 Open the catalogue to page 17

New cover design; Axial fans to extract air directly outside or through short ducting; Operating indicator light on all models; Click assembly of the grille and of the cover; Long life ball bearing motor; Backdraught shutter; Two fixing screws for an easy installation; For ducts Ø 100-120-150 mm; Versions: Base, Timer, HT; High performances, low sound level and low power consumption; 45° C working temperature; IPX4 protected (EN 60529); In accordance with Standard EN 60335-2-80. POSITIONING - Wall mounting - Ceiling mounting TECHNICAL DATA Model Flow rate (m3/h) with shutter without shutter FLOW...

 Open the catalogue to page 18

• ALBA 15/6” with shutter • ALBA 15/6” without shutter flow rate Sensor ALBA