NIBE™ F2030 - 1

NIBE™ F2030 AIR/WATER HEAT PUMP STRONG AS A VIKING. • Efficient scroll compressor that operates at temperatures down to -25°C. • The compressor uses EVI technology, which means improved performance in both hot and cold weather conditions. • Manufactured in two sizes: 7 and 9 kW. • High temperature range: – upply temperature max 65 °C (down to -10 °C) S linear to 63 °C (from -10 °C to -25 °C) – eturn line temperature 55 °C R • Automatic 2-step capacity regulator for the fan and compressor. • Integrated condensation water trough that together with condensation water pipe KVR 10 prevents icing. • Integrated intelligent control for optimum control of the heat pump. F2030 is started by a start signal from the NIBE indoor module or thermostat. • The material has a long service life and is designed to withstand the Nordic outdoor conditions. • F2030 can also be used together with most electric boilers, oil boilers or similar. • F2030 can be controlled from a specially designed controller, SMO. SMO connects and disconnects the additional heat and controls switching between room heating and hot water heating. • F2030 can also be docked to indoor unit VVM 310, VVM 320 or VVM 500 (accessory). VVM 310/VVM 320/VVM 500 contains controls and consists of a water heater and additional heater in the form of an electric boiler. F2030 together with VVM 310, VVM 320 or VVM 500 make up a complete heating installation. NIBE F2030 NIBE™ F2030 is an air/water heat pump, specially designed for the Nordic climate. F2030 utilises the outside air so there is no need for bore holes or coils in the ground. F2030 is designed to be docked to water borne heating systems. Please visit ww

Open the catalog to page 1
NIBE™ F2030 - 2

GOOD TO KNOW ABOUT NIBE™ F2030 Principle of operation This is a simplified version of how it works. The outdoor air is drawn into the heat pump and meets a closed system. The system contains a refrigerant with the capacity to turn into gas at a very low temperature. F2030 is equipped with control and monitoring equipment, however some exterior maintenance is still necessary. Under high pressure, a compressor considerably increases the temperature of the refrigerant, which is now gaseous. Then, using a condenser, the heat is transferred to the house’s heating system, while at the same time...

Open the catalog to page 2
NIBE™ F2030 - 3

GOOD TO KNOW ABOUT NIBE™ F2030 Transport and storage F2030 should be transported and stored vertically. Control F2030 is equipped with an integrated electronic controller that handles all functions necessary for heat pump operations. Accordingly, defrosting, stop at max/min temperature, connection of the compressor heater as well as enabling the heater for the drip pan, monitoring of motor protection and pressure switches are controlled. The number of starts and the operating time can also be read. The integrated controller is set during installation and can be used during a service. Under...

Open the catalog to page 3
NIBE™ F2030 - 4

GOOD TO KNOW ABOUT NIBE™ F2030 Equipment QN1

Open the catalog to page 4
NIBE™ F2030 - 5

GOOD TO KNOW ABOUT NIBE™ F2030 List of components Drip tray heater Pipe connections Cone heater Connector, heating medium out of F2030, G1 (28 mm) Fuse for external heating cable (250 mA) Connector, heating medium in to F2030, G1 (Ø28 mm) Service connection, high pressure Motor circuit breaker Service connection, low pressure Connection, drip tray drain (Ø40 mm) QA51 Contactor, main contactor X1 Terminal block, incoming supply Terminal block, charge pump, external heater High pressure pressostat (29 bar) Terminal block, buzzer alarm High pressure pressostat (32 bar) X5 Terminal block,...

Open the catalog to page 5
NIBE™ F2030 - 6

GOOD TO KNOW ABOUT NIBE™ F2030 1260 There should be a minimum of 350 mm free space behind the heat pump for service work. Leave a space of about 600 mm to the right of the heat pump for servicing. An area of 1000 mm is required in front of and above the heat pump for service work.

Open the catalog to page 6
NIBE™ F2030 - 7

INSTALLATION F2030 can be installed in several different ways, for example with integrated out external control. The safety equipment must be installed in accordance with current regulations for all docking options. Docking NIBE F2030 + NIBE SMO 05 / SMO 20 system When docking with F2030 a minimum available system volume of at least 20 litres water per kW output on the heat pump is recommended. SMO 05 is a modern, simple control module that, together with a NIBE air/water heat pump NIBE F2030, a water heater and an auxiliary heat source, creates a complete installation. Inspection of the...

Open the catalog to page 7
NIBE™ F2030 - 8

INSTALLATION NIBE F2030 + NIBE SMO 40 system Hot water control VST 11 (Accessory) SMO is an intelligent control module that, together with, F2030 and existing heating and hot water equipment, creates a complete unit. SMO manages compressor operation in F2030 and, if necessary, the additional power from any type of existing equipment that may be required. This accessory allows the heat pump F2030 with SMO to prioritise hot water charging on systems with floating condensing. This also requires a hot water accumulator, for example, NIBE VPA or NIBE VPB as well as a thermostat. When the hot...

Open the catalog to page 8
NIBE™ F2030 - 9

INSTALLATION Installation area Lifting from the street to the installation location The distance between F2030 and the house wall must be at least 350 mm. Clearance above F2030 must be at least one metre. If the surface allows, the simplest thing is to use a pallet truck to move F2030 to the installation area. The centre of gravity is offset to one side (see print on packaging). Free space behind Fritt utrymme bakom Minimalt Minutrymme free fritt space Fritt in front Free spaceutrymme framför 600 mm mm 600 Min. avstånd Min free space vid användning av flera F2030 when several F2030 Minimalt...

Open the catalog to page 9
NIBE™ F2030 - 10

INSTALLATION Pipe installation Condensation water collection Pipe installation must be carried out in accordance with current norms and directives. F2030 works up to a return temperature of approximately 55 °C and an outgoing temperature from the heat pump of approximately 65 °C. When F2030 is not equipped with shutoff valves on the water side these must be fitted to facilitate future service. The integrated condensation water trough is used to collect and lead away most of the condensation water from the heat pump. The condensation water (up to 50 litres/24 hrs) collected in the trough...

Open the catalog to page 10

All NIBE Energy Systems catalogs and technical brochures

  1. F1255

    20 Pages

  2. NIBE™ F470

    16 Pages

  3. NIBE™ F370

    16 Pages

  4. EMINENT

    2 Pages

  5. F1345

    28 Pages

  6. F1255

    22 Pages

  7. F1155

    22 Pages

  8. nibe

    32 Pages

  9. NIBE™ F2300

    32 Pages

  10. F2026

    4 Pages

  11. NIBE™ F2016

    32 Pages

Archived catalogs